Laserfiche WebLink
RETURN AC U � AH U - H EAT I N G FULL SIZE AS DRAIN PAN OUTLET <br />� - RETURN � DRAW-THROUGH COIL <br /> UNION SLOPE PIPING TO DISCHARGE <br /> DOUBLE WALL INSULATED POINT(TYP). <br /> STAINLESS STEEL,ASHRAE <br /> SUPPLY SUPPLY COMPLIANT DRAIN PAN �� o GAP�(TYP)M AIR <br /> � <br /> / / NC SEE PLUMBING SHEETS FOR <br /> / / SANITARY DRAIN FIXTURE <br /> UNIT INTEGRAL AND LOCATION <br /> BASE RAIL <br /> � - <br /> MULTIPLE COIL �I � 2-1/2" GALVANIZED ANGLE, WELDED AT CORNERS, <br />� 1 FASTENED AND CAULKED TO PAD TO FORM A <br /> UNION WATERTIGHT EMERGENCY DRAIN PAN - <br /> ql � �I CLEAN OUT CAPS <br /> AIRFLOW �I �� b AIRFLOW �� I � A�U - COOLING ACU - COOLING <br /> J � BLOW-THROUGH COIL 1/4" DIAMETER HOLE DRAW-THROUGH COIL FULL SIZE AS DRAIN PAN OUTLET <br /> J DOUBLE WALL INSULATED UNION <br /> STAINLESS STEEL,ASHRAE SLOPE PIPING TO DISCHARGE DOUBLE WALL INSULATED <br /> COMPLIANT DRAIN PAN POINT TYP STAINLESS STEEL,ASHRAE CLEAN OUT CAPS <br /> � FLEX � �� COMPLIANT DRAIN PAN _ <br /> FLEX CONNECTION AHU o � HO�LE IIN TOP <br /> 5 CONNECTION TYPICAL � J � �� � OF THIS CAP SLOPE PIPING TO DISCHARGE <br />� TYPICAL � r POINT(TYP). <br /> 4 -L <br /> 0 <br /> SINGLE COIL SECTION PIPING ISOMETRIC DOUBLE COIL SECTION PIPING ISOMETRIC ° <br /> UNIT WTEGRAL � 4 UNIT INTEGRAL � �--� —i 2" MINIMUM <br /> BASE RAIL 2 MINIMUM BASE RAIL AIR GAP <br /> NTS FCUs,AND BCUs NTS ACU-02,ACU-07,ACU-10, ACU-16 � AIR GAP (TYP) <br /> (TYP) <br /> 4 <br /> 2-1/2° GALVANIZED ANGLE, WELDED AT CORNERS, 2-1/2" GALVANIZED ANGLE, WELDED AT CORNERS, SUPPORT PIPING (TYP) <br /> FASTENED AND CAULKED TO PAD TO FORM A FASTENED AND CAULKED TO PAD TO FORM A • <br /> STAGGERED COIL RETURN WATERTIGHT EMERGENCY DRAIN PAN 1 WATERTIGHT EMERGENCY DRAIN PAN SEE PLUMBING SHEETS FOR <br />� SECTIONS SUPPORT PIPING (TYP) SANITARY DRAIN FIXTURE <br /> AND LOCATION <br /> SEE PLUMBING SHEETS FOR <br /> � SUPPLY SANITARY DRAIN FIXTURE NOTES: <br /> , AND LOCATION <br /> 1. SEE SPECIFICATIONS FOR CONDENSATE PIPING MATERIAL. <br /> � 2. MINIMUM SIZE OF CONDENSATE PIPING SHALL BE 1-1/4". <br /> RETURN � � 3. INSULATE CONDENSATE PIPING PER SPECIFICATIONS. <br /> / <br /> 4. PROVIDE FLOAT SWITCH IN EMERGENCY DRAIN PAN. <br /> S�PP�Y `�I ' ACU i AHU COIL DRAIN TRAP DETAIL <br /> � MULTIPLE COIL �1 I NTS � <br />� �I � � � <br /> / � <br /> MULTIPLE COIL <br /> 16" BOILER FLUE <br /> � RETURN VENT THRU <br /> �I � ROOF <br /> �I I � SUPPLY 10" COMBUSTION <br /> � AIR VENT THRU <br /> AIRFLOW � , EXTERIOR WALL <br /> . <br /> � � <br /> � �I � � � I 10" HHWS � <br /> AIRFLOW ( � J '� � <br /> � � � � 10" HHWR <br />� � c�l 6�� HHWR � <br /> FLEX CONNECTION � AIRFLOW c�l I , � 6° HHWS <br /> TYPICAL <br /> ` <br /> FLEX I � <br /> � CONNECTION � b <br /> TYPICAL � <br /> FLEX HOSE-TYPICAL 1" PRESSURE � � <br /> TRIPLE COIL SECTION PIPING ISOMETRIC 6 STAGGERED COIL SECTION PIPING ISOMETRIC RELIEFVA TO - <br /> DRAW <br /> NTS ACU-03, ACU-06, ACU-12,ACU-15,ACU-18 NTS OADACUs, ACU-01 ACU-04,ACU-05, ACU-Q8, ACU-09, ACU-'11, ACU-13, U N I T H EAT E R WAT E R C O I L � <br /> ACU-14,ACU-17,ACU-19,ACU-20 CHW, ACU-21 THRU ACU-27 <br />' PIPING ISOMETRIC <br /> RETURN <br /> STAGGERED COIL <br /> NTS WITH FL,OW CONTROL VALVE <br /> 1-1/2" DRAIN <br /> SECTIONS <br /> � � � . <br /> SUPPLY I <br /> / <br /> � RETURN U <br /> G� NOTES: FLEX HOSE-TYPICAL y� � � � <br /> / ` V <br /> � 1. USE UNION FOR PIPING 2"OR SMALLER, FLANGE ON PIPING 2-1/2" OR LARGER- 4" CONCRETE ' <br /> TYPICAL. HOUSEKEEPING <br /> � PAD <br />� 2. POSITION UNIONS (OR FLANGES)TO ALLOW FOR COIL REMOVAL. ' SUPPLY <br /> . <br /> �j 3/4" PVC DRAIN TO <br /> MULTIPLE COIL �I � 3. USE BALL fSOLATION VALVE FOR PIPES 2"AND SMALLER. USE BUTTERFLY ISOLATION CONDENSATE <br /> VALVES FOR PIPES 2 1/2"AND LARGER. I NEUTRALIZATION <br /> TANK <br /> 4. IF UNIT IS EXTERNALLY ISOLATED, USE FLEX CONNECTORS ON SUPPLY AND RETURN �,�I� <br /> PIPE TIE-INS. 1. VERIFY SUPPLY/RETURN ORIENTATION ON BOILER. <br /> � I ' 2. PROVIDE EACH BOILER WITH ITS OWN CONDENSATION NEUTRALIZATION TANK, <br /> �� , 5. PROVIDE WITH PRESSURE INDEPENDENT CONTROL VALVE, UNO. AIRFLOW LOCATED UNDER ITS SUPPORT STAND. <br /> ��I . 3. LEVEL BOILER. , <br /> a 6. PROVIDE EITHER UNION OR FLANGES ON BOTH SIDES OF CONTROL VALVE FOR 4. MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCES, <br /> � MAINTENANCE. INCLUDING ABOVE BOILER FOR BURNER ACCESS. ' <br />+ AIRFLOW � I \ I 7. CONNECT BRANCH PIPING TO TOP C?F HEADER. CO N D E N S I N G BO I L E R D ETAI L <br /> � � b � 8. POSITION STRAINER BLOWDOWN VALVE AND CONTROL VALVE A MAXIMUM OF 6'-0" S <br /> � NT <br /> J AFF. <br /> � 9. TEST PORTS MAY BE ELIMINATED IN PIPING IF lNCLUDED IN EQUIVALENT POSITION � <br /> � ON DEVICES (PICVs, ETC). <br /> F�EX�oNNE�T,oN �'°�. TE RM ! NAL �VAV B OX) WATE R <br /> TYP'�A` COIL PIPING ISOMETRIC Core & Shell <br /> NTS WITH FLOW CONTROL VALVE � ' ' <br /> ,F�NG C�n1 <br /> �-� G �� V�ASy��F� <br />, �4) STAGGERED COIL SECTION PIPING ISOMETRIC COIL ISOMETRIC NOTES �a � ` � �' ; r. �� � <br /> NTS 09� � <br /> G <br /> ACU-18, ACU-20 HHW NTS �^ � <br /> �� <br /> 90C1 SW 16th Street Suite 307 ���'FS 'rc� � ���r,��� <br /> Renton, Washington 98057 s�ON� ! ��`�' <br /> � <br /> o.. <br /> W A S ACCEPTABILtTY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL pATE � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE p4 N RAN 01/15/16 HVAC DETAILS � <br /> 0 Issue For Construction RAN JLC 12I05114 5 Revision-Release 20 RAN JLC 06/16115 ,�P'�� ��o THIS DESIGN AND/OR CHECKED W2�H3�7 01l15/16 M <br /> JLC 01115l16 SHEET � <br /> 5 � SPECIFICATION IS APPROVED " <br /> 1 Revision-Release 3 RAN JLC 12119114 6 Revision-Release 34 RAN JLC 01115I16 � BRPHARCHITECTS ENGINEER TITLE � <br /> BOE,�� ENGINEERSWC. APPROVED BY DEPT. DATE JLC 01115l16 Boeing 777X CWC BUILDING G o <br /> 2 Revision-Release 11 (Sheil&Core Pkg) RAN JLC O3IO3I�I5 N03137 CHECKED I`/I J O 0 �- <br />� m�' = APPROVED � <br /> 3 Revision-Release 15 RAN JLC 04lO7l15 �,� �o B U I L D I N G 4 0'�J V JOB NO. Y coMP No. z <br /> /cqTF OF AUZ���\�P APPROVED ow�No. 40-5&M500 � <br /> 4 Revision-Release 17 RAN ,1LC 05I05115 MECHANICAL MASTER EVERETT,WA 40-58-M500 - <br />