STRUCTURAL DESIGN CRITERIA: A , „ L <br /> 1250 -0 <br /> 1. DESIGN IS BASED ON THE INTERNATIONAL BUILDING CODE 2012 AND BOEING REQUIREMENTS. ��-���� 200'-0" , 852'-0" , 200'-0" 1'-0° . <br /> 15. DESIGN EARTHQUAKE: REFERENCE-ASCE 7-10 FR M INSIDE FACE OF PARAPET FROM INSIDE FACE OF PA PET <br /> 2, ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH PROJECT DRAWINGS AND SPECIFICATIONS RISK CATEGORY _ _ - - T - - - - - - - - - - _ _ II <br />� IMPORTANCE FACTOR I seismic - - - - - _ - - - - - - 1.25(OWNER REQUESTED VOLUNTARY INCREASE) o <br /> 3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS,CONNECTIONS, EMBED PLATE AND ANCHOR BOLT LOCATIONS 0.2 SECOND MAPPED ACCELERATION Ss 1.450 � a <br /> FROM EQUIPMENT MANUFACTURER'S APPROVED DRAWINGS AND STEEL FABRICATOR'S ANCHOR BOLT AND ' - - - - - - - - - � � <br /> EMBED PLATE SETTING PLANS,WHICH HAVE BEEN APPROVED BY THE ARCHITECT/ENGINEER. 1.0 SECOND MAPPED ACCELERATION,S1 - - - - - - - - - 0.563 �� � <br /> 4• THE CONTRACTOR SHALL WORK STRUCTURAL DRAWINGS TOGETHER WITH ARCHITECTURAL, MECHANICAL, 0.2 SECOND DESIGN ACCELERATION, Sds_ _ _ _ _ _ _ _ _ 0.967 _ p � � <br /> �L/ � <br /> PLUMBING, ELECTRICAL AND CIVIL DRAWINGS TO LOCATE DEPRESSED SLABS,SLOPES, DRAINS, REGLETS, BOLT 1.0 SECOND DESIGN ACCELERATIpN, Sd1_ _ _ _ _ _ _ _ _ 0.563 o Q � - <br /> SETTINGS,GRADES, ETC.ANY DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECTIENGINEER � � <br /> BEFORE PROCEEDING WITH THE WORK. SITE CLASS - - - - - - - - � - - - - - - - - - D `V wo <br /> SEISMIC DEStGN CATEGORY_ _ - - - - __ � _ - _ _ _ D Z � <br /> 5. THE CONTRACTOR SHALL REVIEW THESE DRAWINGS AND V1SIT THE PROJECT SITE BEFORE CONSTRUCTION BEGINS TO - . <br /> COMPARE ALL EXISTING CONDITIONS AND DIMENSfONS WITH WHAT IS SHOWN ON THESE DRAWINGS. IF THERE ARE LATERAL SEISMIC RESISTING SYSTEM CRITERIA(STEEL BUCKLING RESTRAINED BRACED FRAMES) � <br /> CONDITIONS WHICH ARE DIFFERENT FROM WHAT IS SHOWN,THE STRUCTURAL ENGINEER OF RECORD SHALL BE SEISMIC DESIGN COEFFICIENT, Cs_ _ _ _ _ _ _ _ _ 0.063 "- <br /> NOTIFIED. DESIGN BASE SHEAR, Qe - __ - T - _ - - - 5,800 KIPS 99 7 99 7 <br />� RESPONSE MODIFICATION COEFFICIENT, R _ - - - - - _ 8 <br /> 6. THE CONTRACTOR SHALL ARRANGE A PRE-CONSTRUCTION MEETING WITH THE ARCH�TECT/ENGINEER TO ENSURE THAT <br /> THE CONTRACTOR'S UNDERSTANDING OF THESE DRAWINGS AND PLAN FOR THE WORK IS IN ACCORDANCE WITH THE DEFLECTION AMPLIFICATION FACTOR,Cd- - - - -. - - 5 <br /> DESIGN INTENT AND TO CLARIFY ANY QUESTIONS THAT THE CONTRACTOR MAY HAVE. SYSTEM OVERSTRENGTH FACTOR, �20 - - - - - __ - - 2.5 <br /> 7, ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED LONGITUDINAL SEISMIC RESISTING SYSTEM CRITERIA(STEEL BUCKLING RESTRAINED BRACED FRAMES) �, <br /> TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SEISMIC DESIGN COEFFICIENT, Cs- _- .- - - - - - - 0.063 � � C� �� � <br /> SHOWN. DESIGN BASE SHEAR,Qe_ _ _ _ _ ^ _ _ _ _ _ - 5,800 KIPS � <br /> 8. ROOF GRAVITY LOADINGS RESPONSE MODIFICATION COEFFICIENT, R_ _ _ _ _ _ _ 8 <br /> LIVE LOAD MINIMUM(NOT REDUCED) _ - _ _ - _ - - - _ 20 PSF DEFLECAT�ON AMPLIFICATION FACTOR,Cd _ - - - - - _ 5 ' <br /> DEAD LOADS: SYSTEM OVERSTRENGTH FACTOR,�lo_ � _ _ - _ 2.5 <br />,� SINGLE PLY ROOFING&INSULATION _ - - - - - _ _ 3.0 PSF SEISMIC LOAD RESISTING SYSTEM <br /> METAL DECK _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3.0 PSF THE SYSTEM CONSISTS OF A STEEL FRAMED ROOF, METAL DECK DIAPHRAGM,AND <br /> HANGING LOADS(MEP-JOISTS&BEAMS) _ _ _ _ _ _ _ 5.0 PSF STEEL BUCKLING RESTRAINED BRACED FRAMES.COLUMNS ARE SUPPORTED BY PILE CAPS AND � <br /> HANGING LOADS(MEP-TRUSSES) _ _ _ _ _ _ _ _ _ 3.0 PSF DRILLED PIER DEEP FOUNDATIONS. SLABS-ON-GRADE ARE SOIL SUPPORTED. _q� <br /> FRAMWG WEIGHTS(JOISTS)_ _ _ _ _ _ _ _ _ _ _ _ 3.0 PSF ANALYSIS PROCEDURE n- <br /> � <br /> FRAMWG WEIGHTS(SWAY TRUSSES) _ , _ � _ _ _ _ _ 6.0 PSF THE SEISMIC DESIGN STORY SHEAR,Vx,SHALL BE DISTRIBUTED TO THE VARIOUS VERTICAL o <br /> FRAMING WEIGHTS(MAlN TRUSSES)- _ _ - - - - - - 18.0 PSF ELEMENTS OF THE SEISMIC RESISTING SYSTEM IN THE STORY UNDER CONSIDERATION BASED o � � <br /> SPECIAL LOADINGS: ON THE RELATIVE LATERAL STIFFNESS OF THE VERTICAL RESISTING ELEMENTS AND THE N w � - � <br /> TRUSS BOTTOM CHORDS,CONCENTRATED LOAD 5,000 POUNDS DIAPHRAGM.THIS STRUCTURE IS DESIGNED FOR A BASE SHEAR CONSISTENT WITH ITS ABILITY Z ``3J � �� �J/ <br /> ROOF JOISTS,TWO BOTTOM CHORD PANEL POINT LOADS _ _ 2,000 POUNDS EACH TO DISSIPATE ENERGY BY INELASTIC CYCLIC STRAINING,THE MODAL RESPONCE SPECTRUM - <br /> ANALYSIS PROCEDURE WAS USED. � a � I I <br />� 9. DESIGN SNOW LOAD: REFERENCE - ASCE 7-10 r <br /> RISK CATEGORY - - - - - - - - - - - - - - - II 16. ALL ARCHITECTURAL,MECHANICAL,OR ELECTRICAL COMPONENTS AND THEIR ANCHORAGES TO THE <br /> GROUND SNOW LOAD, Pg - - - - - - - - - - 20.0 PSF STRUCTURE,WHETHER REQUIRED TO BE DESIGNATED SEISMIC SYSTEM OR NOT,SHALL BE DES�GNED <br /> FLAT ROOF SNOW LOAD, Pf - - - - - - 14.0 PSF IN ACCORDANCE WITH ASCE 7,CHAPTER 13,"SEISMIC DESIGN REQUIREMENTS FOR NONSTRUCTURAL C O M P O N E N T & C LA D D I N G W I N D L OA D <br /> EXPOSURE FACTOR,Ce - - - T - - - - - - - - - 1.0 COMPONENTS",AND INSPECTED AND TESTED AS REQUIRED IN ACCORDANCE WITH IBC 2012 AND <br /> IMPORTANCE FACTOR: I snow - - - - - - - - - - - - 1.0(1.1 FOR FACTORY MUTUAL COMPONENTS) ROO F ZO N E D IAG RAM - P LAN <br /> THERMAL FACTOR,Ct - - - - - - - - - - - - - 1.0 ASCE 7-10 CHAPTER 13.THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF THE ' <br /> RAIN ON SNOW(ROS)SURCHARGE - - - - - - - - - - 5.0 PSF DESIGN OF THE PARTICULAR COMPONENTS SHALL INCLUDE ALL DETAILS REQUIRED FOR THE <br /> DESIGN SNOW LOAD, Pb(PER RECOMMENDATI�NS FROM SEAOIN)- 25.Q PSF <br /> INSTALLATION ON THEIR DRAWINGS. • <br /> �o. E�EvaTE�F�ooR�oa�i�v�s - COMPONENT&CLADDING ULTIMATE ROOF WIND PRESSURE (PSF) SCHEDULE <br />� LIVE LOADS;OFFICE AND MECHANICAL FLOORS; TR�BUTARY ARE,4(sF� <br /> BASIC UNIFORM(COLUMNS AND FOOTWGS) 90 PSF " <br /> FRAMING UNIFORM(BEAMS AND GIRDERS) - - - - - - 150 PSF 100'-0" 100'-0" ZONE <br /> 10 ZO 50 100 200 �00 <br /> NON-CONCURRENT CONCENTRATED - - - - - - - - 3,OQ0 POUNDS <br /> NON-CONCURRENT FORK TRUCK - - - - - - - - - 10,000 LB AXLE � i �1 -54,7 •52,0 -48.1 -44.9 �42.1 -�.3 <br /> DEAD LOADS:OFFICE AND MECHANICAL FLOORS ,.._ w �2 -85.9 -81.6 -75.6 -70.4 �66.1 �0.1 <br /> CONCRETE ON METAL DECK - - - - - - - - 51 PSF a ¢ � �, `-r , <br /> - - - �q � �j) �L�� �� O3 -117.0 •111.2 -103.0 -95.9 -90.1 -81.9 <br /> FRAMING - - - - - - - - - - - - - - 15PSF B4O.D.VARIES a = � <br /> HANGING(MEP AND SPRINKLERS) - - - - - - - - - 14 PSF - <br /> � , <br /> I <br /> 11. CATWALK LOADINGS � <br />� LIVE LOADS: � <br /> UNIFORM - - - - - - - - - - - - - - - - - 50 PSF <br /> NON-CONCURRENT CONCENTRATED - - - - - - - - - 300 POUNDS <br /> DEAD LOADS- � <br /> , <br /> - - - - - - - -- - - - - - - - - - 15 PSF \�! �4) �� <br /> 12. STAIR LOADINGS � <br /> \ / <br /> LIVE LOADS: � <br /> UNIF�RM - - - - - - - - - - - - - - - - - 100 PSF <br /> NON-CONCURRENT CONCENTRATED - - - - - - - - 300 POUNDS � � _ � � . <br /> DEADLOADS - - - - - - - - - - - - - - 40PSF � P1 P2 ► P1 � P3 --- <br /> TOP OF RAILS UNIFORM - - - - - - - - - - - 50 PLF - � <br /> 1 <br /> TOP OF RAILS CONCENTRATED - - - - - - - - - - - 200 POUNDS � � � <br /> 13. CRANE LOADING(SEE CRANE FRAMING AND LAYOUT PLANS) � � ` <br /> 14. DESIGN WIND LOAD: REFERENCE - ASCE 7-10 C O M P O N E N T & C LA D D I N G W I N D LOAD � � <br /> R'SK�ATE�°RY - -- - - - - - -- - - - - - -- - " WALL ZONE DIAGRAM - ELEVATION ' ' I <br /> NOTE: FOR PARAPET LOADS P1,P2,P3 AT(4)&(5), <br /> ULTIMATE(LRFD)WIND SPEED V_ _ - - - - _ _ � - - _ 110 MPH SEE WALL WIND PRESSURE SCHEDULE. <br /> I i <br /> NOMINAL{ASD)WIND SPEED V _ _ - - _ _ _ _ - - - - 85 MPH <br /> . <br /> EXPOSURECATEGORY_ _ _ - _ _ _ _ _ _ _ _ _ _ _ C I <br /> IMPORTANCE FACTOR I wind 1.00(1.15 FOR FACTORY MUTUAL COMPONENTS) � � <br /> , - - COMPONENT&CLADDING ULTIMATE WALL WIND PRESSURE (PSF) SCHEDULE I <br /> INTERNAL PRESSURE COEFFICIENT ±0.18 <br /> TRIBUTARY AREA(SF) <br /> I I <br /> ZONE � <br /> 10 20 50 100 200 500 � <br /> O4 -37.4,+37.4 -36.3,+36,3 -34,4,+34.4 •329,+32,9 -31.8,+31.8 -29.9,+29.9 <br /> O �68.6,+31.4 �3.8,+34.8 -56.9,+31 A -52,8,+28.8 -47.3,+25.8 -412,+22.4 I <br /> PARAPET ROOF PRESSURES 4' +37.4,-85.9,•37,4 +36,3,-81.6,-36.3 +34.4,•75,6,-34.4 +32.9,-70.4,-32.9 +31.8,�5,1,-31,8 +Zg.g,�0.1,•29.9 <br /> (SEE LEGEND&SECTION) O +37,4,•117.0,�8.6 +34,8,-111.2,�63.8 +31,0,•103.0,-56.9 +2s.a,-95.9,-52.8 +28.8,-90.1,-47,3 +22.4,-81.9,-012 C O M P O N E N T & C LA D D I N G W I N D L OA D � <br /> I.EGEND: <br /> +��,4,-81.9,.��,z- PARAPET ZONE DIAGRAM - SECTION <br /> ; P1,P2,P3 <br /> STRUCTURAL ENGINEER-OF-RECORD <br /> I , � � ������; CMC CARY ENGINEERING <br /> � '� P.O. BOX 2525 <br /> I '_ _ � ������ GREENVILLE,SC 29602 <br /> www.brph.com Copyright o 2017 � � PHONE: 864-609-5340 , <br /> Architects, Engineers, Constructors FAX:864-609-5344 <br /> 19020 33rd Ave'N,Suite 530 State of Washingfon <br /> Lynnwood,Washington,9d036 Ce�tificate of Autnorizatioa <br /> � Engine2ring No.3137 <br /> 425-921-3500 P,rchitecture o. <br /> CMCCE PROJECT#14-1061 � <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED �ATE �PS N i N c r oN . ACCEPTABILITY ��KED 10/09114 DESIGN CRITERIA W2548317 10/09/14 0 � <br /> 0 Issue For Construction DWD AKR 10109114 �, THIS DESIGN AND/OR RLP 10l09114 SHEET FOR � <br /> SPECIFICATION IS APPROVED r <br /> sn+i-oweN stEE� ENGINEER TITLE o <br /> BOE��� � COMPANY,INC. APPROVED BY DEPT. DATE ,AKR 10/09114 Boeing 777X CWC BUILDING REFERENCE c� <br /> N0.2szo4-000si27 CHECKED �� � <br /> I ��F , �o APPROVED B U I L D I N G T O�V V �pg Np, COMP NO. O N LY�O_ - � <br /> .� - \tiP A rover 58 S2 0 . <br /> 'TF oF AujH°� APPROVED 1STRUCTURAL MASTER EVERETT, WA DWG NO. L�O'�JO-SZ <br /> , <br />