Laserfiche WebLink
� PANEL PAINT BOOTH 3 & 4 ONLY: <br /> MISCELLANEOUS STEEL: <br /> � 1. DESIGN, FABRICATION AND ERECTION OF ALL MISCELLANEOUS STEEL SHALL BE IN � <br /> � ACCORDANCE WITH THE AISC MANUAL OF STEEL CONSTRUCTION, 14TH EDITION, UNLESS <br /> � OTHERWISE NOTED ON THE DRAWINGS. <br /> 2. MATERIALS SHALL MEET THE REQUIREMENTS OF THE FOLLOWING SPECIFICATIONS, <br /> UNLESS NOTED: <br /> a. STRUCTURAL STEEL:ASTM A992, 50ksi, MIN (C12 AND LARGER, W8 AND LARGER) <br /> � b. HOLLOW STEEL SECTIONS (HSS, aka TUBES):ASTM A500, GRADE B, 46 ksi <br /> ° c. STEEL PIPE: ASTM A53, TYPE E OR S, GRADE B <br /> d. ALL OTHER STEEL: ASTM A36, UNLESS NOTED <br /> e. BOLTS: ASTM A325 N <br /> f. WELDING: ELECTRODES AWS A5.1 E70xx � <br /> 9 <br /> 0 <br /> 3. SUBMITTALS: THE FABRICATOR SHALL SUBMIT DESIGN CALCULATIONS FOR STAIR <br /> MEMBERS, HANDRAILS, GUARDRAILS AND CONNECTIONS. THESE CALCULATIONS SHALL BE <br /> � SEALED BY A STRUCTURAL ENGINEER REGISTERED IN THE JURISDICTION WHERE THE <br /> � PROJECT IS LOCATED. THEY SHALL BE SUBMITfED AND APPROVED BY CMC CE, PRIOR TO <br /> THE SUBMITTAL OF ANY AFFECTED SHOP DRAWINGS. <br /> ; 4. STEEL STAIRS: DESIGN, FABRICATE AND INSTALL STEEL STAIRS TO WITHSTAND THE <br /> ' FOLLOWING STRUCTURAL LOADS WITHOUT EXCEEDING THE ALLOWABLE DESIGN WORKING <br /> STRESS OF THE MATERIALS INVOLVED, INCLUDING ANCHORS AND CONNECTIONS. APPLY <br /> EACH LOAD TO PRODUCE THE MAXIMUM STRESS IN EACH COMPONENT OF STEEL 5TAIRS. <br /> a. TREADS OF STEEL STAIRS: CAPABLE OF WITHSTANDING A UNIFORM LOAD OF 100 Ibf PER � <br /> SQ. FT. OR A CONCENTRATED LOAD OF 3Q0 Ibf ON AN AREA OF 4SQ INCHES LOCATED IN <br /> THE CENTER OF THE TREAD, WHICHEVER PRODUCES THE GREATER STRESS. <br /> b. PLATFORMS OF STEEL STAIRS: CAPABLE OF WITHSTANDING A UNIFORM LOAD OF 100 Ibf <br /> PER SQ. FT. <br /> c. STEEL FRAMING: CAPABLE OF WITHSTANDING STRESSES RESULTING FROM LOADS <br /> SPECIFIED ABOVE AS WELL AS STRESSES RESULTWG FROM RAILING SYSTEM LOADS. <br /> � <br /> . 5. HANDRAILS AND RAILING SYSTEM: D�SIGN, FABRICATE AND INSTALL HANDRAILS AND <br /> RAILIN� SYSTEMS TO WITHSTAND THE FOLLOWING STRUCTURAL LOADS WITHOUT <br /> EXCEEDING THE ALLOWABLE DESIGN WORKING STRESS OF THE MATERIALS tNVOLVED, <br /> INCLUDING ANCHORS AND CONNECTIONS. APPLY EACH LOAD TO PRODUCE THE MAXIMUM . <br /> STRESS IN EACH OF THE RESPECTIVE COMPONENTS OF EACH METAL FABRICATION. <br /> a. TOP RAIL OF GUARDRAIL SYSTEMS: CONCENTRATED LOAD OF 200 Ibf APPLIED AT ANY <br /> POINT AND IN ANY DIRECTION. UNIFORM LOAD OF 50 Ibf PER LINEAR FOOT APPLIED IN ANY <br /> DIRECTION ON THE TOP RAIL. CONCENTRATED AND UNIFORM LOADS ABOVE NEED NOT BE <br /> ASSUMED TO ACT SIMULTANEOUSLY. <br /> b. HANDRAILS NOT SERVING AS TOP RAILS: CONCENTRATED LOAD OF 200 Ibf APPLIED AT ANY <br /> POINT AND IN ANY DIRECTION. UNIFORM LOAD OF 50 Ibf PER LINEAR FOOT APPLIED IN ANY <br /> DIRECTION. CONCENTRATED AND UNIFORM LOADS ABOVE NEED NOT BE ASSUMED TO ACT <br /> SIMULTANEOUSLY. <br /> c. INF{LL AREA OF GUARDRAIL SYSTEMS: CAPABLE OF WITHSTANDING A HORIZONTAL <br /> CONCENTRATED LOAD OF 50 Ibf TO ONE SQ. FT.AT ANY POINT IN THE SYSTEM INCLUDING � <br /> PANELS, INTERMEDIATE RAILS, BALUSTERS OR OTHER ELEMENTS COMPOSING THE INFILL <br /> AREA. <br /> 6. GALVANIZING REPAIR PAINT: HIGH ZINC DUST CONTENT PAINT FOR RE-GALVANIZING <br /> WELDS IN GALVANIZED STEEL, WITH DRY FILM CONTAINING NOT LESS THAN 94%ZINC DUST <br /> BY WEIGHT, AND COMPLYING WITH DOD P21035 OR SSPC PAINT 20. <br /> ADHESIVE ANCHORS: <br /> 1. FOR POST-INSTALLED ADHESIVE ANCHORS INTO CONCRETE, PRODUCTS SHALL HAVE , <br /> BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH AC1355.4 AND ICC-ES <br /> AC308. PRE-APPROVED ADHESIVES INCLUDE: <br /> A. SIMPSON STRONG-TIE "SET XP" (ICC-ES ESR-2508) <br /> B. HILTI HIT-RE 500SD (ICC-ES ESR-2322) <br /> 2. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE LISTED ABOVE <br /> MAY BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER-OF-RECORD (EOR) <br /> FOR REVIEW. SUBSTITUTIONS WILL ONLY BE CONSIDERED FOR PRODUCTS <br /> HAVING A CODE REPORT RECOGNIZING THE PRODUCT FOR THE APPROPRIATE <br /> APPLICATION. SUBSTITUTION REQUESTS SHALL INCLUDE CALCULATIONS <br /> DEMONSTRATWG THE SUBSTITUTION IS THE EQUIVALENT CAPABLE OF ACHIEVING <br /> PERFORMANCE VALUES OF THE PRE-APPROVED PRODUCTS. . <br /> 3. ADHESIVE ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S <br /> INSTRUCTIONS. THE CONTRACTOR SHALL CONTACT THE MANUFACTURER FOR <br /> PRODUCT INSTALLATION TRAINING. <br /> 4. MINIMUM EMBEDMENT FOR ADHESIVE ANCHORS SHALL BE AS FOLLOWS, UNO: <br /> 1/2" DIA=41/2" 3/4" DIA= 63/4" <br /> 5/8" DIA= 55/8" 1" DIA= 9° <br /> MECHANICAL ANCHORS: . <br /> 1, FOR POST-INSTALLED MECHANICAL ANCHORS INTO CONCRETE, PRODUCTS SHALL <br /> HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH AC1355.2 AND ICC- <br /> I� ES AC193. PRE-APPROVED ANCHORS INCLUDE: <br /> i A. SIMPSON STRONG-TIE "STRONG-BOLT 2° (ICGES ESR-3037) <br /> B. HILTI KWIK-BOLT TZ(ICC-ES ESR-1917) <br /> 2. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE LISTED ABOVE <br /> MAY BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER-OF-RECORD (EOR) <br /> FOR REVIEW. SUBSTITUTIONS WILL ONLY BE CONSIDERED FOR PRODUCTS <br /> HAVING A CODE REPORT RECOGNIZING THE PRODUCT FOR THE APPROPRIATE <br /> APPLICATION. SUBSTITUTION REQUESTS SHALL INCLUDE CALCULATIONS � <br /> DEMONSTRATING THE SUBSTITUTION IS THE EQUIVALENT CAPABLE OF ACHIEVING <br /> PERFORMANCE VALUES OF THE PRE-APPROVED PRODUCTS. <br /> 3. MECHANICAL ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S <br /> � WSTRUCTIONS. THE CONTRACTOR SHALL CONTACT THE MANUFACTURER FOR PRODUCT <br /> INSTALLATION TRAINING. Qp,UL Bq�q <br /> ��p��F WASy�yyv <br /> . � <br /> DEBRIS MITIGATI N. °a'" `�� � c��`� <br /> 0 <br /> � <br /> www.brph.com Copyright o 2017 ��Gl �r 184�����- <br /> 1. CONTRACTOR SHALL COORDINATE WITH OWNER FOR DEBRIS MITIGATION AND CLEAN-UP <br /> REQUIREMENTS FOR ALL CONSTRUCTION ACTIVITIES AFFECTING AREAS WITHIN THE Architects, Engineers�at Cons tr�uctors Fss���A L ��G��� . <br /> EXISTING OPERATIONAL BUILDING. 19020 33rd Ave W,Suite 530 A L <br /> Ce�ificate of AuthorizaGon <br /> Lynnwood,Washington,98036 Architecture No.603235512 Dovid P. Balowa der <br /> 425-921-3500 Engineering No.3137 WA PE 28184� <br /> SYM REVfSION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> aF WASH, ACCEPTABILITY c�P o8 os » PHASE II - GENERAL NOTES / / <br /> 0 ISSUE FOR CONSTRUCTION CLP AHM 08�08�17 ,�P�`` N�ro THIS DESIGN AND/OR CHE K D W2548317 O 08 08 17 <br /> � � SPECIFICATION IS APPROVED AHM 08 08 17 SHEET <br /> BOE��� � BRPHARCHITECTS DPB OS 08 17 TITLE BOEING 777X CWC BUILDING 2 h <br /> ENGINEERS INC. APPROVED BY DEPT. DATE � <br /> N0.3137 CHECKED <br /> 9 � � � BUILDING 40-058 � <br /> P� o APPROVED JOB N0. COMP N0. <br /> P g <br /> /c�TF OF AU1N��\v APPROVED STRUCTURAL MASTER EVERETT, Wq DWG N0. t}O—O'rJH—S2I1 . <br />