3003 W CASINO RD 2017 BLDG 40-58 Plans 2022-11-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2017 BLDG 40-58 Plans 2022-11-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 10:28:04 AM
Creation date
6/17/2019 10:00:42 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
B1708-033
Year
2017
Notes
PAINT BOOTHS 3 AND 4
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
247
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PANEL PAINT BOOTH 3 & 4 ONLY: <br /> SOILS CONSTRUCTION (IBC 1705.6): MASTIC AND INTUMESCENT FIRE RESISTANT COATINGS (IBC 1705.14): � <br /> ITEM FREQUENCY OF INSPECTION INSTRUCTIONS ITEM FREQUENCY OF INSPECTION INSTRUCTIONS <br /> VERIFY SUBGRADE fS ADEQUATE TO CONTINUOUS � PERIODIC ❑ PRIOR TO PLACEMENT OF CONCRETE. SURFACE PREPARATION CONTINUOUS ❑ PERIODIC � PRIOR TO APPLICATION CONFIRM THAT SURFACE <br /> ACHIEVE DESIGN BEARING CAPACITY TEMPERATURE AND SUBSTRATE ARE <br /> ACCEPTABLE AND THAT A COMPATIBLE PRIMER IS <br /> USED IN ACCORDANCE WITH AWCI 12-B <br /> VERIFY EXCAVATIONS EXTEND TO CONTINUOUS ❑ PERIODIC � PRIOR TO PLACEMENT OF COMPACTED FILL <br /> PROPER DEPTH AND MATERIAL OR CONCRETE. <br /> VERIFY THAT SUBGRADE HAS BEEN CONTINUOUS � PERIODIC ❑ PRIOR TO PLACEMENT OF COMPACTED FILL. THICKNESS CONTINUOUS ❑ PERIODIC � RECORD THICKNESS OF PRIMER OR OTHER ' <br /> EXISTING COATING ON SUBSTRATE PRIOR TO <br /> APPROPRIATELY PREPARED PRIOR TO APPLICATION OF COATING. FINAL THtCKNESS OF <br /> PLACING COMPACTED FILL COATING MUST BE VERIFIED IN MULTIPLE <br /> LOCATIONS PRIOR TO APPLYING TOP COAT PER <br /> PERFORM CLASSIFICATION AND CONTINUOUS � PERIODIG ❑ ALL MATERIALS SHALL BE CHECKED AT AWCI 12-B. <br /> TESTING OF COMPACTED FILL EACH LIFT FOR PROPER CLASSIFICATIONS <br /> MATERIALS AND GRADATIONS NOT LESS THAN ONCE ARCHITEItTURt1L COMPONENTS (I BC � 705. 12 & 1705. � 2). <br /> FOR EACH 10,OOOFT 2 OF SURFACE AREA. <br /> ITEM FREQUENCY OF INSPECTION INSTRUCTIONS <br /> VERIFY PROPER MATERIALS, CONTINUOUS � PERIODIC ❑ � <br /> DENSITIES AND LIFT THICKNESSES ERECTION AND FASTENING OF CONTINUOUS ❑ PERIODIC � VERIFY APPROPRIATE MATERIALS, FASTENERS AND <br /> DURING PLACEMENT AND EXTERIOR CLADDING OR INTERIOR ATTACHMENT AT COMMENCEMENT OF WORK AND <br /> COMPACTION AND EXTERIOR VENEERS AT COMPLETION. PERFORMED BY CODE INSPECTION <br /> FIRM. (NOT REQUIRED IF <30 FEET OR LESS THAN <br /> � 5PSF). <br /> ERECTION AND FASTENING OF CONTINUOUS ❑ PERIODIC � VERIFY APPROPRIATE MATERIALS, FASTENERS <br /> INTERIOR AND EXTERIOR AND ATTACHMENT AT COMMENCEMENT OF WORK <br /> NONBEARING WALLS AND AT COMPLETION. PERFORMED BY CODE <br /> INSPECTION FIRM. (NOT REQUIRED IF <30 FEET , <br /> OR FOR INTERIOR WALLS < 15PSF). <br /> STORAGE RACKS CONTINUOUS ❑ PERIODIC � VERIFY THAT ANCHORA�E COMPLIES WITH <br /> APPROVED CONSTRUCTION DOCUMENTS. <br /> INSPECTION OF POST-INSTALLED ANCHORS SHALL <br /> COMPLY WITH APPROVED ICGES REPORT. <br /> PERFORMED BY CODE INSPECTION FIRM. <br /> MECHANICAL & ELECTRICAL COMPONENTS (IBC 1705.12.6 & 1705.12.8): <br /> ITEM FREQUENCY OF INSPECTION INSTRUCTIONS <br /> ANCHORAGE OF EMERGENCY OR CONTINUOUS ❑ PERIODIC � VERIFY THAT ANCHORAGE COMPLIES WITH <br /> � STANDBY POWER SYSTEMS APPROVED CONSTRUCTION DOCUMENTS. <br /> PERFORMED BY CODE INSPECT/ON FIRM. <br /> INSTALLATION OF PIPING SYSTEMS CONTINUOUS � PERIODIC ❑ VERIFY THAT INSTALLATION AND RESISTANT <br /> CARRYING FLAMMABLE, COMPLY WITH APPROVED CONSTRUCTION � <br /> COMBUSTIBLE OR HIGHLY TOXIC DOCUMENTS. PERFORMED BY CODE INSPECTION <br /> MATERIALS FIRM. <br /> INSTALLATION OF HVAC DUCTW�RK CONTINUOUS ❑ PERIODIC ❑ VERIFY THAT INSTALLATION AND RESISTANT <br /> CONTAINING HAZARDOUS COMPLY WITH APPROVED CONSTRUCTION <br /> MATERIALS DOCUMENTS. PERFORMED BY COpE lNSPECTION <br /> FIRM, <br /> INSTALLATION OF VIBRATION CONTINUOUS � PERIODIC ❑ VERIFY THAT INSTALLATION COMPLIES WITH � <br /> ISOLATION SYSTEMS HAVING A APPROVED CONSTRUCTION DOCUMENTS AND <br /> CLEARANCE OF < 1/4". MANUFACTURERS RECOMMENDATIONS, <br /> PERFORMED BY CODE INSPECTION FIRM. <br /> DESIGNATED SEISMIC SYSTEMS CONTINUOUS � PERIODIC ❑ CONFIRM THAT MANUFACTURERS CERTIFICATION <br /> � OF COMPLIANCE CONFORMS TO THE <br /> REQUIREMENTS OF SECTION 13.2 OF ASCE 7-10. <br /> VERIFY THAT THE LABEL, ANCHORAGE OR <br /> MOUNTING CONFORMS TO THE MANUFACTURER'S <br /> CERTIFICATION OF COMPLIANCE. PERFORMED BY • <br /> CODE 1NSPECTION FIRM. <br /> SPECIAL CASES (IBC 1705. 1 . 1 )-MATERIAL ALTERNATIVES OR UNUSUAL <br /> DESIGN APPLICATIONS: <br /> ITEM FREQUENCY OF INSPECTION INSTRUCTIONS <br /> y <br /> MATERIALS AND INSTALLATION CONTINUOUS � PERIODIC ❑ PER DESIGN PROFESSIONAL IN RESPONSIBLE , <br /> CHARGE OR REPORT FROM AN ACCEPTED <br /> ACCREDITATION AGENCY (I.E. ICC-ES). <br /> Q�,uL Bq�� <br /> �\p��F WASy�yyv <br /> � � c'�4� <br /> � DAVI � W O � . <br /> t.n <br /> L� <br /> www.brph.com Copyright 0 2017 � <br /> �li 184 �� �- <br /> Architects, Engineers, Constructors '�Fss� RA L ��G��`��` <br /> 19020 33rd Ave W,Suite 530 State of Washington �NA L �� <br /> Ce�ificate of Authorization <br /> Lynnwood,Washington,98036 Atchitecture No,603235512 Dovid P. Balawo der � <br /> 425-921-3500 Engineering No.3137 WA PE 28184� <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTI7LE CURRENT REVISION SYMBOL DATE <br /> aF WASH, ACCEPTABILITY c�P o8 os ,� PHASE II - STATEMENT OF SPECIAL INSPECTIONS / / <br /> 0 ISSUE FOR CONSTRUCTION CLP AHM 08/08/17 ,�P�� N�r THIS DESIGN AND/OR ECK D W2548317 08 08 17 <br /> � �� SPECIFICATION IS APPROVED AHM 08 08 17 SHEEf <br /> BOE,��� BENGWEERS NCS APPROVED BY DEPT. DATE DPB 08 08 17 TITLE BOEING 777X CWC BUILDING <br /> N0.3137 CHECKED S 2( <br /> � BUILDING 40 058 <br /> JOB N0. COMP N0. <br /> �� o APPROV D � <br /> � �T� P�� O_ <br /> i °qTF oF A�s���`ti APPROVED STRUCTURAL MASTER EVERETT, Wq °wc No. 40-058—S21 � <br />