Laserfiche WebLink
�.�o �.�� �.�o �.�� �.�o �.�� � 4.8 L E G E N D <br /> W12x79 Q <br /> 25'-0" 25'-0" 25'-0" 25'-0" 30'-0" 30'-0" CANT, 502-1 31'-0" <br /> SFRS INDICATES SEISMIC FORCE RESISTING SYSTEM.ALL SFRS WELDS ARE <br /> � ._ .� _ � � � � _. .� .._.. � _______ _ � � ._ J.7� TO BE MADE WITH FILLER ML�ALS MEETWG THE REQUIREMENTS OF ' <br /> G HSS4x4 ,Y ( HSS4x4 POST UP.SEE STRUCTURAL AWS D1.8,CLAUSE 6.3 <br /> I ! ( � I � 502-1 POST BELOW °' STEEL DWGS FOR DETAILS � <br /> 4 � 5'-10" � 7'-7" BRACED FRAME.SEE <br /> � <br /> - � : BUILDWG STRUCTURAL <br /> �� � o W12x79 �;, 15K STEEL DWGS FOR DETAtLS <br /> I N Y <br /> I A <br /> � <br /> � I I I I ! � I r I <br /> 1 , „ <br /> 502-1 <br /> — GENERAL NOTES <br /> - 3-0 <br /> .- <br /> � �� <br /> , <br /> 4 EQ.SP. <br /> I � 6-4 � ) <br /> — —�,,--- °��..-° °O � (_)INDICATES NUMBER OF UNIFORML.Y SPACED 3/4°DIA.x 4"LONG <br /> � d. � <br /> � � N , N HEADED SHEAR STUDS <br /> � . _ <br /> �-I 5 5 �, <br /> ( � I I I __ � � 7 F - 2° 20GA COMPOSITE METAL DECK W/3°CONCRETE FILL REINFORCED <br /> — � � <br /> — r� <br /> � <br /> 2 <br /> � �. X � , <br /> Y 502-1 <br /> � ,� � _ �� <br /> �, 10 E . - <br /> Y WITH#4 12 O.C.E.W. C NT D TOTAL SLAB THICKNESS 5 . <br /> o @ � <br /> I <br /> � <br /> r <br /> 6 <br /> � ,� <br /> N _ <br /> 8x10 _ _ <br /> E 1 - D <br /> BF-12 20K � W12x79(15) � SIM. T/ST EL ELEVATION 1 1 1 ,SEE ETAIL 11S50218 <br /> � <br /> Y 20K 1 K 1 , <br /> � <br /> O.H. * <br /> — INDICATES TO SEE BUILDING STRUCTURAL STEEL DWG S FOR SIZE. <br /> � �) <br /> 2 Y Y BF-11 Y Y <br /> H <br /> 3. <br /> I cD � o 0 0 0 <br /> � ( � � <br /> � � SI P � r- .- 502-1 <br /> � <br /> • ) <br /> � r� � � � W8x10 _ <br /> , <br /> PRE ENGINEERED METAL STAIR BY DELEGATED ENGINEER. <br /> I <br /> cv 4 <br /> X Z � TYP. � <br /> ( 502-1 W8x10 2_g 5, FOR COLUMN SIZES SEE SHEET S502-1. <br /> 0 o u- <br /> � G+ W 10 W8x10 0 0 � o m , ,� <br /> — o� ao 00 00 <br /> � 5�2-� ,� m �N �' � � � 6� 1-1/2",20GA,TYPE B METAL ROOF DECK. <br /> I � , � � 0 N ( - <br /> � Y M � <br /> � — _. � � � _ � r ._ _ .� � � � � ` " 20K � • 40 .ro __.`__._Q —. Y e Y _ <br /> � � .d- o W12x79 0 — �- � � K � 4"HOUSEKEEPING PAD.SEE DETAIL 2IS502-18. <br /> y N (15) � .� Q — <br /> ao ' ? / 1 I ' BF-10 I g, (_K)INDICATES ULTIMATE FACTORED REACTION IN KIPS. <br /> m I � 4'-62' O° 2 CONNECTIONS NOT DETAILED ARE TO BE DESIGNED FOR THE • <br /> 1 I � � � � r. Q � POST-UP W$x10, � INDICATED REACTIONS BY A LICENSED DELEGATED ENGINEER, <br /> � I N � � � 502-2 0 � W10x68 TYP. ��N <br /> �. — — I � � 1 / W10x68� � H � 9, COORDINATE ALL SLAB PENETRATIONS WITH MIE/P FOR SIZE AND <br /> TBF-13 I � 502-1 `�' FINAL LOCATIONS. <br /> T/SLAB C6x8.2 — , _ _ — SIM. 10. ALL EXTERIOR EXPOSED STEEL TO BE HOT DIPPED GALVANIZED. <br /> ( ( � � I I EL. 111'-6" Y 4'-6" � POST-UP � <br /> ' � � N M W10x68 4 11 PROVIDE 1!2°EXPANSION JOINT MATERIAL AROUND PORTION OF <br /> ( P.(6 PLC'S) 1 I TBF-7(15} � Y x � M 3 502-2 �, BRACE AND GUSSET PL EMBEDDED IN CONCRETE.TYPICAL ALL <br /> � � 3 Y � � I '� 502-2 M BRACES. <br /> � � � � � ��x$'z 12 HSS6x6x114 ELEVATOR DOOR FRAMING SEE SECTION AIS502-18 <br /> mI m I , I I � 502-1 �� YI � FORHSS10x4 i 16 � <br />,:� � 25K 6x$,2 � \/ X `�'� CONNECTION SEE FOR CONNECTION DETAILS. <br />'� � -- C/S502-5c <br /> 12x79(15) � 30K � 13 HSS6xZx114 ELEVATOR DOOR HEADER FRAMING,SEE SECTION <br /> M �� � ��? E/S502-18 FOR HEADER ELEVAT10N AND CONNECTION DETAILS. <br /> I ( i I I � 6 C6x8,2 `� M POUR STOP BY <br /> C6x8. � DECK SUPPLIER I <br /> � � _ TBF-13 � TYP.AT BF I 3'-2° <br /> GUSSET PL <br /> 2'-10" ��,, � <br /> ' _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _._ .__ .__. _ ._ . _ .._._ _ _ 5o2-z _ � _ � - - - — - - K.25 <br /> 3 � I I I I � � � 2 I <br /> � <br /> W12x19(8) I 502-1 -�P.AT BUILDING <br /> �P � COL'S(3 PLC'S) <br />� m � (6)#6 @ 3"O.C.ADD'L , <br /> ( � � I � � � I A `� (LAP 3'-0"),SEE AIS502-15 � <br /> � <br /> 5°2_' � CONSTRUCTION NOTES <br /> I � H <br /> �/ 502-1 TYP AT OPENINGS <br /> BF-12 <br /> � I — --I-- I I � 1 I25K M 25K v, � `-'' <br /> � Y � W12x79(15) X I `'' <br /> . N ol �`- • N . <br /> �� N �( <br /> � � �. � � � $�, � o A <br /> � � BF-12 � I � � � � � � � � � 25K �� �_ 1�� 502-1 I <br />� � _ v — � ' _ � � � 25K 2 4-2 . <br /> , <br /> I � � � � � � W � � BF-2 M W12x79(15) � I <br /> � <br /> � <br /> m <br /> 11 <br /> I � I I ! I i I nP. �I I <br /> o _ _ _ _ _ _ � _ �. _ � __ I _ _ _ i _ _ ._._ _ I _ _.__ _ _._. � _ _ ' _ _ _ � — Y I ' " _ _ _ K.50 <br /> � I � � 17-6 <br /> �IW12x19(8) � 9'-1" 7'-11" 13'-102" <br /> � , , � � � � a � 2EQ.5P. 2EQ.SP. =�N REFERENCE DRAWINGS <br /> I I l I I I � � � <br /> ( °O ( ��' B SIM. 502-1 6" <br /> � � TYP.{8 PLCS) I � ' 502-1 O,H. 1'-11" <br />� l � I I I I 1 1 2�_5�� � I 4 � <br /> X � <br /> � <br /> � � � ` I I 502-1 ��2�� � M <br /> � 10x 8(10) BF-6� �, <br /> � -3 _ � � — — — -- — -- — _._. � _.._ — -- _ � � " W12x79(15) 25K 10 _ 10K � Y Y � b�, <br /> II � 1 I I I � BF-2 - � � <br /> 0 5K "' <br /> � M � I � <br /> 2 � C6x8.2 � � N � �o WT X • <br /> � i i � � � � � � N X � -- <br /> �� � o csX � � � � � N -�TI�ITIT, F � = - <br /> � � � � <br /> IN � <br /> � �1 � �I25K � � � 25K o � Y � � I 502-1 � � � <br /> <- Y � 12x14 � W10X4 � OK � � <br /> � I --� I — — e _i�_.__._ .._ � � � � _ _ .� � ._ ___}__�._ � ._._ �. �}-- Y W12x79(15) °° 10 Y 10K �' <br />� I I I I i I I I BF-2 M ( o .A w o,�' � �N . <br /> — � � oo`v 50 - tl' � `L � <br /> m c� <br /> I i _ _ _ _ _ _ _ _ _ _._ _ _ . _ _ � _ _ _ _ 12 _ , � � � K.�75 <br /> � � I a � 1 C I I I T/SLAB �, ti ��N � � �� O° o <br /> � � EL.111'-6" ( � � , � � 502-5cSIM.O.H. ��� � � - <br /> I I I i I I 4 I � � 2-� X o� ��' � �� N w 4�.�2�� o r! <br /> � 1'-6" N �" H S502-5c { <br /> � � � � <br /> � � W12x19 � � Y 5�-1 �..� Y� <br /> I � I I i I � I I I H �8� � � \ <br /> o � <br /> I I i � � f TyP. 502-1 C6x8.2 W Ox68(10 <br /> � I M _ � �� BF-6 � <br /> 4 PLACES N � <br /> � o � LL C6x8.2 }=� 8-4 <br /> I I m� <br /> , „ , <br />� i � � i � � � � � � 7-7 1 5B� � . <br /> � 0° ( � � ( � ( � I Y � A 502-1 SIM. <br /> � BF-12 + ` � � ` _ � � _ � � � � � _ BF-2� � M 12x79 15 502-1 O.H. <br /> l TYP. Y 25K 25K <br /> o � I � <br /> - I I I I A � � � o N <br /> 502-2 8" N o - <br /> 1 � � I � <br /> TYP, <br /> 502_2 �I Y :— QPU WBq�'��L FOR REFERENCE ONLY <br /> _ �') �*) �*) �*) (*) 15K � W21x44 � � _ � � � V -������ ,Sy�'y�,9"O� <br /> DA � NA � <br /> � 1„ `,�' <br />� �� r='� 16'-5" www.brph.com Co ri ht o � � <br /> c� B (2j EQ.SP. � 1�� PY g 2017 ��Gr 184 ��� ��- � , > > > <br /> P2P PANEL PAINT - HOUSE MECHANICAL LEVEL FRAMING PLAN - BQOTH #1 2-�2 Architects, Engineers, Constructors �ss RAL �� ��`� 0 4 8 16 24 Q <br /> 502-1 ') A' 19020 33rd Ave W,Suite 530 State of Washington �ONA� �,��' N <br /> SCALE:1/8" = 1'-0° - S502-2 y 9 Certificate of Authorization .- <br /> �V L nnwood,Washin ton,98036 » > » <br /> 425-921-3500 Architecture No.603235512 David P. Balawajder 1 /8 = 1 -0 0 <br /> Engineering No.3137 WA PE 28184 00 <br /> SYM REVISION BY APPROVED DATE SYM REVISIpN BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DAT� o <br /> oF yyqSH� ACCEPTABILITY c�P ,z 20 ,s ENLARGED TOOLING PLAN W2548317 16 12/20/16 � <br /> 10 REVISION — RELEASE 47 (PANEL PAINT� CLP AHM 07,12�16 15 REVISION — RELEASE 56 (PANEL PAINT� CLP AHM 11�15�16 y,�P�� "�roy THIS DESIGN AND/OR AHM K 12 20 16 r i <br /> SPECIFICATION IS APPROVED SHEET <br /> 11 REVISION — RELEASE 51 (PANEL PAINT) CLP AHM 09/06/16 16 REVISION — RELEASE 58 (PANEL PAINT) CLP AHM 12/20/16 �0�,��� BRPHARCHITECTS TiT�e BOEING 777X CWC BUILDING � <br /> EN�INEERS INC. APPROVED BY DEPT. DATE DPB 12 20 16 S 5 0 2 2 <br /> 12 REVISION — RELEASE 52 (PANEL PAINT) CLP AHM 09/20/16 7 REVISION — RELEASE 44 (PANE� PAINT) CLP AHM 06/02/16 � N0.3137 CHECKED � <br />� 13 REVISION — RELEASE 53 (PANEL PAINT) CLP AHM 10/04/16 8 REVISION — RELEASE 45 (PANEL PAINT) CLP AHM 06/14/16 <br /> ��F �o APPROVED B U I L D I N G T O�O V H JOB N0. COMP N0. Y <br /> � <br /> 14 REVIS40N — RELEASE 55 (PANEL PAINT� CLP AHM 11�01�16 9 REVISION — RELEASE 46 (PANEL PAINT� CLP AHM 06�28�16 c9TF aF Au1N°�`�tiP APPROVED STRUCTURAL MASTER EVERETT, �ll�/� °wc No. 40-058-S502-2 <br />