Laserfiche WebLink
i , <br /> ; : <br /> � <br /> �PACU PACU <br /> 4 40-58 INTERIOR � —D 40-58 EXTERIOR <br /> HEATING COILS, TYP. SUPPLY FAN, TYP, <br /> DP DP A <br /> VOLUME DAMPER (TYP) T <br /> DP DP <br /> �— OSA � <br /> DP D <br /> FS � � � AIR FILTER(2-STAGE) <br /> i 1 <br /> FREEZE ( � M552-1,9 HHWR <br /> STAT � DISCHARGE ABOVE <br /> ROOF LEVEL. 3000 <br /> FPM � <br /> AT EXIT. <br /> HHWS � <br /> CONTROL VALVES <br /> CEILING MOUNTED <br /> AIR OUTLETS, 1440 CFM TYP, <br /> T <br /> AIR MONITORING <br /> TO AUTOMATION STORAGE DIFFERENTIAL <br /> PRESSURE <br /> DP SENSORS, TYP. <br /> 777 W I N G PAN E L T EF EF <br /> 49 52 <br /> H <br /> TO FACTORY FLOOR DP DP <br /> DP <br /> DP DP <br /> P2P - PANEL PAINT 2 T <br /> ABOVE GRADE <br /> FLOOR MOUNTED DIFFERENTIAL PRESSURE gELOW GRADE EXHAUST FAN, TYP, <br /> EXHAUST GRATE, TYP, SENSOR, TYP, <br /> DP <br /> F-1 <br /> FILTER BANK, TYP. <br /> PROCESS FLOIN DIAGRAM - PACU-4, � <br /> EF-52 � <br /> NTS M1ca M1ca <br /> F-4 <br /> F-1 pp <br /> PAINT BOOTH OPERATIONAL MODES <br /> r MODE: MANUAL PAINT AUTOMATED PAINT CURE (BMS 10-20) CURE (BMS 10-103) PREP ACCELERATED CURE (BMS 5-92) MAINTENANCE MODE DP <br /> ; TEMPERATURE FLOW RATE TEMPERATURE FLOW RATE TEMPERATURE FLOW RATE TEMPERATURE FLOW RATE TEMPERATURE FLOW RATE TEMPERATURE FLOW RATE TEMPERATURE FLOW RATE <br /> � EQUIPMENT TAG POSITION SETTING POSITION SETTING POSITION SETTING POSITION SETTING POSITION SETTING POSITION SETTING POSITION SETTING <br /> ! DESCRIPTION NAME DIFFERENTIAL PRESSURE SENSORS MEASURING PLENUM <br /> � °F CFM °F SCFM °F SCFM °F SCFM °F SCFM °F SCFM °F SCFM LEVEL FILTER PRESSURE DROP ARE PHYSICALLY LOCATED <br /> ; <br /> ' AIR HANDLING PACU-1,4 ON 70 82,000 ON 70 49,200 ON 150 [1] 41,000 ON 150 [2] 41,000 ON 70 49,200 ON 150 [3] 41,000 ON 70 25,000 AND PA NT B00 O 2 ADJACENT�TO AU�TOMA�T ONOCONTROL <br /> � UNIT <br /> PANEL FOR RESPECTIVE BOOTH, TYP. <br /> j EXHAUST FAN EF-49,52 ON NA 90,200 ON NA 54,120 ON NA 45,100 ON NA 45,100 ON NA 54,120 ON NA 45,100 ON NA 27,500 <br /> , _ <br /> � BOOTH DOORS - OPEN NA NA LOCKED NA NA LOCKED NA NA LOCKED NA NA OPEN NA NA LOCKED NA NA OPEN NA NA <br /> i <br /> 1 DOORS � <br /> � DOGHOUSE TO - OPEN NA NA OPEN NA NA LOCKED NA NA LOCKED NA NA OPEN NA NA LOCKED NA NA OPEN NA NA � <br /> i <br /> i HALLWAY <br /> � DOORS AT <br /> 1 - LOCKED NA NA LOCKED NA NA LOCKED NA NA LOCKED NA NA LOCKED NA NA LOCKED NA NA OPEN NA NA <br /> � PLENUM LEVEL <br /> � [1] MAXIMUM ALLOWED TIME TO TEMPERATURE IS 10 MINUTES. <br /> + [2] MAXIMUM ALLOWED TIME TO TEMPERATURE IS 10 MINUTES. 900 SW 16th Street Suite 307 FSi consulting engineers <br /> ; [3] MAXIMUM ALLOWED TIME TO TEMPERATURE IS 10 MINUTES. Renton, Washington 98057 Solutions & Service <br /> � <br /> � � <br /> n. <br /> � SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED �aTE ACCEPTABILITY °�wrv DATE SUBTITI.E CURRENT REVISION SYMBOL DATE N <br /> ; o IssueForConstruction FSi BSC 03101l16 W• ( THISDESIGNAND/OR CHECKED Q91O6��6 PROCESS FLOW DIAGRAM - PACU-4, EF-52 W2548317 • <br /> � 9 4 09/06/16 0 <br /> F. �Y RED 09I06/16 SHEET <br /> 02-�l��,�"�,',�� SPECIFICATION IS APPROVED ENGINEER T�TLE � <br /> � 1 Revision-Release 40 FSi BSC 04/05/16 �'► � �, o <br /> 2 Revision-Release 47 FSI B$C 07/12116 �OE,H� z APPROVED BY DEPT. DATE B$C 09/06/16 Boeing 777X CWC BUILDING <br /> �� _ M 1 ca � <br /> CHECKED N <br /> .0 4eaea � <br /> . 90,r I �� � � � � <br /> . � <br /> r BUILDING 40 58 <br /> 3 Revison-Release 50 FSi BSC 08123/16 �sS'o"�� E"G� RED ovE� JOB NO. COMP N0. � <br /> 40-58-M1ca Q <br /> 4 Revison-Release 51 FSi BSC 09106/16 APPROVED DWG NO. <br /> 09/06/16 MECHANICAL MASTER EVERETT, WA 40-58-M1ca <br />