My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8810 AIRPORT RD SWIFT STATION 2020-03-06
>
Address Records
>
AIRPORT RD
>
8810
>
SWIFT STATION
>
8810 AIRPORT RD SWIFT STATION 2020-03-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2020 7:25:05 AM
Creation date
6/18/2019 8:18:06 AM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
8810
Tenant Name
SWIFT STATION
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
meat <br /> XREF LIST PANEL LOCATION: INSIDE CABINET ENCLOSURE 120/240* VOLT, 1 PHASE, 3 WIRE. <br /> Ltucole: 1 - ABBREVIATIONS: GENERAL NOTES <br /> A SERVING: STATION SHELTER 10,000 AIC, 70 AMP with BREAKER <br /> Resolved MAIN OFCI:OWNER FURNISHED CONTRACTOR INSTALLED 1. PROVIDE 2"C FROM IT EQUIPMENT BOARD UNDERGROUND TO <br /> TTLBLK TELECOMMUNICATION SERVICE CONNECTION POINT.SEE CIVIL <br /> woeeeol CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT DRAWINGS C4 SERIES SHEETS FOR LOCATION AND ROUTE. <br /> TEL A264 04 001 RFCS:REGIONAL FARE COLLECTION SYSTEM <br /> 1 LIGHTING-ICONIC MARKER L 0.052 20/1 A 20/1 0.050 D ORCA SCANNERS 2 <br /> 3 LIGHTING-PLATFORM L 0.141 20/1 B 20/1 0.150 D RTPI DISPLAY 4 APTS:ADVANCED PUBLIC TRANSPORTATION SYSTEM 2. BRANCH CIRCUIT WIRING FROM PANEL A TO EQUIPMENT AND <br /> LIGHTING SHALL BE#12 COPPER INSTALLED IN CONDUIT.SEE <br /> 5 LIGHTING-INFORMATION PANEL L 0.058 20/1 A 20/1 0.820 D IT EQUIPMENT&IT POWER STRIP 6 PANEL SCHEDULE FOR CIRCUIT REQUIRMENTS. <br /> 7 LIGHTING-POST LAMP L 0.030 20/1 B 20/1 0.250 D FUTURE CCTV POWER 8 RTPI:REAL-TIME PASSENGER INFORMATION SIGN <br /> 9 TICKET VENDING MACHINE LEFT D 0.450 20/1 A 20/1 0.125 D PHOTO EYE&TIME CLOCK 10 GFCI:GROUND FAULT CIRCUIT INTERRUPT 3. TERMINATE CONDUITS AT UTILITY POINT TO COMPLY WITH z <br /> 11 TICKET VENDING MACHINE RIGHT D 0.450 20/1 B 20/1 0.180 D GFCI RECEPTACLE 12 - UTILITY DESIGN STANDARDS. w <br /> PHASE LOAD PHASE A= 1.55 KVA, PHASE B= 1.20 KVA. 4. CONTROL CIRCUITS 1&3 BY LIGHTING CONTACTOR. D- <br /> LOAD TYPE 5. CONNECT LIGHTING CONTACTOR TO OPERATE BY PHOTO gL< <br /> L R M H WH D A K LM TOTAL LOADS ELECTRIC CONTROL,CONNECTED IN SERIES WITH TIME SWITCH, fl- <br /> CONN. <br /> CONN.LOAD .281 2.48 2.76 KVA 13.25 AMP CONTACT#1.PARALLEL WITH KEY OPERATED OVERRIDE <br /> SWITCH,MOUNTED UNDER INFO PANEL. <br /> COMPUTED LOAD .351 2.48 2.83 KVA 13.58 AMP IS <br /> 6. CONNECT CIRCUIT 7 TO OPERATE BY TIME SWITCH CONTACT <br /> ❑ISOLATED GROUND BUS ❑FEED THRU LUGS ❑MAIN BKR SHUNT TRIP ❑PANEL SKIRTS V SURFACE <br /> #2.(CONTACTS 3&4 SPARE). <br /> d <br /> 0 RAINTIGHT NEMA-3R ENCLOSURE ❑DOUBLE LUGS VSERVICE ENTRANCE LABEL 0 INTEGRAL TVSS III FLUSH 7. PROVIDE NOISE FILTER AND INSTALL TO THE COIL OF EACH z <br /> REMARKS: DEFINITE PURPOSE CONTACTOR(2 PER TIME SWITCH). i g.CAK1 <br /> G p4 4 <br /> 8. FURNISH AND INSTALL TRANSFORMERS AS SHOWN TO CONVERT - « <br /> ,, <br /> 120/240V POWER TO 12V AND 24V RESPECTIVELY TO STATION ID ®" t c <br /> ,`., <br /> PANEL LAMPS AND INFORMATION PANEL LIGHTING. !` <br /> * THE SERVICE CONNECTION(EXCEPTION)IS A 120/208(4 WIRE)AT THE FOLLOWING LOCATIONS: �y�� <br /> STATION taNAL�'l <br /> 3026 WB 132ND ST SE/16TH AVE SE sAlirs <br /> PC PHOTOELECTRIC TIME SWITCH <br /> Z <br /> 3045 EB 132ND ST SE/16TH AVE SE <br /> CONTROL (ET904715 CR) CIRCUIT TO INFORMATION <br /> NOISE FILTER(X2) PANEL LIGHTING 0 <br /> (INTERMATIC ET-NF) TS <br /> LIGHTING FIXTURE SCHEDULE** J 24V U <br /> 4-POLE,20A CIRCUIT TO STATION <br /> IDENTIFIER PANEL <br /> 1 LIGHTING CONTACTOR 1 2V LAMPS D <br /> O <br /> UTILITY <br /> ITEM DESCRIPTION LAMPS VA MOUNTING REMARKS TRANSFORMER METER PAA <br /> NELLC CIRCUITS TO LIGHT FIXTURES CC <br /> K KEY OPERATED OVERRIDE SWITCH.ATTACH TO VJ <br /> $LOAD CENTER ENCLOSURE EXTERIOR. Z <br /> 3 LED LIGHT BAR LED 100 INSIDE ICONIC MARKER 24V >CIRCUITS TO EQUIPMENT AND RECEPTACLES 0 <br /> N <br /> • 6 POST LAMP LED 15 SURFACE 2TOTAL <br /> ROUTE UNDERGROUND TO UTILITY CONNECTION #8 BARE CU. 5/8"X8'GROUND RODS METER GROUNDED TO Z <br /> z POINT.SEE CIVIL DRAWINGS 4 SERIES SHEETS <br /> 8 STATION IDENTIFIER LAMPS INCAND 2.5 SURFACE 6 TOTAL 12V <FOR LOCATION AND ROUTING STRUCTURE. o O <br /> / <br /> 4'LED ENCLOSED STATION <br /> ▪ 9 LAMPS LED 47 SURFACE 3 TOTAL p p <br /> INSIDE INFORMATION (3)#6,3"C _ — Q <br /> 16 INFORMATION PANEL LIGHTS LED 14.4 4 TOTAL 24V PANEL GROUNDED TO <br /> PANEL STRUCTURE. <br /> .4 **SEE SPECIFICATIONS FOR DETAILED INFORMATION(OWNER FURNISHED) (1)#10 INSULATED GROUND WIRE TO . VJ <br /> NETWORK INTERFACE DEVICE 51 <br /> (NID)ON I <br /> QTY OWNER FURNISHED CONTRACTOR EQUIPMENT MOUNTING PANEL <br /> W <br /> EQUIPMENT (PER POWER COMM CONTRACTOR FURNISHED& NOTES O Z <br /> STATION) INSTALLED INSTALLED*** J <br /> N TICKET VENDING MACHINE(TVM) 2 X X CONTRACTOR TO CONNECT POWER.VENDOR WILL DO ft/ <br /> COMMISSIONING. PLATFORM EQUIPMENT & COMMUNICATION PLAN (TYPICAL) +.0Z <br /> . z <br /> STAND ALONE FAR TRANSACTION PROCESSOR 2 X X X CONTRACTOR TO CONNECT POWER AND COMM.VENDOR WILL DO 0.7.5. > W Q <br /> (SAFTP)OR CARD READER/ORCA SCANNER COMMISSIONING. <br /> o REAL TIME PASSENGER INFORMATION(RTPI) PLAN NOTES v_ W d <br /> SIGNS(DOUBLE MOUNTED) 2 X X X <br /> 0 1.IN SERVICE(4:45AM TO 12:45AM) _ <br /> CC <br /> c' 0 Q <br /> ?i ICONIC MARKER LIGHTING 1 X X TIMESWITCH-OFF 1 HOUR AFTER SUNRISE AND ON 1 E V o <br /> 0 HOUR BEFORE SUNSET <br /> zo POWER METER 1 X XIY <br /> 7° POST LAMP 2 X X 2.NO SERVICE(12:45AM TO 4:45AM) E H <br /> N TIME SWITCH-ONLY EVERY OTHER STATION LAMP(2nd ck <br /> U <br /> LLI <br /> AND 4th FROM ARRIVAL COLUMN)ON <br /> '" STATION IDENTIFIER PANEL LAMP 6 X X {J CA., —1 <br /> a• STATION LAMP 4 X X 3.PHOTOCELL INSTALLED FOR FUTURE USE �/J w <br /> BUT ELECTRICALLY DISCONNECTED AT THIS TIME O <br /> > LOAD CENTER 1 X X <br /> INFORMATION PANEL 2 x x Snohomish County Planning&Development Services <br /> APPROVED FOR CONSTRUCTION <br /> • ROUTER 1 X X X CRADLEPOINT COR 1BR650 By: <br /> E SWITCH 1 X X X BLACKBOX LBH101A-H RIW Permit No. Il na GtobalPartner <br /> `O4. CAT5e DISCONNECT PANEL 1 X X BLACKBOX JPM083A-R3 11241 Suite 2 Road NE <br /> Date: Suite zoo <br /> Redmond.Washington M052 <br /> SURGE PROTECTOR(8 RECEPTICLE) 1 X X Phone:(425)822-4446 <br /> FAX:(425)827-9577 <br /> N 12V TRANSFORMER 1 X X INSTALL ONE T100 TRANSFORMER FOR STATION ID PANEL LAMPS a ew.otak.com <br /> m3 (11; iN INSTALL ONE TRANSFORMER FOR:THE INFORMATION PANEL 719 Second Ave.Suite 1250 32130T <br /> ▪ 24V TRANSFORMER 2 X X D KS Project No. <br /> m LIGHTS(INCLUDE ONE SPLITTER)AND ICONIC MARKER SealBe,WA 98104 El .02 <br /> ' NETWORK VIDEO RECORDER 1 X X X POWER AND COMM FOR FUTURE INSTALLATION (206)382-9800 <br /> www.dksassociates.com Drawing No. <br /> a "` CONTRACTOR SHALL CONFIRM MAKE/MODELS WITH COMMUNITY TRANSIT IT DEPARTMENT PRIOR TO ORDERING EQUIPMENT. <br />
The URL can be used to link to this page
Your browser does not support the video tag.