Laserfiche WebLink
SH LAYOUT \ A PORTION OF THE NE 1/4 SECTION-26,- T.-28 N., R. 4 E. I CONSTRUCTION NOTES <br /> 03213017091 \ V AIRPORT ROAD <br /> 1OAT_N CONNECT TO EXISTING STRUCTURE. <br /> S130513002 0 <br /> S3211307B190 os (;)INSTALL 3"CONDUIT FOR FUTURE <br /> S32130U9190 COMMUNICATION CONNECTION.TERMINATE CONDUIT <br /> 0321301Y220 \ AT EMPTY TYPE 1 UTILITY JUNCTION BOX <br /> ! 00„.„ <br /> 0 0 STA 10+86.30,7.68'8 ADJACENT TO PLATFORM. SEE SHEET C6.04 FOR <br /> 53213007220 \ CB6EXIST. <br /> 0WASSEAL321301 ° UTILITY TRENCH DETAILS. <br /> C32130TN03 RIM=493.75 <br /> C321301n03a IE=489.49(12"SDS OUT <br /> c3213000-UTIL \\. CB630,EXIST.TYPE 1 C8631,TYPE 1 ) ADJUST EXISTING UTILITY TO FINISH GRADE. <br /> 032 3000-STRM 05 STA 9+41.23,4.70'R 1 3 STA 10+10.01,0.84'L IE=489.49(12"EXIST. NW IN) <br /> 4 CONNECT STORM DRAINAGE TO STUB AT STATION <br /> RIM=491.20 RIM=492.32 COLUMN. SEE SHEET C6.04 FOR.DETAILS. <br /> \\ IE=485.80(12"EXIST.E OUT) IE=488.72 (12"SO SE OUT) 77LF'12°SD o <br /> \' IE=486.00(12"EXIST.NE OUT) IE=488.97(6"PVC NE IN) 5=1.00% p INSTALL TYPE 1 UTILITY JUNCTION BOX PERvi <br /> WSDOT STD PLAN J-40.10-04. rc <br /> \ IE=486.00(12"SD T. IN) IE=488.72(12"SD N IN) m _ a <br /> IE=485.30(12"EXIST.S IN) <br /> 6 EXISTING UTILITY TO BE RELOCATED BY OTHERS. , <br /> \ 59 3.94% SO J 7�REMOVE EXISTING GRATE AND INSTALL SOLID LID . -P <br /> \ \ SDCB PER WSDOT STD PLAN B-30.20-02. m <br /> RIM = 492.99 I BO RELOCATE EXISTING UTILITY. <br /> \ 2,.CCNC(N) =489.49 <br /> ' �` 11t110 '� 6LF 6"PVC 2"CONC(S) = 489.59 \ O O OUTLET 3"STORM DRAIN PIPE THROUGH CURB <br /> \ \`,� �\ S=60.00% CTR = 488.59 \ .1 PER DETAIL ON SHEET C6.04. o <br /> \\11 '.:*'' ''' \� W 10 INSTALL CONDUIT TO WITHIN 2'OF EXISTING PUD - -- - <br /> , Crl ELECTRIC JUNCTION BOX WITH 5'OF CABLE '2 <br /> +a0 1 '1 ' 0 , 10 00 T 1_ \ 11+00 <br /> \--,- <br /> \ 1 Q/ ),- <br /> lir <br /> , \- .� -- -�_ y 8 �y 5 COILED. PUD W JUNCTION BOX,COMPLETE TCOMPLETE HECONNEDUIT CTIONON AND <br /> >> 3 ` NF-� ENERGIZE THE CIRCUIT. �.<g <br /> A -40 <br /> 11 INSTALL INSTALL 3"CONDUIT WITH 3 6 rot si�♦ <br /> �,_ CONDUCTORS STATION SERVICE),AND 4 HE - le R_ & <br /> _ 7-"7 1 - O u O CONDUCTORS RESTROOM SERVICE).SE SHEET / <br /> \ /� C�� f`--� �� W 06.04 FOR UTILITY TRENCH DETAILS. I,I r`% <br /> -..__. ........m..._ 12 I 6 <br /> , \ <br /> .0 ., \\ I SEE SHEET C6.04U FORITtrri TRENCH DETAILS. <br /> \ h �' ,.).„.4 <br /> \\ P P P P P P P P 4I v, 13 CONDUIT SHALL BE INSTALLED BY DIRECTIONAL �24/I7`4q � 8"x 74"S.C= - r-- r�=R�"= j:8: <br /> CROSS ROADWAY. <br /> YIELD" / \\\\ RM 9120. \.J\\ EXIST.UTILITY. // � / \ 2 0`+ N) = 465.92 -- - - 14 ATERMAIN WIPER TH APPURTED STDS. CNANCECT TO <br /> 9 \ \ POLE 1-32 /A / L COti. (Ll 486.00 Q <br /> \\ //'4 . h) 41/ <br /> % (SSE) 485 SC <br /> \ \ ,/ '` CO\"' `N) 485'30 15 STD PCLAN TYPE <br /> 50.12-OCTION LOOPS PER WSDOT <br /> 'DC6 �.' OTR = 4x4.60 O <br /> P:M - 4926-\ 9' /� �\' 0 I 18 INSTALL WETLAND TREATMENT CATCH BASIN,SEE <br /> \\ \ -_ ' // <br /> / DETAILS ON SHEET 04.36. Z <br /> \ J, TEMPORARY CONSTRUCTION17 INSTALL 48"SRSSP DETENTION TANK PER 2016 O <br /> o` �j'��%� // EASEMENT ® 0 ,..... O SNOHOMISH COUNTY EDDS 5-290 <br /> iii I 18 RELOCATE EXISTING MECHANICAL GATE AND F <br /> \ JUNCTION BOX TO BE O <br /> r/L INSTALLED BY PUD INSTALL 6'X 12'DETECTION LOOPS PER WSDOT <br /> \ \ /II ! STATION/3021 - STD PLAN J-50.11-00 AND J-50.15-00 AND U <br /> \\ i ri/ 11831 AIRPORT ROAD EVERETT,WA 98204 SPECIFICATIONS.LOCATION TO BE STAKED BY <br /> \\5 ( i ENGINEER. <br /> \�\`�,r � . �: 19 REMOVE AND RELOCATE EXISTING LUMINAIRE PER <br /> \ WA ' SPECIFICATIONS.CONSTRUCT TYPE A FOUNDATION r^ <br /> FOR STEEL LIGHT STANDARD WITH SLIP BASE PER VJ <br /> WSDOT STD PLAN J-28.30-03. Z ^ <br /> 0 REMOVE AND RELOCATE EXISTING PEDESTRIAN O <br /> SCALE OR PRIVATE PARKING LOT LIGHT.SEE (V <br /> SPECIFICATIONS. U 9, <br /> 0 INSTALL 12"DIP,PER SLSWD STDS. CONNECT TO <br /> EXISTING WATERMAIN WITH APPURTENANCE SHOWN <br /> 0 INSTALL FLOW RESTRICTION/OIL POLLUTION - 0 z <br /> a (FROP) CONTROL DEVICE PER 2016 SNOHOMISH F 0 <br /> U COUNTY EDDS 5-270A&5-270C. <br /> AIRPORT ROAD ©INSTALL DETAIL OINFILTRATION <br /> SH STI 4N37HAMBER GALLERY PER . Q N <br /> z f��//�� <br /> 3 7 ©Q `+PLAN,SEE SHEET INSTALL BIOFILTRATION SIZE PER VJ <br /> aN #74 I CD) <br /> (4) 4"PWR CB 20'X24" 0) <br /> 08633,TYPE 2-48" TOP = 492.15 RILL = 495.69 ON W <br /> a STA 11+92.81,2.38'8 -) �IE 12"CONC )- <br /> BG = 491.73 (N 490.39 LEGEND Z C <br /> M RIM=494.31 1 IE 12"CONC(ENE)=490.30 (n <br /> IE=490.79 (12"EXIST.SE OUT) j ------ EXISTING RAV - Letl/ J I- <br /> c2 W IE=490.79(12"EXIST.NW IN) PH #6 1 <br /> 1 > 9.98 5 8'CCM ----- Q <br /> RiM = 4„4.98_ i l - RAV EASEMENT ` Z <br /> 12"CONC (S) = 491.4$ \1 TOP = 493.36-- t / ^ W o <br /> m ClR_ 490.56. \ \ -' PROPERTY LINE = <br /> Lc...! t / _ PERMANENT EASEMENT W zI- <br /> 3 LL <br /> / -- -- UTILITY EASEMENT <br /> CO12+00 <br /> ' -J ....._ _. ... ------ -_-_ -- \ -.. 'r- .... - - TEMPORARY CONSTRUCTION EASEMENT - �� <br /> - --..7.------- <br /> :54 <br /> - ...._ .... _ .. ..,.. 1 P POWER <br /> 1166_n W .' --- 1 / __P. i r ..., i T COMMUNICATION - O 3-I <br /> e J/ tel,o _ z <br /> 2 II <br /> r <br /> x0 I ii ,---- I' R/W • <br /> \ 'V1 <br /> L ,-,(u71 \ ___-- <br /> N. M --M_------...- Mt-- W--- -14 _ Ii <br /> E G -J i `J is <br /> / / i I Ha nNGbbal Partner <br /> a <br /> n / / I NOV LANE / <br /> ✓i 11241 Mows Road NE <br /> / '' Suite 200 <br /> -RCHT LANE / Redmond,lashinglon 96052 <br /> i 0•EDESTAL / / Ph0one:(425)822-4446 <br /> n R/W EASEMENT /',. / PLAZA S.GN , FAX:(425)827-9577 <br /> E www.otak.com <br /> N <br /> N - TEMPORARY / 321307 <br /> CONSTRUCTION !!! Project No. <br /> EASEMENT ‘41:1 / <br /> 10' 0' 10' 20' C4.29 <br /> 2 MOINIIIIIIMII <br /> M M Drawing No. <br /> J/ SCALE IN FEET <br />