Laserfiche WebLink
ohm resistor. At the near end, an HP-3551 or equivalent transmission measuring set should be configured for <br /> conducting a noise reading test. Cable pairs being sampled shall provide an ambient noise figure of 30 DbmO (-60 <br /> dBm) or better. The Contractor shall record all readings. <br /> Shield Continuity- Test and measurements shall be made to assure that all underground cable shields are <br /> continuous from end-to-end. Each shield shall show a resistance of not more than .75 ohms per 1000 feet. <br /> Within 30 days of submitting the test results, the Contractor,in the presence of the Engineer, shall re-test a <br /> minimum of 5% of the previously tested locations to validate the test results. A 5% sample will be selected <br /> randomly from the terminal device locations. <br /> 9-29.6 Light And Signal Standards <br /> Section 9-29.6 is supplemented with the following: <br /> ***To Be Determined*** <br /> 9-29.10 Luminaires <br /> Section 9-29.10 is supplemented with the following: <br /> ***To Be Determined*** <br /> Luminaires installed on traffic signal mastarms in conjunction with the bid item, "SR 527 at 208`'' Street SE (SR <br /> 524) Traffic Signal Modifications, Complete" shall be City of Bothell/Snohomish County-approved 400W HPS <br /> LED Equivalent. <br /> Luminaires installed on new light standard in conjunction with the bid item, "Airport Road BAT Lane Illumination <br /> System, Complete" shall be Leotek EC7-24M-MV-MW-3-GY-700, or other Snohomish County-approved <br /> equivalent. <br /> 9-29.10(5) C Internally Illuminated Street Name Signs (New Section) <br /> The overhead street name signs (Type D3-301) provided for the project shall be internally illuminated and have 12" <br /> capital letters and 9" lowercase letters per MUTCD. The signs shall be a maximum of 22"in height and the length <br /> will vary depending on street name, to a maximum of 120". The light panel shall be enclosed in an aluminum <br /> frame for mounting and support purposes. The light panel shall employ energy-efficient LED technology. The <br /> Panel shall have standard green or brown (recreational) backgrounds per the plans. <br /> All Internally Illuminated Street Name Signs supplied for the project shall be Temple Edge-Lit R409A-XXX-HH- <br /> LL or Bothell/Snohomish County Approved Equivalent prior to close of bid. A <br /> Mechanical Specifications <br /> The maximum thickness of the sign shall be 1.60 inches, as measured front-to-back, to include the end cap. <br /> End caps shall be used to secure both ends of the signs and all internal components, and each end cap shall be <br /> fabricated using a single sheet of 0.090" thick Type 5052-H32 grade aluminum. <br /> 35 <br /> Swift II BRT Boeing to Canyon Park Station —Traffic Signal 90% Special Provisions— 12/1/2016 <br />