My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11831 AIRPORT RD WHOLE SITE FILE 2020-01-21
>
Address Records
>
AIRPORT RD
>
11831
>
WHOLE SITE FILE
>
11831 AIRPORT RD WHOLE SITE FILE 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 11:19:57 AM
Creation date
6/18/2019 1:36:16 PM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
11831
Tenant Name
WHOLE SITE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
534
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
If, in the opinion of the Engineer, personnel used for installing pervious concrete are unqualified, <br /> inattentive to quality, or unsafe, they shall be removed or reassigned from installation of <br /> pervious concrete at the written request of the Engineer. <br /> 5-06.3(10)B Test Panel <br /> Production placement of pervious concrete shall not occur until the Contractor has completed a <br /> test panel of pervious concrete pavement that meets all of the acceptance criteria described <br /> herein and is accepted by the Engineer. <br /> The Contractor shall construct a test panel utilizing a minimum of seven (7) cubic yards of <br /> pervious concrete. If multiple pavement section depths are shown on the plans, a test panel <br /> shall be constructed for each pavement section depth/thickness. The width of the test panel <br /> shall have a width no smaller than the greatest width to be used during the construction and <br /> installation of the pervious concrete onsite. The test panel(s) shall include at least one joint and <br /> at the spacing specified on the plans and specifications. Test panels may be placed non- <br /> contiguously. The test panel(s) shall be equivalent and representative of the production pervious <br /> concrete pavement in all aspects including subbase, depth,joints, method of placement, curing, <br /> and preparation. Construction and evaluation of the test panel shall occur as follows: <br /> 1. Notify the Engineer at least ten (10)Working Days before installing pervious <br /> concrete test panels. <br /> 2. Coordinate the location of the test panel with the Engineer. <br /> 3. Install the test panel in accordance with the Specifications and Drawings. <br /> 4. Notify the Engineer when the test panel is ready for inspection and acceptance <br /> testing. <br /> 5. Acceptance testing will be conducted in accordance with Section 5-03.3(6). <br /> 6. Remove, replace, and dispose of any unsatisfactory portions of test panels as <br /> determined by the Engineer, at no additional cost to the Contracting Agency. <br /> Failure to install acceptable test panel(s) of pervious concrete will indicate an unapproved test <br /> panel(s) and require new test panel(s) for review. <br /> The completed and approved test panel(s) shall establish the JMF. <br /> The approved test panel shall meet the requirements of Section 5-03.3(6). <br /> Upon successful completion of the infiltration test, unless otherwise determined by the Engineer, <br /> three (3), cores will be cut in accordance with ASTM C42 and will be used to validate the mix <br /> design under the acceptance criteria of Section 5-06.3(6). Cores shall be taken at the same <br /> location where the infiltration test was conducted. The average hardened density of the cores <br /> shall be the hardened density used for the JMF. The hardened density of each core used for <br /> determining the JMF shall be within five (5) percent of the mean value of the three cores. Core <br /> holes shall be filled by the Contractor with pervious concrete meeting the proposed JMF and <br /> shall match adjacent pavement color, texture and grade. <br /> The completed and accepted test panels shall be maintained and protected throughout the <br /> duration of the Work and may not be demolished and disposed of without written permission <br /> Swift Green Line—Corridor Stations Special Provisions SP85 <br /> May 2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.