4/2/2019 Page <br /> City of Everett <br /> 11:37:51AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. M1808-108 Site Address 1312 BALLEW AVE <br /> Applied 8/31/2018 Applicant Lot <br /> Approved 8/31/2018 Owner ROBERTS DEEDEE Block <br /> Issued 8/31/2018 Contractor DAY&NITE PLG&HTG INC Tract <br /> Parent Permit No. Description REPLACE FURNACE,INSTALL GAS PIPING METER TO FURP <br /> Notes GAS LINE FOR NEW RANGE <br /> Scheduled Completed Tune Inspector Result Remarks Inspector's Comments <br /> 9/5/2018 9/5/2018 GAS 01-ROUGH IN SDP APPROVAL Gaspipe tested at 15psi.OK for service. <br /> 9/6/2018 9/6/2018 MECH 06-FINAL DXW CORRECTION 1.B vent must be 1"clear of all <br /> combustables-metal on wood does not meet <br /> code. <br /> 2.Inspection needs to see clearance in wall <br /> and insulation shield required.Where <br /> B-vent goes thru wall. <br /> 4/1/2019 4/1/2019 MECH 06-FINAL DXW APPROVAL as noted comp. 1 in <br /> air gap at shield <br /> 4/1/2019 4/1/2019 ADMIN USE KLC APPROVAL <br /> ONLY** <br /> INSP12 C W"S YSTEMS <br />