f � <br /> with a bulkhead enclosure, the bulkhead enclosure shall comply with Section R310.3. <br /> The net clear opening dimensions required by this section shall be obtained by the <br /> normal operation of the emergency escape and rescue opening from the inside. <br /> Emergency escape and rescue openings with a finished sill height below the adjacent <br /> ground elevation shall be provided with a window well in accordance with Section <br /> R310.2. Emergency escape and rescue openings shall open directly into a public way, or <br /> to a yard or court that opens to a public way. <br /> 5. In combustible construction, fireblocking shall be provided to cut off all concealed draft <br /> openings (both vertical and horizontal) and to form an effective fire barrier between <br /> stories, and between a top storyand the roof space. Provide fireblocking in required <br /> locations, show on section drawings. <br /> 6. R302.7 Under-stair protection. <br /> Enclosed accessible space under stairs shall have walls, under-stair surface and any <br /> soffits protected on the enclosed side with 1/2-inch (12.7 mm) gypsum board. <br /> 7. Provide Site plan per City of Everett Residential Submittal Checklist Show all information <br /> required on checklist, including but not limited to driveway and sidewalks. Impervious <br /> area calculation shall include driveway and sidewalks. <br /> 8. Walls located less than 5'-0"from the property line are required to be one-hour fire- <br /> resistant construction. Provide section and detail for one-hour fire-resistant assembly <br /> (if applicable) <br /> 9. R311.7.8 Handrails. <br /> Handrails shall be provided on at least one side of each continuous run of treads or <br /> flight with four or more risers. Show continuous handrail on plans. Handrails shall be <br /> returned or shall terminate in newel posts or safety terminals. <br /> 10. Show how all spaces in the basement are provided with natural light per section R303.1 <br /> R303.1 Habitable rooms. <br /> All habitable rooms shall have an aggregate glazing area of not less than 8 percent of <br /> the floor area of such rooms. <br /> 11. Show how the dwelling unit is provided with energy Credits per section R406 and Table <br /> 406.2 of the Washington State Energy Code (WSEC). There are 0.5 credits required for <br /> this addition. <br /> 12. R314.3.1 Alterations, repairs and additions. <br /> When alterations, repairs or additions requiring a permit occur, or when one or more <br /> sleeping rooms are added or created in existing dwellings, the individual dwelling unit <br /> shall be equipped with smoke alarms located as required for new dwellings. <br /> 5 <br /> /) <br /> S:\1Common\Clerical\]Heilman\C1604-127(8009 Beverly Blvd).doc <br />