Laserfiche WebLink
LEGEND <br /> -- -- -- -- -- — <br /> CONSTRUCTION NOTE <br /> PROPOSED ITEM <br /> II ._..---- <br /> I EXISTING ITEM <br /> /ak\ WIRE NOTE <br /> f® LUMINAIRE AND POLE <br /> I I ——J—�C— — NEW CONDUIT <br /> EXISTING CONDUIT <br /> ---------- TRENCHING <br /> I I m TYPE 1 JUNCTION BOX <br /> GENERAL NOTES <br /> 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH BOEING STANDARDS,MANUAL ON <br /> UNIFORM TRAFFIC CONTROL DEVICES(MUTC)),AND WSDOT STANDARDS AND <br /> I SPECIFICATIONS. <br /> I <br /> 2. THE LOCATIONS OF FEATURES SHOWN SHALL BE VERIFIED IN THE FIELD BY THE <br /> CONTRACTOR PRIOR TO CONSTRUCTION WORK. <br /> 3. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS.THE <br /> CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS PRIOR <br /> 1 TO COMMENCING WORK,AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES <br /> I THROUGHOUT THE PROJECT. <br /> 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. <br /> THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY <br /> . IMMEDIATELY UPON DAMAGE AND BE RESPONSIBLE FOR REPLACING ANY DAMAGED <br /> _---e ■ I' __- 1 EQTHEUIPMECitt.NT TO THE SATISFACTION OF THE AFFECTED UTILITY COMPANY AND/OR <br /> I <br /> 1 I 5. JUNCTION BOXES AND CONDUIT ARE SHOWN SCHEMATICALLY.LOCATIONS AND <br /> ELEVATIONS MAY BE FIELD ADJUSTED TO AVOID CONFLICTS AS DIRECTED BY THE <br /> I <br /> _ .,: ENGINEER. <br /> - 6. ORIENT LUMINAIRE 235 DEGREES CLOCKWISE FROM TRUE NORTH. <br /> - '- - 7 1 N. <br /> , , , , , 1 1 1 IF- 1�ti 7 WORKTURN OFF ON NEWEU/STING 55 RANKING SYSTEM <br /> ILLUMINA iK)N SYSTEM PRIOR TO COMMENCING <br /> 11, <br /> r 8. THE CONSTRUCTION CONTRACTOR SHALL DELVER RED-LINED DRAWINGS TO THE <br /> —11-11F . ,.._.. ^� 1RlA\ ' BOEING AUTHORIZED REPRESENTATNE WITHIN TEN(10)WORKING DAYS FROM THE <br /> ,N� _ - - W, ` COMPLETION OF CONSTRUCTION. <br /> .r <br /> o I _____ - - ----� CONSTRUCTION NOTES <br /> \ JT1JP • [>INTERCEPT EXISTING CONDUIT WITH NEW TYPE 1 JUNCTION BOX. <br /> ` SPLICE EXISTING CONDUCTORS WITH NEW CONDUCTORS IN <br /> V �, - s _- JUNCTION BOX. CONTRACTOR SHALL ENSURE JUNCTION BOX IS <br /> I <3 i�� . 1 INSTALLED ABOVE FLOW LINE. <br /> = 4i_,A.....,• � INSTALL CONDUIT PER DETAIL N ON SHEET C220-23D. MAINTAIN <br /> ' .1"..„... <br /> � •/f ; INS:An 2FT MINIMUM CLEARANCE FROM ONEXISTINGSHE STORM PIPE. <br /> I !:::::::ikri <br /> / _ 1"C,2-#8&1-#8G <br /> a <br /> >INSTALL NEW TYPE 1 JUNCTION BOX PER WSDOT STANDARD <br /> I ���� 4 � I � "~�A V \\ PLAN J-40.10-04. CONTRACTOR SHALL ENSURE JUNCTION BOX <br /> 1 �E -,? . .\ I IS INSTALLED ABOVE FLOW LINE. <br /> ! I �z. �► X. Y. 1"C,H8& 1-#8G ®INSTALL NEW STREET LIGHT POLE(LTRA35-8250), LUMINAIRE AT <br /> g. 1 I • . �q 35 MOUNTING HEIGHT.SEE SHEET E508 FOR LUMINAIRE, POLE, <br /> Y <br /> 1 ---- _ " �. AND MOUNTING HEIGHT DETAIL. INSTALL FOUNDATION PER WSDOT <br /> 1 Pa ,�` ',_ I E 1287442.4! ' ,`0 TO 4 c I <br /> -'N' STANDARD PLAN J-28.30-03. <br /> REFERENCE DRAWINGS <br /> 1"C,2-18& 1-#BG 1. REFERENCE DRAWING 45-YD-E514. <br /> 2. REFERENCE DRAWING 45-YD-E508. <br /> 3. REFERENCE DRAWING 45-YD-E559. <br /> 1 1 1�: <br /> 1 I YII�� - <br /> X111.1 i f <br /> 1111ll�if�!►L±' ri <br /> I <br /> s lo imiglin <br /> �' <br /> Q Idu. <br /> • <br /> I fl 22 , _!:.,..._ <br /> II <br /> ISSUED FOR ��jT�.I <br /> CONSTRUCTION LJ <br /> ---- -- ----- -- -- -- -- -- -- - KEY PLAN <br /> INTERSECTION PLAN N transpogroup yr SCALE NONE <br /> CI) <br /> O 40 20 0 20 40 80 <br /> SCALE: 1" = 10 WHAT TRANSPORTATION CAN BE. —=—=- <br /> 12131 113TH AVENUE NE,SUITE 203 (TEL)425 821-3665 2—� 04 <br /> KIRKLAND,WASHINGTON 98034 (FAX)425825-8434 SCALE: 1:40 <br /> SYM REASON BI APPROVED DATE 5001 REVISOR BY APPROVED DATE <br /> ACCEPTABILITY .- 08.04.17 SUBTILE CURRENT REVISION SYMBOL DATE <br /> - - - _,,q R.Coc, THIS DESIGN AND/OR CHECKED LIGHTING 08.04.17 <br /> /w— SPECIFICATION IS APPROVED BMK 08.04.17 SHEET <br /> — OE/Ni/ ® �� " APPROVED B DEP. CATE <br /> ENGINEER <br /> RC EER 08.04.17 94TH ST SW CURB EXTENSION E1 0-23 <br /> el.__A! /• "CHECKED <br /> - SITE 45-YD .KB NO COMP NO. <br /> APPROVED <br /> APPROVED 00c NO. <br /> ELECTRICAL MASTER EVERETT, WA 45-YO-E10-23 <br />