My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2714 COLBY AVE ROMIOS PIZZA 2019-06-24
>
Address Records
>
COLBY AVE
>
2714
>
ROMIOS PIZZA
>
2714 COLBY AVE ROMIOS PIZZA 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 9:57:14 AM
Creation date
6/24/2019 9:57:05 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2714
Tenant Name
ROMIOS PIZZA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBLIC WORKS <br /> October 11, 2017 <br /> Kostadin Kostadinov <br /> 4133 122nd PL SE <br /> Everett, WA 98208 <br /> Owner: JEKO LLC <br /> Job Address: 2714 Colby Ave <br /> Plan Check No: M1710-012 <br /> RE: Corrections Letter <br /> Dear Mr. Kostadinov, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> General <br /> 1. The location of the roof-top make-up air unit and distance to the exhaust fan unit, type I <br /> hood and property lines, should be shown on the plans. IMC Section 508.1 <br /> 2. All ceiling tiles within 18"of the hood are required to be non-combustible. Verification is <br /> required. IMC Section 507.2.6 <br /> 3. The structure and lateral bracing supporting the hood should be detailed on the plans. <br /> IMC Section 301.15 <br /> 4. The exhaust fan should be shown with required side-hinge and flexible cable per IMC <br /> Section 506.5.3 <br /> 5. Please indicate the slope of the roof on the plans. If it is greater than 3:12, then a <br /> platform and guard complying with IMC Section 306.5.1 will be required for each new <br /> piece of roof-top appliance/equipment. <br /> 6. The equipment on the roof is shown to be greater than 16 feet above grade. A <br /> permanent access ladder complying with Section 306.5 should be detailed on the plans. <br /> All codes cited refer to the 2015 International Building Code (IBC), the 2015 International Fire <br /> Code (IFC), the 2015 International Mechanical Code (IMC), and the 2015 Washington State <br /> Energy Code (WSEC), as amended by the State of Washington and adopted by the City of <br /> (7// <br />
The URL can be used to link to this page
Your browser does not support the video tag.