My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6002 COMMERCIAL AVE 2019-06-24
>
Address Records
>
COMMERCIAL AVE
>
6002
>
6002 COMMERCIAL AVE 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 11:04:44 AM
Creation date
6/24/2019 11:04:33 AM
Metadata
Fields
Template:
Address Document
Street Name
COMMERCIAL AVE
Street Number
6002
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C. NOTCHES AND HOLES IN MANUFACTURED LUMBER AND PREFABRICATED PLYWOOD WEB NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER FOR MAXIMUM LOAD <br /> JOISTS SHALL BE PER THE MANUFACTURERS RECOMMENDATIONS UNLESS OTHERWISE CARRYING CAPACITY. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br /> NOTED. MANUFACTURER'S RECOMMENDATIONS. <br /> - 29. WOOD FRAMING NOTES--THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE ALL 2X JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST <br /> PLANS: HANGERS. ALL TJI JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "ITS" <br /> SERIES JOIST HANGERS. ALL DOUBLE-JOIST BEAMS SHALL BE CONNECTED TO FLUSH <br /> A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO BEAMS WITH "MIT" SERIES JOIST HANGERS. <br /> THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE AITC <br /> "TIMBER CONSTRUCTION MANUAL" AND THE AF&PA "NATIONAL DESIGN WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS <br /> SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM NAILING, UNLESS OR BOLTS IN EACH MEMBER. <br /> OTHERWISE NOTED, SHALL CONFORM TO IBC TABLE 2304. 10.1. COORDINATE THE <br /> SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM)AS <br /> DRAWINGS. MEMBERS CONNECTED. <br /> B. WALL FRAMING: REFER ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS. 27. WOOD FASTENERS <br /> ALL STUDS SHALL BE SPACED AT 16" O.C. UNO. TWO STUDS MINIMUM SHALL BE <br /> PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AND A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING <br /> AT BEAM OR HEADER BEARING LOCATIONS. TWO 2x8 HEADERS SHALL BE PROVIDED SPECIFICATIONS: <br /> OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COLUMNS <br /> SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE CONTINUOUS SIZE LENGTH DIAMETER <br /> SOLID BLOCKING AT MID-HEIGHT OF ALL STUD WALLS OVER 10'-0" IN HEIGHT. 6d 2" 0.113" <br /> 8d 2-1/2" 0.131" <br /> ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END 10d 3" 0.148" <br /> NAIL TOP PLATE TO EACH STUD WITH TWO 16d NAILS, AND TOENAIL OR END 12d 3-1/4" 0.148" <br /> NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16d NAILS. FACE NAIL DOUBLE 16d BOX 3-1/2" 0.135" <br /> TOP PLATE WITH 16d @ 12" O.C. AND LAP MINIMUM 4 '-0" AT JOINTS AND <br /> PROVIDE EIGHT 16d NAILS @ 4" O.C. EACH SIDE JOINT. IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT <br /> NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) <br /> ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FOR REVIEW AND APPROVAL. <br /> FRAMING BELOW WITH TWO ROWS OF 16d NAILS @ 12" ON-CENTER, OR ATTACHED <br /> TO CONCRETE BELOW WITH 5/8" DIAMETER ANCHOR BOLTS @ 4'-0" ON-CENTER NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE <br /> EMBEDDED 7" MINIMUM, UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. <br /> BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH TWO ROWS OF 16d @12" TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DIGRESS WITH THE MEMBER <br /> ON-CENTER. UNLESS OTHERWISE NOTED, GYPSUM WALLBOARD SHALL BE FASTENED AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END. <br /> TO THE INTERIOR SURFACE OF ALL STUDS AND PLATES WITH NO. 6 X 1-1/4" <br /> TYPE S OR W SCREWS @ 8" ON-CENTER. UNLESS INDICATED OTHERWISE, 1/2" B. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307 . PROVIDE WASHERS <br /> (NOMINAL)APA RATED SHEATHING (SPAN RATING 24/0) SHALL BE NAILED TO ALL UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD. <br /> EXTERIOR SURFACES WITH 8d NAILS @ 6" ON-CENTER AT PANEL EDGES AND TOP INSTALLATION OF LAG BOLTS SHALL CONFORM TO THE NATIONAL DESIGN <br /> AND BOTTOM PLATES (BLOCK UN-SUPPORTED EDGES)AND TO ALL INTERMEDIATE SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60 TO 70 <br /> STUDS AND BLOCKING WITH 8d NAILS @ 12" ON-CENTER ALLOW 1/8" SPACING AT PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" <br /> ALL PANEL EDGES AND PANEL ENDS. AND SMALLER LAG SCREWS. <br /> C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL 28. NOTCHES AND HOLES IN WOOD FRAMING: <br /> PARTITIONS THAT EXTEND OVER MORE THAN HALF THE JOIST LENGTH AND AROUND <br /> ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE SOLID A. NOTCHES ON THE ENDS OF SOLID SAWN JOISTS AND RAFTERS SHALL NOT EXCEED <br /> BLOCKING AT ALL BEARING POINTS. TOE-NAIL JOISTS TO SUPPORTS WITH TWO ONE-FOURTH THE JOIST DEPTH. NOTCHES IN THE TOP OR BOTTOM OF SOLID SAWN <br /> 16d NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH SIMPSON JOISTS SHALL NOT EXCEED ONE-SIXTH THE DEPTH AND SHALL NOT BE LOCATED <br /> METAL JOIST HANGERS IN ACCORDANCE WITH NOTES ABOVE. NAIL ALL MULTI IN THE MIDDLE THIRD OF THE SPAN. HOLES BORED IN SOLID SAWN JOISTS AND <br /> JOIST BEAMS TOGETHER WITH TWO ROWS 16d @ 12" ON-CENTER. RAFTERS SHALL NOT BE WITHIN 2 INCHES OF THE TOP OR BOTTOM OF THE <br /> JOIST, AND THE DIAMETER OF ANY SUCH HOLE SHALL NOT EXCEED ONE-THIRD <br /> UNLESS OTHERWISE NOTED ON THE PLANS, PLYWOOD ROOF AND FLOOR SHEATHING THE DEPTH OF THE JOIST. <br /> SHALL BE LAID UP WITH GRAIN PERPENDICULAR TO SUPPORTS AND NAILED AT 6" <br /> ON-CENTER WITH 8d NAILS TO FRAMED PANEL EDGES, STRUTS AND OVER STUD B. IN EXTERIOR WALLS AND BEARING PARTITIONS, ANY WOOD STUD IS PERMITTED <br /> WALLS AS SHOWN ON PLANS AND @ 12" ON-CENTER TO INTERMEDIATE SUPPORTS. TO BE CUT OR NOTCHED TO A DEPTH NOT EXCEEDING 25 PERCENT OF ITS WIDTH. <br /> PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT A HOLE NOT GREATER IN DIAMETER THAN 40 PERCENT OF THE STUD WIDTH IS <br /> UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE PERMITTED TO BE BORED IN ANY WOOD STUD. IN NO CASE SHALL THE EDGE OF <br /> APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW THE BORED HOLE BE NEARER THAN 5/8 INCH TO THE EDGE OF THE STUD. BORED <br /> 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SHEATHING. HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A CUT OR <br /> TOENAIL BLOCKING TO SUPPORTS WITH 16d @ 12" ON-CENTER UNLESS OTHERWISE NOTCH. <br /> NOTED. <br /> S3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.