Laserfiche WebLink
ica.,-PINse include both the interior and the exterior lightingtin the lighting summary and analysis <br /> g the LIGHT-SUM form, per WSEC table C405.5.2 (1).This WSEC form should be submitted <br /> t•ti as part of the tenant improvement. <br /> 0 \ Response:See attached WSEC form that corresponds with the Ceiling Legend on sheet A2.2. <br /> 1`w� ,n b. Please include actual'code section language on the drawings for interior and exterior lighting <br /> �6151 controls, sensors, and anther—Tr-mpliance covered in electrical power and lighting <br /> systems per WSEC section C405. <br /> Zo��s Response:See Ceiling and Lighting Notes A through C,Sheet A2.2. <br /> Gar w0-sl" Q (6.04 7/>>/ti) <br /> 2. Please identify if theoccupancy is semi-heated, per WSEC section C402.1.1.1, or low energy <br /> path, which requires documentation on the plans for the intent for use and heating of the space <br /> i per one of the four options summarized in WSEC section C402.1.1. <br /> % Response:The occupancy for the Customer Service areas& the Car Wash& Detail bays are both B. <br /> See note added to Reflected Ceiling Plan,Sheet A2.2 and attached completed Energy Compliance <br /> Forms. e d ern,,ft <br /> P2-011-71517 � -fot,. cAl2 L.-.frs+1, Q/") cogi".s <br /> 3. A change to the space conditioning of the building to heated, semi-heated or to non-conditioned, <br /> may require replacement and modification of existing mechanical equipment and fenestration, per <br /> IEBC C503.2.This potentially impacts the new office area,the basement, and the new vehicle <br /> servicing area, more than what is already shown on the plans. <br /> Response:The Scope of work is outlined on the Levels of Insulation (moved to sheet A2.1)and <br /> Envelope Assembly summary and Floor Plan, sheet A2.1 which states and indicates that all <br /> insulation iri the floor above the basement, above grade walls and roof, along with all of the new <br /> doors and windows are proposed to be replaced and brought up to current prescriptive code. <br /> car c -a S IN C vv,.l-i "7/1.(/1-2 ) <br /> a. For the change of B occupancy to e, please indicate he prescriptive method of <br /> building envelope compliance,to include detailed R-Values of existing or modified interior and <br /> xterior walls, roof-ceiling cavities, man-doors and garage doors, per WSEC section C402.1. <br /> J1, .,..;‘17,4,,,t,_ <br /> l0currently this is shown on the demolition plan only. It would be helpful to have this shown on <br /> nn, 1�V. c'L the sheets indicating new work,or on the cover sheet. <br /> Iv Response: The occupancy for the Customer Service areas and the Car Wash& Detail bays are <br /> both B. See response to#3 above. <br /> S6 b. Please indicate the U values of all existing and new fenestration to meet energy code <br /> o d� e,1' requirements,to include man and rolling doors, per WSEC C402.1.4 and C402.4. <br /> (, RSNi)i Response: This note is called out on the Door& Window Types,sheet AS.1 and references the <br /> Qnvo, t, location of prescriptive requirements as indicated in Levels of Insulation(moved to sheet A2.1) <br /> (�o for all of the proposed doors& windows. <br /> {ii'\ c. Where a change in space conditioning is triggering new work, compliance with the building <br /> (I thermal envelope requirements should be shown both in section and summarized on the <br /> drawings, per WSEC section C503.1. Please indicate the method of building envelope <br /> compliance by completing a total UA alternative worksheet, or provide a completed <br /> prescriptive worksheet to include detailed R-Values of new exterior walls, roof-ceiling details, <br /> slab on grade and foundation details, per WSEC section C402.1. <br /> Response:See attached completed Energy Compliance Forms. <br /> 7-' <br /> Page 3 of 4 16198 SE 48th Drive I Bellevue,WA 98006 I 425.830.3245 <br /> 17-17_city comment response_170709 tg.architect@comcast.net I www.tkgarchitect.com <br />