My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
430 SW EVERETT MALL WAY ENTERPRISE RENT A CAR 2019-06-24
>
Address Records
>
SW EVERETT MALL WAY
>
430
>
ENTERPRISE RENT A CAR
>
430 SW EVERETT MALL WAY ENTERPRISE RENT A CAR 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 2:51:22 PM
Creation date
6/24/2019 2:51:07 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
430
Tenant Name
ENTERPRISE RENT A CAR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Component Performance Path, pg. 2 ENV-UA <br /> . 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: ENTERPRISE RENT-A-CAR TI Date 07/09/2017 <br /> Fenestration Area as%gross above-grade wall area Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3.0% <br /> Building Component Proposed UA Target UA <br /> Ins.R Plan/Detail# F-factor Source&Table#8 F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> ami EXISTING SLAB ON GRADE, <br /> R= D2.1,A2.1 0.540 <br /> 8) INSULATION UNKNOWN. <br /> ° s R= Slab-On-Grade F-0.54 <br /> c <br /> o R= <br /> m 0 R= 0.550 <br /> cn m R= Heated Slab-On-Grade F-0.55 <br /> = R= <br /> Schedule ID U-factor Source910 U-factor x Area(A) =UA(U x A! U-factor x Area(A)= UA(U x A) <br /> 0) A2.1,A3.1,A5.1 HOLLOW METAL DOORS 0.370 63 23.3 0.37 I 63 23.3 <br /> a, PRESCRIPTIVE PERFORMANCE Opaque Swing Doors U-0.37 <br /> c <br /> cn <br /> o A2.1,A3.1,A5.1 ;SECTIONAL DOORS 0.340 456 155.0 0.34 456 155.0 <br /> _ PRESCRIPTIVE PERFORMANCE Opaque rollup&sliding U-0.34 <br /> 0 <br /> 0.30 <br /> Non-Metal Frame U-0.30 <br /> c <br /> 0 <br /> Z <br /> o , A2.1,A3.1,A5.1 STOREFRONT WINDOWS 0.38 129 49.0 0.38 129 I 49.0 <br /> o PRESCRIPTIVE PERFORMANCE I Metal Frame, Fixed U-0.38 <br /> 'm <br /> 17) <br /> 0 a 0.40 <br /> o Metal Frame,Operable U-0.40 <br /> @ <br /> N <br /> I <br /> 8 A2.1,A3.1,A5.1 STOREFRONT DOORS 0.60 42 25.2 0.60 42 I 25.2 <br /> c <br /> 2 PRESCRIPTIVE PERFORMANCE Metal Entrance Door U-0.60 <br /> C <br /> 0.50 <br /> co Z a All types U-0.50 <br /> o H <br /> - <br /> Y - <br /> Area' UA Area' UA <br /> Page 2 Subtotal 690 253 690 253 <br /> TO COMPLY-The Proposed Total UA shall not Page 1 Subtotal 5944 238 5944 238 <br /> exceed the Target Total UA. Project Total 6634 491 6634 491 <br /> Component Performance Compliance (UA) UA COMPLIES <br /> Note 1-If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1, then Target Area Adjustment of all applicable envelope <br /> elements will be calculated automatically by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> Note 2-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 3-Proposed CMU mass wall in non-Group R that meet Table C402.1.4 Footnote D requirements can enter the target U-value of 0.014 <br /> Note 4-For semi-heated spaces utilizing the wall insulation exception,enter Target Wall U-factors under Proposed Wall U-factors so exterior <br /> walls are neutral to the calculation. <br /> Note 5-Mass transfer slab edges must be covered with an assembly having an overal U-factor of 0.2. <br /> Note 6-Demising walls, doors,and vertical fenestration separating spaces with different degrees of space conditioning(unconditioned.semi-heated. <br /> fully conditioned)shall be included only on the ENV-UA form for the space with the greatest degree of space conditioning. <br /> Note 7-List Group R above grade mass walls here. List all other mass walls, Commercial and Group R,in the Opaque Walls-Above Grade section. <br /> Note 8 -Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 9 -Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 10-Fenestration assembly U-Factors shall be the manufacturer's NFRC product rating, which includes the glazing and frame,or shall be <br /> the default value per Section C303.1.3. <br /> 0 (J <br />
The URL can be used to link to this page
Your browser does not support the video tag.