My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
430 SW EVERETT MALL WAY ENTERPRISE RENT A CAR 2019-06-24
>
Address Records
>
SW EVERETT MALL WAY
>
430
>
ENTERPRISE RENT A CAR
>
430 SW EVERETT MALL WAY ENTERPRISE RENT A CAR 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 2:51:22 PM
Creation date
6/24/2019 2:51:07 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
430
Tenant Name
ENTERPRISE RENT A CAR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Exterior Lightin • LTG-EXT <br /> .. 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: ENTERPRISE RENT-A-CAR TI,EVERETT,WA Date 7/9/2017 <br /> Exterior Lighting For Building Department Use <br /> 0 Zone 1 0 Zone 2 @ Zone 3 0 Zone 4 <br /> Zone Table C405.5.2(1) <br /> Specified by jurisdiction. Zone selection required to enable LTG-EXT form <br /> Calculation Area 0 0 Addition-stand 0 Addition <br /> alone +existing <br /> 0 Alteration with<50% 0 Alteration with>—50%ext. <br /> ext.wattage replaced wattage replaced <br /> Building Grounds 0 Efficacy>80 lumens/watt 0 Exemption <br /> Applies to luminaires <br /> >100 Watts 0 Controlled by motion sensor <br /> Tradable Maximum Allowed Lighting Wattage NOTE' Base Site Allowance: 750 1 <br /> Area(ft2),perimeter(If) Allowed Watts Allowed Watts <br /> Tradable Surfaces Surface Description or#of items per ft2 or per If x ft2(or x If) <br /> Main Entry Door 1 30W LF door 30 <br /> Other Entry Door 8 20W/LF door 160 <br /> Total Allowed Tradable+Site Allowance Watts: 940 <br /> Tradable Proposed Lighting Wattage NOTE 2 <br /> Number of Watts per Watts <br /> Tradable Surface Fixture Description NOTE 3,4 Fixtures Fixture NOTE 5 Proposed <br /> Main Entry Door WST P3 Wall Pack:(1)50W LED(6,023 lumens) 1 50 50 <br /> Other Entry Door WST P3 Wall Pack:(1)50W LED(6,023 lumens) 8 50 400 <br /> Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: 450 <br /> watts plus the base site allowance. Any base site allowance not needed to make - <br /> tradable watts comply can be applied to individual non-tradable categories. <br /> Non-Tradable Maximum Allowed Lighting Wattage NOTE' Site Allowance Remaining: 750 <br /> Area(ft2),perimeter(If) Allowed Watts Allowed Watts <br /> Non-Tradable Surfaces Surface Description or#of items per ft2 or per If x ft2(or x If) <br /> Non-Tradable Proposed Lighting Wattage NOTE 2 <br /> Number of Watts per Watts <br /> Non-Tradable Surface Fixture Description NOTE 3,4 Fixtures Fixture NOTE 5 Proposed <br /> Non-tradable proposed watts may not exceed allowed watts for any individual Non-Tradable Watts Exceeding LPA: 0 <br /> surface unless the total excess watts for all non-tradable surfaces are less than the <br /> remaining site allowance. Remaining Site Allowance: 750 <br /> Exterior Lighting COMPLIES WITH MAX. ALLOWANCE <br /> Note 1-List all unique exterior sufaces per Table C405.5.2(2)that occur in the project scope. Select exterior surface categories from drop <br /> down menu. <br /> Note 2-List all proposed lighting fixtures including existing-to-remain fixtures. <br /> Note 3-For proposed Fixture Description,indicate fixture type,lamp type,number of lamps in the fixture,and ballast type(if appicable). <br /> Note 4-Existing-to-remain fixtures shall be included in the Tradable and Non-Tradable Proposed Lighting Wattage tables in the same manner <br /> as new fixtures. Identify as existing in fixture description. \ <br /> Note 5-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For r 1 <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low I / <br /> voltage lighting,enter the wattage of the transformer. Jam(///y <br />