Laserfiche WebLink
Theresa Greene,Architect, PLLC <br /> From: Theresa Greene,Architect, PLLC[tg.architect©comcast.net] <br /> Sent: Monday,April 03,2017 4:22 PM <br /> To: 'Keen,Michelle D';'Koorn,Caleb M' <br /> Subject: Enterprise Everett-OTC Pre-App Meeting Summary <br /> Hi Michelle and Caleb, <br /> Here are the contacts for the departments I met with today at the City of Everett: <br /> Senior Planner:Grace Pollard (gpollard@everettwa.gov) <br /> Building:James Bronder(ibronder@everettwa.gov) <br /> Public Works:Sabrina Fandler(sfandler@everettwa.gov) <br /> The Zoning is C-1. Enterprise Rent-A-Car is a change of use from Auto: Maintenance,Service (Light)to Auto:Sales or Rental. <br /> Auto: Sales or Rental is an approved use with these conditions(condition (d)seems to be the only one applicable): <br /> (49) Permitted only on Broadway, Evergreen Way, Rucker Avenue and a portion of Everett Mall Way with the following <br /> conditions: <br /> (a) The minimum lot area/size would be one hundred eight thousand nine hundred square feet or 2.5 acres for vehicle <br /> sales and related/supportive uses. <br /> (b) Vehicle sales would be allowed on Everett Mall Way from Evergreen Way on the west and First Place West on the <br /> east. <br /> (c) Parking and landscaping standards would be current standards,except an upgrade on the 100th Street frontage where <br /> Type II landscaping would be required. <br /> (d) At least twenty-five percent of the vehicle sales shall be new car sales. <br /> (e) Mitigation measures would be applied to restrict noise including the prohibition of exterior speakers for music and/or <br /> announcements. <br /> Since the valuation for construction is more than 35%of the assessed value of the building,the landscaping curbs may be <br /> required to be adjusted to comply with zoning code setbacks(specifically 10'-0"at the frontage, instead of 5'-0"), unless we can <br /> demonstrate that is not feasible due to min. drive aisle width (which I think we can).We need to submit a Landscape Plan with <br /> our Building permit application indicating required landscape types and plantings as it is not compliance with Zoning code. <br /> http://www.codepublishing.com/WA/Everett/html/Everett19/Everett1935.html#35 <br /> Parking required 1:250 s.f. Office; 1:1000 s.f. Car Wash area (although Grace Pollard was uncertain about the 1:1000 as the use is <br /> not specifically addressed in the zoning code).There is a binding site plan for our property that joins us to the property to the <br /> east, and she printed a schematic utility plan. <br /> Structurally,James Bronder is concerned about the existing infilled floor opening in the future car wash area. Structural will <br /> need to replace or prove that the existing solution is sufficient for the car load, along with providing structural infill designs for <br /> the areas in the customer service area,and header/shear designs to account for the new 12'-0"wide sectional door openings. <br /> The building envelope insulation will need to be prescriptively brought up to code,too. <br /> A detailed site plan is required. If we proposed more than 2,000 s.f. of impervious surface disturbance,we will trigger site <br /> drainage review(Drainage Report). Currently we will be disturbing about 300 s.f. by removing the parking island outside the rear <br /> of the car wash area. <br /> They estimate 6 weeks for review/receive initial comments and there is no intake appointment required.They do not see any <br /> big red-flags for us and recommend we submit for building permit and they will review all of the above at that time (i.e. a Pre- <br /> App is not necessary). Mechanical, Plumbing and Electrical can all be applied as separate permits. <br /> So,we need to get DEI out there ASAP and a Landscape Architect on board...this week is loaded, but I'll contact Edward and see <br /> his schedule and if we can squeeze something in this week or early next. <br /> Theresa Greene,Architect, PLLC <br /> TG I ARCHITECT <br /> 1 <br />