Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing coolinq systems should be used to determine cooling <br /> loads. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> MILLER CUSTOM ALAN-360-422-2392 <br /> 3214 KROMER AVE <br /> EVERETT WA 98201 <br /> Heating System Type: 0 All Other Systems C) Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions Design Temperature Difference(AT) 49 <br /> Everett Paine AFB AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 1,628 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 9.0 14,652 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> U-0.28 .I 0.280 240 67.20 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 — <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> InstructionsR-49 .j 0.026 1,628 42.33 <br /> • <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions No Vaulted Ceilings in this project. <br /> Above Grade Walls(see Figure l) U-Factor X Area UA <br /> Instructions R-21 Intermediate . j 0.056 1,785 99.96 <br /> J <br /> Floors U-Factor X Area UA <br /> Instructions J 0.025 1,056 26.40 <br /> R-38 <br /> Below Grade Walls(see Figure 1)— w _ U-Factor X Area UA <br /> Instructions Select R-value I No selection <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Instructions 0.303 if�l <br /> No Slab Below Grade in this project. . i -- <br /> Slab on Grade(see Figure 11 F-Factor XLeL UA <br /> Instructions _ <br /> No Slab on Grade in this project. •l JI <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> Unconditioned Space . <br /> i 1.10 <br /> Sum of UA 235.89 <br /> Envelope Heat Load 11,559 Btu/Hour <br /> Figure 1. Sum of UAX AT <br /> Air Leakage Heat Load 7,754 Btu/Hour <br /> .,... _...,-..:,,. Volume 0.6X AT X.018 <br /> Above Grade Building Design Heat Load 19,312 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Below Grade Building and Duct Heat Load 21,244 Btu I Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 26,554 Btu/Hour <br /> Building and Duct Heat Loss X 1-40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13) <br />