ROSENBERG RAMBLER I January 24, 2018 SDA Job# 8276 I 6 <br />• WIND <br /> FRONT RWALL SEISMIC <br /> Floor Info Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> Upper Floor Level,e.g.Upper,Main,Lower 1.0 tributary width 1.0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Not Used Not Used <br /> CDX Sheathing type 15.0 tributary width 15.0 tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 51.8 total width 51.8 total area <br /> ROOF Resisting Dead Load Not Used Not Used <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> 8.67 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 1685 lb 1004 lb Height of Shearwall= 7.3 ft Weight of Shearwall= 10.0 lbs <br /> V(from main)= 0 lb 0 lb Length of Shearwall= 3.2 ft Tributary width for dead load= 2.0 ft <br /> V(from lower)= 0 lb 0 lb Aspect Ratio OK Length of adjoining wall= 3.6 ft <br /> E(Wind)= 1,685 lb E(Smc)= 1,004 lb Use alternate R factor for seismic? NO <br /> v= 97 PLF v= 58 PLF <br /> AF&PA SDPWS-2008 1.4 x 0.93 x 230= 299 PLF USE A <br /> Wind controls shearwall design <br /> CTOTAL= (floor above)+(this floor)= + 704 lbs = 704 lbs Wind controls <br /> TTOTAL= (floor above)+(this floor)= + 497 lbs = 497 lbs Load case 8 controls-Wind <br /> , <br /> Wind controls ho(down design <br /> NO HOLDOWNS REQUIRED OK <br /> Where overstrength factor is applicable,use this <br /> value for E in eguations 5,6,and 8: E= 420 lbs <br /> REAR SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> Upper Floor Level,e.g.Upper,Main,Lower 1.0 tributary width 1.0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Not Used Not Used <br /> CDX Sheathing type 6.0 tributary width 6.0 tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 51.8 total width 51.8 total area <br /> ROOF Resisting Dead Load Not Used Not Used <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> 10.50 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 1685 lb 1004 lb Height of Shearwall= 7.3 ft Weight of Shearwall= 10.0 lbs <br /> V(from main)= 0 lb 0 lb Length of Shearwall= 13.5 ft Tributary width for dead load= 2.0 ft <br /> V(from lower). 0 lb 0 lb Aspect Ratio OK Length of adjoining wall= 3.6 ft <br /> E(O.v5)= 1,685 lb E(Eµg)= 1,004 lb Use alternate R factor for seismic? No <br /> v= 80 PLF v= 48 PLF <br /> AF&PA SDPWS-2008 1.4 x 0.93 x 230=299 PLF USE A <br /> Wind controls shearwall design <br /> CTOTAL= (floor above)+(this floor)= + 582 lbs = 582 lbs Wind controls <br /> TTOTAL= (floor above)+(this floor)= + 167 lbs = 167 lbs Load case 8 controls-Wind <br /> Wind controls ho'dawn design <br /> NO HOLDOWNS REQUIRED OK <br /> Where overstrength factor is applicable,use this <br /> value for E in eg-uations 5,6,and 8: E= 347 lbs <br /> LEFT SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> Upper Floor Level,e.g.Upper,Main,Lower 1.0 tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Not Used Not Used <br /> CDX Sheathing type 14.5 tributary width 14.5 tributary area <br /> Values from table 4.3A of the AF&PA SDPWS-2008 51.5 total width 51.5 total area <br /> ROOF Resisting Dead Load Not Used Not Used <br /> (e.g.Roof,Upper Floor,Main Floor) tributary width tributary area <br /> 24.00 ft Total Length of Shearwalls total width total area <br /> V(from upper)= 1461 lb 1004 lb Height of Shearwall= 7.3 ft Weight of Shearwall= 10.0 lbs <br /> V(from main)= 0 lb 0 lb Length of Shearwall= 24.0 ft Tributary width for dead load= 11.0 ft <br /> V(from lower)= 0 lb 0 lb Aspect Ratio OK Length of adjoining wall= 3.6 ft <br /> E(QrvS)= 1,461 lb E(EK)= 1,004 lb Use alternate R factor for seismic? No <br /> v= 30 PLF v= 21 PLF <br /> AF&PA SDPWS-2008 1.4 x 0.93 x 230=299 PLF USE A. <br /> Wind controls shearwall design <br /> CTOTAL= (floor above)+(this floor)= + 221 lbs = 221 lbs Wind controls <br /> TTOTAL= (floor above)+(this floor)= . + -72 lbs = -72 lbs Load case 8 controls-Wind <br /> Wind controls ho/down design <br /> Where overstrength factor is applicable,use this <br /> ry NO HOLDOWNS REQUIRED OK <br /> value for E in eguations 5,6,and 8: E= 152 lbs <br />