Laserfiche WebLink
MiSGS -03g <br /> Johnson Barrow inc <br /> Leaders in Green Solutions Submittal <br /> Date: April 9, 2018 Customer: DK Systems <br /> Project Name: Performing Arts Theatre Engineer: DK Systems <br /> Location: Everett, WA Spec Section: Mechanical <br /> Johnson Barrow respectfully submits the following equipment for review: LJ <br /> Smardt Water Source Chiller AUG 3 0 2018 <br /> CITY OF E\'ERETT <br /> Unit Tag Model Electrical Qty.Permit Services <br /> WSC-1 WB046.1HG07 460 V/ 3 PH 1 <br /> Scope of Supply: <br /> • 460/3 electrical with 65k AIC rating <br /> • Performance: <br /> o 0.552 kW/ton IPLV rating <br /> o Evaporator: 358.4 gpm 54F/44F water <br /> o Condenser: 448.6 gpm 85F/95F water <br /> • 2-Danfoss Turbocor OIL FREE, magnetic bearing, variable speed centrifugal compressors <br /> • Compressor suction and discharge isolation valves <br /> • Step-less capacity control using inlet guide vanes and internal variable speed drive <br /> • Flanged vessel connections <br /> • 145 PSI standard water boxes <br /> • HFC 134a refrigerant <br /> • Cleanable flooded evaporator providing low temperature approach and built to ASME standard <br /> • Water cooled cleanable shell and tube condenser built to ASME standard <br /> • High resolution electronic expansion valve <br /> • 3/4" (19mm) closed-cell insulation to prevent external condensation <br /> • Advanced Control System including integrated communication with compressor for precise capacity <br /> • control and operational safeties <br /> • 12" color graphical interface with panel mounted touch-screen <br /> • BACnet MS/TP communication interface <br /> • Single point electrical entry <br /> • 12/18 month standard parts and labor warranty <br /> • R-134a - refrigerant ships loose for field charging by others <br /> • Partial knock-down construction: Removal of compressors and electrical panel to facilitate <br /> moving equipment into the mechanical room. <br /> • Factory certified startup <br /> Exclude: Spring isolation, valves, refrigerant monitoring/alarming, refrigerant vent piping, disconnect, <br /> signal conditioning, installation, rigging, setting, storage or other options not listed above. <br /> Note: Signed and Dated approval for release of equipment required. <br /> Submitted By: <br /> Blake Bledsoe <br /> Johnson Safi Sow W;ishm for <br /> _ <br /> t �!)5-C <br /> . „1`:1_ <br /> Emilr_Onl <br /> 2203 23rd Avenue S Seattle , WA 98144 <br /> PHONE (206) 284-1476 <br />