Laserfiche WebLink
A PORTION OF THE NW 1 /4 OF THE NE 1/4 OF SECTION 7, T 28 N, R 5 E, WM <br /> � <br /> J <br /> � i � <br /> � ��; �6 I � <br /> LOT 2 � ' 3 � � LOT 12 0 � <br /> � . i � o <br /> I � � TW=485.00 TW=479.47 � <br /> � � TW=481.50 W=�1.� BW=473.97 z <br /> ( BW=481.0 - • I � � Q <br /> ;� � 3 � - � LOT 3 z � o Q <br /> I � � $ _ � � � <br /> - - ( � � � � 4 NORTH � � w <br /> G . ^ <br /> r <br /> ( I o -4 . WA�ETAIWING I Z � Z W <br /> � � 0 10 20 40 Q O W <br /> � i' 3�� 471 �1'L � ; TW= 488.81 " , <br /> SCALE: 1 =20 � <br /> � . . BW=482.81 Q � � � <br /> I � 18. ' B C 5 SW TW=47g,46 �' � Q W <br /> ( �� � oW P 366 �N�T Ac �N�T B � 3 � 85 47796 _ GRADING C4NSTRUCTI(JN NOTES � � <br /> LOT 3 I ' - <br /> FF=472.0 FF=472.0 UNIT C UNIT D z <br /> P � 47i.9 / I P 472.. FF=473.5 FF=473.5 ' Q <br /> ( . 7 � P 471.69 _ _ W <br /> ' . ( � P 473.17 � 4 � � 1� INSTALL 20' WIDE DRIVE PER DETAIL ON THIS SHEET. (' <br /> � 4 � <br /> -------- -- ------_---- --- � <br /> ---� -s----- ------_---- --� - P 473.50 z <br /> I _� p . �.__� .,.�_ ____..�.___.�._._,_.v_.._�,....____�.._.___. .�__�.__..�..�.... �._. .� _. ,.�.._._. ..CP"�7i:'�., .u.__.___�.w...__._ _dp�____w^�~ i_`" .._. _W..P 473.48 s'x5 TRASH ENCLOSURE �2 WSTALL MAILBOX CLUSTER PER DETAIL ON THIS SHEET. � <br /> I i GB 471.78 � 472.63 � � 472.97 P 473.43 <br /> .1 PER DETAIL THIS SHEET <br /> 'd' � -1.OX N 471.36 � � � 473.18-� � Q <br /> P � -8.8X � � � -4 8$ -�•0� ���y 4� � � 3� INSTALL "NO PARKiNG - FIRE LANE" SIGN PER DETAIL ON THIS SHEET. � <br /> � 1 7 0� f� 47�,4g ,�N g P 473.43 <br /> � P 9.88 �' 471.36 �* P 473.48 ,�, � <br /> � ___-_-_---__- -- __-- -___. _-_ � ___ _____-____ �_ Tw=fe+e-487.72 �4 INSTALL TYPE I DRIVEWAY PER COE STD 315. <br /> -- -._._ __--___ <br /> � ( � 3 P 471.69 p 472,8 P 473.18 � � - • �� P 4W_���, 72 LOT 4 5 INSTALL CONCRETE WALL AND FOOTING PER BUILDING PLAN SET <br /> � � UNIT H UNIT G �� , , UNIT F UNIT E . . TW=479.45 <br /> P 470�� FF-472.0 FF-472.0 FF-473.5 FF-473.5 3 g�473.95 PREPARED BY IMPRESSION DESIGN. <br /> �� � � �.Y�t .. � <br /> K� P 471.98 3 ' 4l2 � <br /> I - �'s � � 4j4 ��6 ��a � � SEE SHEET C7 FOR RAINIER DRIVE IMPROVEMENT PLANS. <br /> 6 2 4�2 C�T 11 ��° <br /> � . . <br /> , � , <br /> � ! � ; �7 INSTALL ORNAMENTAL HANDRAIL PER COE STD 334. <br /> � , ,�_....� TW=479.43 �" <br /> W � BW=473.93 '�.« <br /> � � �-- � 7w-q�e.4gg.26 �8 INSTALL 6' SOLID WOOD FENCE. �' "`-- <br /> � � <br /> _� I EX. RETAIINING .�.��0.3 Tyy=483. � BW--�}fr3-480.26 �``�.� <br /> � � I `` �: � I ( ( wA�- aw=47s.8 W=479.8 - 9 4" iMDE PAINT STRIPE FOR WALKWAY. `''� ��'Qr� <,� ��v'y <br /> LOT 4 � 3 � � H � � I F ( E 4 . � o~'.�' �, o'�ti <br /> I ( ( L � L _4 J _4 : �''���� - � 10 INSTALL CONCRETE BLOCK WALL (MAX. 4' HEIGHT) '��-'�� `�,- `- ��```� <br /> � � LEX. CONDOMIN1M BUILDING J �X. CONDOMINI JM BUILDING ��`� <br /> � � � � � a <br /> I � � I � ❑' , ' N 1 O <br /> � � ��� <br /> ( Z ; I EX. RAINIER LANDING CONDOMINIUM Tyy-47g,4� -� � <br /> BW=473.91 � r $ Q4��� <br /> I Q ` � LOT 10 ���' <br /> , <br /> � � ' LOT 5 4 �, <br /> � �� I ,WALK � <br /> _ 23'-' __ 1-0'- _... _ 10' _ ' <br /> � � I _ --- --,-- 2.3_' <br /> ; <br /> ' , 1� i <br /> ���'� � 4" WIDE-,, � � , <br /> FACE OF ��� " � � PAINT � �' ���-- FACE OF <br /> BUILDING ' � � STRIPE � <br /> , ; �� I ' BUILDWG <br /> 1�i 2% ' _2% '' ' 1% �! <br /> NOTES <br /> NO PARKING SIGN NOTES � <br /> Z N <br /> a� <br /> , �. = � <br /> 1. THIS DRAWING DEPICTS A MINIMUM 1. SIGNS SHALL READ "NO PARKING - FIRE LANE - TOW AWAY ZONE - 2" MIN. COMPACTED DEPTH HMA CLASS 1/2" PG 64-22 --- N N � N � <br /> STRUCTURAL AND DIMENSIONAL STANDARD FOR E M C 4 6.2 8.1 3 0". 4" MIN. COMPACTED DEPTH CRUSHED SURFACING BASE COURSE-- Z W � rn � <br /> 4' M W - NEIGHBORHOOD DELIVERY&COLLECTION BOX Q �"' . � <br /> UNIT{NDCBU}AND PADS FOR SPECIFIC POSTAL „ � SUBGRADE COMPACTED AS RECOMMENDED BY GEOTECHNICAL ENGINEER � Q p � � <br /> REQUIREMENTS CONTACT THE POSTMASTER. 2• SIGNS SHALL BE TWELVE INCHES (12 � IN WIDTH, EIGNTEEN INCHES (18 ) W � 3 c N <br /> � 2' MIN CLEAR � L �n <br /> IN HEIGHT, WITH RED LETTERS ON A WHITE BACKGROUND. V � � � <br /> � . . 2. MAILBOXES MUST BE POSTMASTER APPROVED � � <br /> CONCRETE PAD - ' • . PATRON ACCESS SIDE WITH A UNIFORM BOX STYLE AND METHOD OF 3. THE LETTERS INDICATION "NO PARKING" AND "FIRE LANE" SHALL BE NO P R I V A T E D R I V E S E C T I O N � � � � � <br /> ' . � P O S T A L A C C E S S S I D E ADDRESS IDENTIFICATION. <br /> ' e � 2' MIN CLEAR LESS THAN TWO INCHES (2") IN HEIGHT. THE LETTERS INDICATING 'TOW NOT TO SCALE a N � > a- <br /> . . . r-� i <br /> NDCBU BOX -�-' � J � ----- AWAY ZONE" SHALL BE NO LESS THAT ONE INCH (1") IN HEIGHT. "EMC 0 a � w <br /> _ a . . , <br /> , <br /> . . � �� RECORD �RA'�'� � � O <br /> � . ' ° ; ;; 3. LOCATIONS OF MAILBOXES ARE SUBJECT TO „ „ � <br /> o w • . �---------�� 46.28.130 SHALL BE NO LESS THAN 3 4 IN HEIGHT. � � <br /> w w " ,.�' • _ • � ..a I I� APPROVAL BY THE CITY ENGINEER FOR � Z <br /> , �-------„ Q <br /> � t� �---------�� B A S E P L A T E A N D B O L T PROTECTION OF VIEWS AND ACCESS. This Record Drawin g h�s be e n p r e p a r e d, i n p a r t, b a s e d a � <br /> � z � � �„ 4. SIGNS SHALL BE INSTALLED SO THAT THE TOP OF THE SIGN IS NO MORE on"As-Built" inr, ��„��;or� provided by others.Though <br /> w w w w r, � PATTERN PER NDCBU the as-built �n,+ormation and this drawir. <br /> � x � a �,,, SEE NOTE 5 4. INSTALLATION OF DRAINAGE CULVERT MAY BE THAN SIX FEET (6') ABOVE PARKING GRADE LEVEL AND THE BOTTOM OF g are based on � <br /> w Q O Y MANUFACTURER , <br /> o � z � c� NECESSARY IN AREAS WHERE THERE IS NO � the best ava� �b�e information, no presumption should <br /> �, � THE SIGN NO LESS THAN FOUR FEET (4 ) ABOVE THE PARKING GRADE <br /> '�' �. o W Q � CONCRETE SIDEWALK AND THE REQUIRED be made regar ing the drawing's accuracy. 5' <br /> �, Q m N N � o SEE STD DWG 312 - P�i LEVEL. <br /> 3 w o 1 7,� SETBACK SPANS A ROADSIDE DITCH.ACCESS TO � �'\ ` -- <br /> � � v~i � �'� SUCH STRUCTURES WILL HAVE A MAX. SLOPE OF '�" � � �"�� REVISIONS: APPD. <br /> o - . �• ._ a ' , -' � ••� : . , ?S1 2%AND SHAI.I HAVE A PAD CONSISTING OF A 5. LOCATIONS OF SIGNS SHALL BE BY APPROVAL OF THE FIRE MARSHAL OR Signed By Date <br /> � � " • -- • • �M MINIMUM OF 2" OF CRUSHED SURFACING TOP HIS DESIGNEE. PAINT CURBS RED WITH WHITE LETTERS STATING "NO , <br /> } • -•- - -+- - - �"-- -s-� =< . - q,�- c... \�1� 1(,:��� Permit Inspector <br /> � EDGE OF • � COURSE COMPACTED TO 95% MAXiMUM PARKING - FIRE LANE". Print Name &Ti? <br /> o TRAVELED WAY #4 @ 14" EW DENSITY. <br /> m CURB&GUTTER � -6' TALL SOLID WOOD <br /> 5. ALL MAILBOX STRUCTURES SHALL BE PLACED FENCE AND SOLID WOOD <br /> a S E T B A C K P L A N S I D E E L E V A T I O N W I T H S I D E I NA LK B A C K O F S I D E W A L K W I T H N O P O R T I O N O F B O X 12�� <br /> � OR STRUCTURE PROTRUDING INTO THE � GATES. <br /> SIDEWALK. IF NO SIDEWALK EXISTS SETBACK WILL <br /> :`Letters Mi"rvua <br /> � BE SET BY THE CITY ENGINEER. <br /> in �� � <br /> W6. SUGGESTED SOURCE SECURITY MANUFACTURING ���,��,„,,,, � <br /> o CORPORATION (800) 762-6937, 8000 SERIES � <br /> PARKING <br /> � PEDESTAL BOXES, SALSBURY INDUSTRIES (800) DATE• JANUARY, 2018 <br /> � 323-3003 OR POSTAL APPROVED EQUAL. 18 � <br /> ;. <br /> ,, <br /> `-`�""'°"`"'"' ' DESIGN: BJN <br /> � FIRE LARIE � <br /> o POSTAL ACCESS SIDE � PATRON ACCESS SIDE 7. PLACEMENT LOCATION OF PEDESTAL PARCEL SURFACE TO BE ASPHALT -- � DRAWN: CD <br /> o LOCKER WILL BE APPROVED BY THE CITY PAVEMENT PER PRIVATE QRIVE CHECKED: JNS <br /> Y �, , , � ENGINEER AND THE POSTAL SERVICE. ,^L�pr M�n�, SECTION DETAIL THIS SHEET <br /> } o 0 0 0 ,' REVISION <br /> w ;; TOW AWAY ZONE NUMBER: <br /> � � � � ° � �; TRASH ENCLOSURE <br /> �� - BASE PLATE AND BOLT �"Letters Minimum n � <br /> �a � � � � �---------�� EMC 46.28.13U NOT TO SCALE SCALE: 1 =20 <br /> o� -�--- SEE NOTE 5 I PATTERN PER NDCBU <br /> nr;i MANUFACTURER <br /> �� NDCBU =31" MIN CLASS 3000 PROJECT NUMBER: <br /> �E� PARCEL BOX=20" MIN CONCRETE PAD SEE NOTE 4 - p.� <br /> o� � + � 1,� � REYK-0004 <br /> mm ° �. �. ` a '; ° 12" MIN � ' • �- ` • °� '.� • � ?�M DRA�PING FILE: <br /> �� �'- - - � '- ' - � 1 - - �'� - Ec-AB-410-REYK0004.dwg <br /> �n n ��� �� �� � <br /> M� #4 @ 14�� EW 1,2 X 6 x 1-1/2 �- CITY �F EVERETT <br /> �� ANCHOR BOLTS EVERETl R E CO R D D RAW I N G CALL SHEET N0. <br /> �'°' FRONT ELEVATION SIDE ELEVATION WITH OUT SIDEWALK �� PUBLIC WORKS DEPARTMENT 2 BUSINESS DAYS <br /> 00 <br /> N N Cit���Er�gi�er Se[�ionManager CADManage� D�awnBy Cune�RevD� 6 19 2019 BEFORE YOU DIG <br /> �p� RYAN SASS TOM HOOD PAUL WILHELM ESH 04 26 2017 <br /> �e- nnE <br /> �� S1�NU�PDDMWINGNo • FOR UTILITY LOCATE <br /> 811 <br /> Qo NDCBU MAILBOX CLUSTER 329 oF 9 <br /> o > <br /> _ � <br /> a cn <br />