My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD VOL 2 OF 8 2014 BLDG 40-58 Plans 2022-11-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD VOL 2 OF 8 2014 BLDG 40-58 Plans 2022-11-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 9:58:17 AM
Creation date
7/3/2019 10:23:17 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Unit
VOL 2 OF 8
Tenant Name
BLDG 40-58
Permit
B1410-016
Year
2014
Notes
777X CWC BLDG VOL 2 OF 8
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
276
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> SOILS CQNST�UCT1�1� �IBC 17�5.�}: i�ASTIC AND I�ITUMESCEf�T �IRE RESI�TANT Ct�ATI�IGS �IBC 1705.14): � <br /> ITEM FREQUENCY�F INSPECTIC}N INSTRUCTIONS ITEM FREQUENCY OF INSPECTI4N I�JSTRUCTIONS � <br /> � <br /> �— <br /> VERIFY SUBGRADE IS ADEQUATE TO CONTI�JU4US � PERIUDIC ❑ PRIOR TO PLAGEMENT OF CONCRETE. SURFACE PREPARAT141� CQNTINUOUS ❑ PERIODIC ❑ PRIOR Ta APPLICATIQN CC}NFIRM THAT SURFACE � <br /> ACHIEVE DESIGN BEARING CAPACITY TEMPERATURE AND SUBSTRATE ARE '�'�- <br /> ACCEPT'ABLE AI�D THAT A COMPA�'IBLE PRI(�ER IS � <br /> �SED IN ACC4f�DANCE WI7'N AWCI 12-8 � . <br /> VERIFY EXCAVATIONS EXTEND TO GONTINUC}US ❑ PEI�iODI� � PRIQR TO PI.ACEMENT OF COMPACTED FILL � <br /> PROPER DEPTH AND MATERIAL OR CONCRETE. � <br /> TNICI�NESS CGNTIN�JflUS ❑ PERIQDiG ❑ RE�ORD THICKNESS OF PRIMER t�R OTHER � <br /> VERIFY THAT SUBGRADE HAS BEEN CONTINUOUS � PERIO�IC ❑ PRIOR TO PLf10EMENT 4F COMPACTED FIL�.. EXISTING COATING (3N SUBSTRATE PRInR TC? W <br /> APPROPRIATELY PREPARED PRI�R TO APPLICA710N OF COA`�IN�. FINAL TNICKNESS OF � <br /> PLACING COMPACTED FILL GOATING MUST BE VERIFIED IN MULTIPL� CJ�? <br /> LOCA714NS P�IOR TC?APPLYING TOP COAT PER CI�� <br /> PERFORM CLASSIFICATION AND CONTINUC}US � PERIQDIC ❑ ALL MATERIALS SHALL BE CHEGKE�AT ��G� ��"B� <br /> TESTING OF COMPACTED FILL EACH LIFT FOR PRtJPER CLASSIFICATIC}NS ,����ITECTU�AL �{�MPC1N ENTS I B� 1 TU�.� � .� CX � ���. � � .7 . <br /> MATERIALS AND GRADATIUNS NQT LESS THAN 41UCE � � <br /> FOR EACH 10,OOf}FT 2�QF SUR�ACE AR�A. <br /> ITEM FREQUENCY OF INSPEGTION INSTRU�TIQNS <br /> VERIFY PROPER MATERIALS, CONTINU4US � PERIODIC ❑ <br /> DENSITIES AND LIFT THICKNESSES ER�CTIdN AND FASTEIVII�G 0� CONTINIJOUS ❑ PERIODIC � VERIFY APPR�IFRIATE MATERIALS, FASTENERS AND <br /> DURING PLACEMENT AND EXTERIQR CLADDING OR INTERI�R ATTACHMENT AT COMMENCEMENT OF WQRK AND <br /> COMPACTION AND EXTERI�R VENEER� AT GC�MPLETI4N. PERFORMED BY CQDE INS�'ECTIQN <br /> FIRM. (N(�T REQUIRED IF' < 30 FEET{7R LESS THAN <br /> 5PSF}. <br /> ER�CTIQN AND FASTENINC� �}F CUNTINUtJUS ❑ PERIODIG � V'ERIFY�PPR�PRIATE MATERIALS, FASTENERS . <br /> CAST'IN-PLAC� ���P FC�U���TIC}NS �IBC � ��5.��. INTERIORAN[� EXTERIOR ANDATTACHMENTATCOMMENCEMENTOFW{�RK <br /> N4NBEARING INALLS AND A7 C4MPLETION. PERFORMED BY CC}DE <br /> INS�PECTION FIRM. (NiJT REQl71RED IF < 30 �EET <br /> ITEM FREQUENCY ClF INSPEC7IQN INSTRUGTIQNS QR FOR INTERIC}R WA�.LS < 15PSF}. <br /> OBSERVE DRILLING OPERATION CC7IVTINUOUS � PERIODIC ❑ �TQRAGE RACKS CONTINUOUS ❑ PERIODIC ❑ V�RIFY THAT ANCHOF�AG��OMPLIES WITH <br /> AND REPORTING APPRflVED CONSTRUC710N DOCUMENTS. <br /> INSP�CTION QF POST-INSTALLED ANCHORS SHALI. <br /> CfJMPLY WITH APPROVED ICGES REPORT. <br /> VERIFY PLACEMENT LOCATIONS& CpNTI�IUQIJS � PERI�3DIC ❑ PERFORMED BY CODE lNSPECTt�N FIRM. <br /> PLUMBNESS, CONFIRM ELEME�IT <br /> DIAMETERS, LENGTHS, EMBEDMENT � <br /> ANDADEQUATEEND-BEARWG MECHANICa� & ELE�TRICAL C�JMPONENT� �IB� 91U�.� � .� Ot 17��. � � .V}. <br /> CAPACITY. RECORD CONCRETE <br /> VOLUMES <br /> ITEM �REQU�NCY C}F IM1ISPECTION INSTRUCTI4NS <br /> PERFORM ADDITIONAL INSPEC7I�NS CU�lTINU�JUS � PERIODIC ❑ CONCF�ETE PER IBC 1705.3. <br /> FOR REINFORCING STEEL ANCHCIRAGE OF EMERGEIVCY OR CCINTINUaUS ❑ PERIODIC � VERIFY THAT ANCHQRAGE C4MPLIES WITH <br /> STANDBY POWER SYST'�MS APPROVED CC}NSTRUCTION DOCUMENTS. <br /> PERFORMED �Y C4DE 11VSPECT101V F1RM. <br /> SPRAYED FIRE-RESISTANT MATERIALS �IBC � �U5. � 3}: � <br /> INSTALLATIQ�J C3F PIPING SY�TEMS �ONTINUOUS � PERI�DIC ❑ V�RIFY THAT INSTALLA�ION AND RESISTANT <br /> ITEM FREQUENCY OF INSPECTIQN INSTRIJCTIONS CARRYING FLA(�MABLE, COM�LY WITH APPROVED CONSTRUCTION <br /> CaMBUSTIBLE OR HIGHLY TOXIC DCICUMENTS. PERFORMEt7 BY CODE!IV�PECTIQN <br /> MATERIALS FfRM. <br /> SURFACE PREPARATI4N CONTINUQUS ❑ PERIUDIC ❑ PRIC}R TO APPLICATiC1N GQNFIRM <br /> THAT SURFACE HAS BEEN <br /> PREPARED PER THE APPROVE� INSTALLATIC}N OF HVAC DiJCTV�'ORK CONTIN�J�US ❑ PERIQDIC ❑ VERIFY THAT INSTALLATI(?N AhJQ RESI�TANT <br /> FIRE-RESISTANCE DESIGN AND CQNTAINING HA�ARD�JUS C(JMPLY t111lTH APPROVED CC?NSTRUCTI�N <br /> MANU�ACTURER'S INSTRUCTl�}NS. MATERIALS DC�CUMEN7S. PERF4RMED BY CaDE iNSPECTIC3N <br /> FlR1Vt. <br /> MATERIAL THICKNESS CONTINUC}US ❑ PERIODIC ❑ SAMPLES SHALL �E TAKEN FE��JM <br /> aELECTED FL44R, R�C�F ANI�WALL <br /> ASSEMBLIES AND STRUCTUi�AI� INSTALLATION QF VIBRATI4N CONTINUQUS � PERIQDIC ❑ VERIFY THAT INSTALLATION G�MPLIES WITH <br /> MEMBERS, Na MORE TNAN �0% OF IS4LATIQN SYSTEMS HAVING A APPROVED CONSTRUCTION DC}CtlMENTS AND <br /> THE SAMPLES SHALL BE LESS THAN CLEARAIVCE �F< 1/4". MANU�A�TURERS RECOMMENDATI(}NS. <br /> TNE THICKNESS REQUIRED BY THE � PER�QRMED BY CODE tNSPECTION FlRM. <br /> FIRE RESISTANCE DESIGN. <br /> MATERIAL DENSITY CONTINUOUS ❑ P€RIODIC ❑ DENSITY TESTS SHALL BE PEF�FORMED IN DESIGNATED �EISMIC SYSTEMS C{3NTINUOUS � PERIODIC ❑ CONFIRM THAT MANUFACTURERS CERTIFICATI4�1 <br /> AGCORDANGE WITH AS7M E605 FOR EVERY OF COMP�IA�lCE CtJNFt?RN1S TO THE <br /> 2,500 FTZOF FLOOR, RQO� QR WALL AREA. REQUIREMENTS OF SECTIC�N 13.2 QF ASCE 7-10. � <br /> 4NE SAM�LE MUST ALSO 8E PRdVID�D �OR VERIFY THAT TF1E LABEL, ANCHORAGE OR <br /> EACH BE�M, GIRLER,TRUSS aR COLUMN AT MOUN7ING CONFORMS TO THE MANUFAGTURER'S <br /> EAC�fi ST4RY. CE�2TIFICA`�I�N OF COMPLIANCE. f'ERFORII�E�BY <br /> CQDE INSPECTIaIU FIRM. <br /> � BONDING STRENGTH �4NTINUC}US ❑ PERIODIC ❑ BOND STRENGTH TESTS SFIALL BE PERFORMED �PECIAL CASES {I BC 17"��. 1 .� �-MA�TERIAL ALTEF�NATIVES QR UNU�UAL <br /> IN ACCQRDA�ICE WITH ASTM E736 FOR EVERY <br /> 2,5�OFT�4F F�OQI�, ROOF aR WALLAREA. {�NE DE�i�N APPLI�ATI(�NS. <br /> SAMPLE MUST ALS� BE PROVIDED FOR EACH BEAM, <br /> GIRDER, TRUSS OR CaLUMN AT EACH STC?RY. 7HE <br /> BQ�1D STRENGTH SHALL N�T �E LESS THAN 150PSF. ITEM FREQUEMCY QF INSPECTIC}N . INSTRUCTIt�NS � <br /> MATERIAL i AND INSTALL�TIC7N CflNTINUOUS � PERIODIG ❑ PER DE�IGN PROFESSIONAL (N RESPQNSIBLE <br /> CHARGE OR F�EPORT FROM AN AGCEPTED <br /> P►CCREDITATION AGENCY(LE. ICC-ES). <br /> , �,�ut. 8q�� <br /> ����dF w a�y�y`�� <br /> � �� ,��a <br /> � � ���� . <br /> 26: P 1 -07- �' �C 1T) <br /> w <br /> �a�j 81 4�����"���- <br /> ��s�NA L �-���� a <br /> 9�� ��+t � b�h �tr��� �+u��� ��?� �, <br /> �.�'CI'�£�!�� W�'��1���:{�� ����� David P. Balawajder +�-� <br /> : WA P� 28184 0 <br /> SYM REV1SIOh[ BY APPROVEE3 DATE SYM REVISIi?N �' ,qpp�py�Q Qq� ORAWN OATE SUBTITLE CURRENT REVISIQN SYMBOL DATE o <br /> oF �;A��,� ACCEPTABILITY MEM 1Q 09 14 �, <br /> EM AHM 10 09 14 �P�� "�'ro THIS DESIGN AND/OR C - KED �TATEMENT C�F SPECIA� INSPEGTIGINS w2�4�3�� a �Q/o�/� 4 � <br /> 0 ISSUE FOR CONSTRUCTION M / i y � SPECIFlCATION IS APPROVE� �H� 10 09 14 SHEEf � <br /> ������ � �,��+�ECzs � � TITLE BOEING 777X CW� BUILDING '�'` <br /> ENGINEERSINC. APPROVED �Y t7EPT. DATE DP� 1 Q 09 1�} �� r- <br /> yq 3��� CHECKED � <br /> �fF��._...v_.�..._�_�_,_. �o APPROVE(1 B�U I L D I N G 40��V V �OB No. GOMP N0. Y <br /> `''T��F �uT���`�`� APP�QVED STRUCTURAL MASTER EVERETf, WA pw� ��� 40—a58—S2f � <br />