Laserfiche WebLink
BY VALMONT INDUSTRIES FOR: GENERAL DYNAMICS 113.1667' POLE, SITE: WA6348 - GLENWOOD DATE 11/11/2016 <br /> Fuse 1.13.0.0 <br /> *** INPUT LOADS *** <br /> Design Code TIA-222-G Addendum 2 <br /> Loading Case ICE + WIND <br /> Orientation of System <br /> Basic Wind Velocity is 40.00 mph Ice Thickness 0.25 +******* +X-Axis <br /> Wind Orientation is 50.0 Degrees Clockwise From +X Axis * * (Transverse) <br /> Structure Weight Overload Factor is 1.200 * * <br /> Exposure C, Gust Factor 1.10 * * <br /> Structure Category 2, Topographic Category 1, Crest Height 0.00 ft (Longitudinal) * * (Vertical) <br /> Orientations are Measured Clockwise From +X Axis +Y-Axis * * +Z-Axis <br /> Positive Y Axis is 90 Degrees Clockwise From +X Axis <br /> Foundation Rotation of 0.00 Degrees <br /> Elevation of structure base above surrounding terrain = 1.00 ft <br /> Load Mounting Load Load Orientation <br /> Number Height Height Eccentricity in XY Plane Force-X Force-Y Force-Z EPA <br /> (ft) (ft) (ft) (Degrees) (lbs) (lbs) (lbs) (ft"2) <br /> 1 104.00 104.00 0.00 50.00 109 130 554 31.11 3-SBJAH4-1D65 <br /> 2 92.70 92.70 0.00 50.00 292 348 1404 85.02 6-OCT458KBU00 <br /> 3 112.17 112.17 0.00 50.00 3 3 22 0.70 1-4ft lightni <br /> 4 104.00 104.00 0.00 50.00 86 102 508 24.39 3-SBNHH-1D65B <br /> 5 104.00 104.00 0.00 50.00 14 17 122 3.96 6-Andrew E15Z <br /> 6 104.00 104.00 0.00 50.00 7 8 86 1.92 3-Andrew E15S <br /> 7 104.00 104.00 0.00 50.00 20 24 256 5.67 3-Alcatel-Luc <br /> 8 104.00 104.00 0.00 50.00 19 23 284 5.52 3-Alcatel-Luc <br /> 9 104.00 104.00 0.00 50.00 22 27 569 6.33 3-T-arm SP1 1 <br /> 10 92.70 92.70 0.00 50.00 124 148 1699 36.24 12-RRUS12 [20. <br /> 11 92.70 92.70 0.00 50.00 31 37 248 9.06 3-Raycap RCMD <br /> 12 92.70 92.70 0.00 50.00 22 26 569 6.30 3-T-arm SP1 1 <br />