Technical Data Sheet(Continued) <br /> Presidential Shingles Po c 2-of 3' <br /> Technical Data: Presidential Shake Presidential Shake TL <br /> Weight/Square (approx.): 355 lb. 475 lb. <br /> Dimensions(overall): 14 1/4"x 40" 14 1/4"x 40" <br /> Shingles/Square: 90 90 <br /> Weather Exposure: 4" 4" <br /> INSTALLATION <br /> The following is a general summary of the installation methods. Detailed installation instructions are <br /> supplied on each bundle of Presidential Shake TL and Presidential Shake shingles and must be followed. <br /> Separate application sheets may also be obtained from CertainTeed. <br /> IMPORTANT NOTE- Presidential Starter or an approved alternative starter system must be used for the <br /> two-layered starter course. <br /> Roof Deck Requirements: Apply shingles to minimum 3/8"thick plywood, minimum 7/16"thick non- <br /> veneer, or minimum 1"thick(nominal)wood decks. The plywood or non-veneer decks must comply with <br /> the specifications of APA—The Engineered Wood Association. <br /> Ventilation: Provisions for ventilation should meet or exceed current HUD Standards. To ensure <br /> adequate balance ventilation, use a combination of continuous ridge ventilation (using CertainTeed Ridge <br /> Vent products, or a comparable product with an external baffle)combined with soffit venting. <br /> Valleys: Open valley is recommended.Valley liner must be applied before shingles. It must be minimum <br /> 18"wide 16 oz. copper, or its equivalent, installed over 36"wide self-adhering CertainTeed WinterGuard <br /> Waterproofing Shingle Underlayment(apply directly to deck), or applied over 36"wide mineral surfaced <br /> roll roofing. After WinterGuard has been applied, install the 16-oz. copper centered in the valley. For <br /> application of copper valley, use copper cleats or large head copper nails. Closed-Cut valley application <br /> is an acceptable alternate, provided the shingles are not damaged while being formed into place. Refer to <br /> the application instructions on the shingle packaging for further information. <br /> Underlayment: <br /> On slopes 4" per foot or greater, CertainTeed recommends one layer of DiamondDeck® Synthetic <br /> Underlayment, or Roofers'Select High-Performance shingle underlayment, or shingle underlayment <br /> meeting ASTM D226, D4869 or ASTM D6757.Always ensure sufficient deck ventilation, and take <br /> particular care when DiamondDeck or other synthetic underlayment is installed. For UL fire rating, <br /> underlayment may be required. Corrosion-resistant drip edge is recommended and should be placed over <br /> the underlayment at the rake and beneath the underlayment at the eaves. Follow manufacturer's <br /> application instructions. <br /> On low slopes (2" up to 4" per foot), one layer of CertainTeed's WinterGuard Waterproofing Shingle <br /> Underlayment(or equivalent meeting ASTM D1970)or two layers of 36"wide felt shingle underlayment <br /> (Roofers' Select High-Performance Underlayment or product meeting ASTM D226, D4869 or ASTM <br /> D6757)lapped 19"must be applied over the entire roof, ensure sufficient deck ventilation. When <br /> DiamondDeck or other synthetic underlayment is installed,weather-lap at least 20"and ensure sufficient <br /> deck ventilation. When WinterGuard is applied to the rake area,the drip edge may be installed under or <br /> over WinterGuard. At the eave, when WinterGuard does not overlap the gutter or fascia, the drip edge <br /> should be installed under WinterGuard. When WinterGuard overlaps the fascia or gutter, the drip edge or <br /> other metal must be installed over it. Follow manufacturer's application instructions. <br />