My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 MERRILL CREEK PKY T MOBILE ANTENNA 2019-07-08
>
Address Records
>
MERRILL CREEK PKY
>
2215
>
T MOBILE ANTENNA
>
2215 MERRILL CREEK PKY T MOBILE ANTENNA 2019-07-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2019 10:51:58 AM
Creation date
7/8/2019 10:51:55 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2215
Tenant Name
T MOBILE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES: ABBREVIATIONS: <br /> 1. THE PROPOSED INSTALLATION WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR <br /> SEWER SERVICE. AFF ABOVE FINISHED FLOOR JT JOINT <br /> AFG ABOVE FINISHED GRADE LAM LAMINATED <br /> 2. THE PROPOSED INSTALLATION IS UNMANNED AND IS NOT FOR HUMAN HABITATION(NO HANDICAP AFS ABOVE FINISHED SLAB LF LINEAL FOOT <br /> ACCESS IS REQUIRED) ALUM ALUMINUM MANUF MANUFACTURER <br /> AB ANCHOR BOLT MAX MAXIMUM IL <br /> 3. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION,APPROXIMATELY 2 TIMES PER L ANGLE MECH MECHANICAL 0 tY <br /> MONTH,BY T-MOBILE TECHNICIANS. ARCH ARCHITECTURAL MH MANHOLE a yy>`j o <br /> BTS BASE TRANSMISSION SYSTEM MM MILLIMETER n' fl <br /> 4. NO NOISE,SMOKE,DUST OR ODOR WILL RESULT FROM THIS PROPOSAL. BLDG BUILDING MIN MINIMUM �Wo� >s ? <br /> BM BEAM MISC MISCELLANEOUS <br /> 5. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED. BOT BOTTOM MPH MILES PER HOUR �� VD <br /> B.O. BOTTOM OF MTL METAL /AMS <br /> 6. ALL REFERENCES TO SPECIFIC STANDARDS FOR THIS PROPOSAL ARE UNDERSTOOD TO BE THE LATEST BOC BOTTOM OF CONCRETE NIC NOT IN CONTRACT .,•S_J` <br /> VERSION. BOS BOTTOM OF STEEL NOM NOMINAL <br /> CJ CONTROL JOINT NTS NOT TO SCALE <br /> 7. THE TENDERED MUST UNDERGO A SITE VISIT TO CAREFULLY EXAMINE AND UNDERSTAND THE SCOPE OF i CENTER LINE OC ON CENTER ' ��� <br /> THE WORK REQUIRED BEFORE BID SUBMISSION.NO COMPENSATION IN ANY FORM WILL BE PAID FOR CLG CEILING OD OUTSIDE DIAMETER <br /> EXPENSES RESULTING FROM FAILURE TO DO SO. CLR CLEAR OH OVERHEAD <br /> CMU CONCRETE MASONRY UNIT OPNG OPENING <br /> 8. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS,THE COL COLUMN OPP OPPOSITE J <br /> CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CONSTRUCTION CONC CONCRETE PCS PERSONAL COMMUNICATION SYSTEM a <br /> MANAGER. CONST CONSTRUCTION 2 PLATE 0 UI <br /> CONT CONTINUOUS PR PAIRCe Q <br /> 9. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE TRAYS, CTR CENTER PSI POUNDS PER SQUARE INCH U 0 <br /> ELECTRICAL LINES,AND ANTENNA CABLES. DIA/0 DIAMETER PSF POUNDS PER SQUARE FOOT a ` <br /> DTL DETAIL PT PRESSURE TREATED /I <br /> 10. ROUTING OF ALL CONDUITS,CABLES,CABLE TRAYS,ETC.IS INDICATED AT PROPOSED LOCATIONS ONLY. (E) EXISTING RAD RADIUS <br /> CONFIRM THE EXACT ROUTING WITH THE ON-SITE CONSTRUCTION MANAGER PRIOR TO THE START OF EA EACH RD ROOF DRAIN <br /> WORK. EJ EXPANSION JOINT REINF REINFORCED/REINFORCING <br /> ELEC ELECTRIC/ELECTRICAL REQ'D REQUIRED <br /> 11. ALL DAMAGE OR OPENING UP OF THE EXISTING STRUCTURE MUST BE MADE GOOD TO THE EL ELEVATION RM ROOM <br /> PRE-CONSTRUCTION CONDITION OR BETTER. EQ EQUAL R/W RIGHT OF WAY <br /> EW EACH WAY SCHED SCHEDULE <br /> 12. INSPECTION OF COMPLETED WORK IS REQUIRED BEFORE COVERING UP.PROVIDE A MINIMUM OF 72 EXP EXPANSION SECT SECTION <br /> HOURS NOTICE TO CONSULTANT. EXT EXTERIOR SF SQUARE FOOT J m.t/1 AN N 1V L RSARY <br /> FD FLOOR DRAIN SIM SIMILAR ^ Surveying <br /> 13. REMOVE AND CLEAN UP ANY DEBRIS OR MATERIAL FROM THE SITE THROUGHOUT THE DURATION OF THE FHFB FLEXI RRH 4-PIPE 1900 SQ FT SQUARE FOOT Lac I Engineering <br /> CONTRACT ON A DAILY BASIS AND UPON COMPLETION OF THE WORK AS DIRECTED BY THE FIN FINISH SS STAINLESS STEEL Planning <br /> CONSTRUCTION MANAGER. FIN FLR FINISH FLOOR STD STANDARD <br /> FLR FLOOR STL STEEL <br /> 20210 142nd Avenue NE Ph.425.806.1869 <br /> Woodinville,WA 98072 Fs 425.482.2893 <br /> 14. OBTAIN AND PAY FOR ALL ELECTRICAL PERMITS AND INSPECTIONS REQUIRED FOR COMPLETION OF FSMF FLEXI MULTIRADIO SYSTEM MODULE STRUC STRUCTURAL „„,„..wCeorp.CO11, <br /> WORK AND ACCEPTANCE.PROVIDED CERTIFICATES TO THE CONSTRUCTION MANAGER VERIFYING THAT FTG FOOTING TEMP TEMPORARY <br /> THE WORK CONFORMS TO THE REQUIREMENTS OF ALL CODES AND AUTHORITIES HAVING JURISDICTION. GA GAUGE THK THICK <br /> GALV GALVANIZED TMA TOWER MOUNTED ANTENNA DATE: 6-14-18 <br /> 15. PROVIDE T-MOBILE WITH A WRITTEN WARRANTY,EFFECTIVE FOR ONE YEAR AFTER DATE OF GYP GYPSUM T.O. TOP OF DRAWN BY: ENS <br /> ACCEPTANCE.FOR THE COMPLETE INSTALLATION REPAIR OR REPLACE ANY DEFECTS ARISING DURING GB GYPSUM BOARD TOS TOP OF STEEL CHECKED BY: RBH <br /> THIS PERIOD AT NO EXTRA COST TO T-MOBILE. HM HOLLOW METAL TOC TOP OF CONCRETE <br /> HOR HORIZONTAL TYP TYPICAL <br /> 16. NO DEVIATIONS FROM DESIGN SHOWN ON THESE DRAWINGS IS ALLOWED WITHOUT WRITTEN APPROVAL HR HOUR UNO UNLESS NOTED OTHERWISE SUBMITTALS <br /> E FROM THE CONSULTANT.FAILURE TO OBSERVE THIS RULE MAY RESULT IN CONTRACTOR CORRECTING HT HEIGHT VERT VERTICAL REV DATE DESCRIPTION BY <br /> THE INSTALLATION AT THEIR EXPENSE. HVAC HEATING VENTILATION AIR CONDITIONING W/ WITH 1 614-18 PREUNONARV CONSTRUCTION ENS <br /> ai INSUL INSULATION WWM WELDED WIRE MESH 2 8-2618 FINAL CONSTRUCTION AAL <br /> I 17. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES,REGULATIONS AND SAFETY INT INTERIOR <br /> REGULATIONS,ALL OSHA REGULATIONS,ALL PUBLIC AND MUNICIPAL AUTHORITIES,AND ANY UTILITY <br /> COMPANIES'REGULATIONS AND DIRECTIVES. <br /> 18. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE SCOPE OF WORK.EXACT <br /> DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD.THE CONTRACTOR IS TO VERIFY THE <br /> DIMENSIONS AND LOCATIONS AND REPORT ANY AND ALL DISCREPANCIES TO REPRESENTATIVE.ANY <br /> 15 MINOR ERRORS AND OMISSIONS IN THE DRAWINGS AND SPECIFICATIONS DO NOT EXCUSE THE <br /> E CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE - 8828 REGISTERED <br /> INTENT OF THESE DOCUMENTS. lb ARCHITECT <br /> 0 19. VERIFICATION THAT EXISTING MONOPOLE CAN SUPPORT THE PROPOSED ANTENNA,COAX AND ��' 1/'.e �/ <br /> ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. REH C . ALL <br /> 01 STATE OF WASHINGTON I sv <br /> 20. ANTENNA AZIMUTHS SHOWN ON THESE DRAWINGS ARE BASED ON TRUE NORTH.ALL AZIMUTHS MUST BE y <br /> VERIFIED WITH THE CORRECT SMR PRIOR TO CONSTRUCTION. <br /> / APPROVAL STAMP <br /> LEGEND AND SYMBOLS: <br /> CHAIN LINK FENCE - x x <br /> CEDAR FENCE ❑ ❑ <br /> POWER P <br /> UNDERGROUND POWER UCP <br /> TELCO T <br /> UNDERGROUND TELCO UCT SITE <br /> OVERHEAD POWER OR — <br /> BOUNDARY SE01686A <br /> ii CENTERLINE - <br /> SITE NAME:NORPRO <br /> s REVISION BUG AL <br /> 0 2215 MERRILL CREEK PARKWAY <br /> a EVERETT,WA 98203 <br /> ELEVATION PROPOSED ELEVATION <br /> 0'-0"AGL Z SHEET TITLE <br /> N GENERAL NOTES <br /> DETAIL NUMBER a <br /> i. e <br /> SHEET NUMBER <br /> uRk <br /> — Call 2 Bushes Days Before You Dig 0 <br /> o n�I 1-800-424-5555 w SHEET NUMBER <br /> SECTION BUG /�� �/� d <br /> .o Utlttles Underground Location Center F <br /> DAONTANAwABHINGTOl) - G-1 .0 <br /> o U <br /> U <br />
The URL can be used to link to this page
Your browser does not support the video tag.