My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10507 ROSEWOOD AVE 2019-07-08
>
Address Records
>
ROSEWOOD AVE
>
10507
>
10507 ROSEWOOD AVE 2019-07-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2019 1:56:08 PM
Creation date
7/8/2019 1:56:07 PM
Metadata
Fields
Template:
Address Document
Street Name
ROSEWOOD AVE
Street Number
10507
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WAC 296-46B-900: ELECTRICAL PLAN REVIEW <br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required.Then select the box next to(a)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br /> required,select the box next to(b)and(c)to acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> . ,r <br /> • <br /> *If item(a)-(ii, iii,or V) is(;elected,the Work must also oomply with section (a)-(vii).See arrow flow chart below. <br /> (3)Electrical plan review. <br /> 0 (a)Electrical plan review is not required for: <br /> ❑ (i)Low voltage systems; <br /> 4-1:1 (ii)Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ❑ (iii)Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution system <br /> ❑ does not include: <br /> (A)Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2;or <br /> (C)A required fire pump system. <br /> ❑ (v)Modifications to existing electrical installations where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B)Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (C)Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br /> and <br /> (D)Service or feeder load calculations are increased by 5%or less. <br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell, or wind electric system(s)with a total <br /> ❑ rating of 9600 watts or less. <br /> (vii)For installations in (a)(ii), (iii),and(v)of this subsection to be considered,the following must be available <br /> ❑ to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed;and <br /> (D)Provide information showing that the service and feeder(s)supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical, dental, and chiropractic clinic"of which is a clinic or <br /> ❑ physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> ▪ (b)Electrical plan review is required for all other new or altered electrical projects in educational, institutional,or health care <br /> ▪ occupancies defined in this chapter. <br /> 0 (c)If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Ta1r10900.1 Table 900=2 <br /> Health er Personal Care Facilities Educational attd institutional Facilit es.Places of Assernh y.or Other Facilities <br /> M"alr3tAN'PersaraaiCare Facility Plan Review Educational;Institutional.or Pian Review <br /> type__._�_. Requirad� Outer Facility Types tte .rireci <br /> VOF <br /> t rr.r:ii,nG!n Inrt-trrr Yes <br /> `.eu.aticrGl �t5_ <br /> earn inft KIVAvn_i tet <br /> eie;e Yes <br /> c•lor,fxr:tlial• Yes <br /> ri+rresrrehoikr!+n.+5 picas Yes Notes to Ta isles 5 .1 and 9C0-2, <br /> e yehrz,ri'•;h+srritai Yr i.c cityei ^cr::ed o=c=_'ec r ra. s1 Tcr. <br /> 4 tF�n!tkrhn,r,.4 Yes r-ay recu.re p a,.re+;e...,' 'aC t tjues <br /> nri u"t,torysurge,y f silty Yes re,.ewsd c,y t e eca-tn•s_^a. <br /> f!+r,q•ihtN'r5dia+;:rtrl4jlt Yes <br /> -esl;i=ntsel t-•cat++ent fats Icy Yes <br /> 01,0fic ed}€r vlc {_ Iitty Yes <br /> tlai e'*.uhllitatior• Yes PERMIT# Page 2-Plan Review <br /> T:N .).7 <br /> bei�te <br />
The URL can be used to link to this page
Your browser does not support the video tag.