f (" )APrl 41-191 <br /> Structural Calculations Cover Sheet <br /> Project Number: 2018.046 Date: June 13,2018 <br /> Project Name: Cain Architect: <br /> Structural Design For: Structural design for a remodel <br /> Construction Type: Conventional wood framed construction. <br /> CODES <br /> 2015 International Building Code(IBC) S.AP0 <br /> 2015 NDSWas <br /> CP 41/ <br /> ASCE 7-10 <br /> LOADS - <br /> 1(IA er-"*.;, • IQ <br /> Dead Loads As required eto/3AL <br /> -9, -•\•% <br /> Roof snow Load 25 psf \---- <br /> 44-r:Irlrit4 <br /> Material Design Values <br /> Soils(assumed) Minimum 2,000 psf allowed bearing(subject to field verification) <br /> Concrete Pc=2,500 psi; 5-1/2 sack mix,or alternate mix pre-approved by bldg. dept. <br /> Reinforcing Grade 40 or 60; Fy=40,000 psi minimum <br /> Sawn Lumber Joists, Rafters: Hem-Fir#2 and better <br /> Beams: DF-L#2 <br /> Posts: DF-L#2 <br /> Studs &Plates: Hem-Fir Standard <br /> Anchor Bolts F1554 Anchor Bolts,A307 other bolts <br /> THIS SET OF <br /> SHALL <br /> MAVV/NGS <br /> n Pt SITE <br /> „1„,„ <br /> Kr AL <br /> .-L <br /> CONSULTING STRUCTURAL ENGINEERING SERVICES,INC. <br /> 6311 - 17th Avenue NE, Seattle WA 98115 (206)527-1288 email john@cses-engineering.corn <br /> Structural Engineering Consulting and Design <br />