Laserfiche WebLink
I <br /> Tier 2 I <br /> Approval Requirements The Reclamation Facility shall have a Quality Control <br /> Plan (QCP) in accordance with WSDOT QC 9"Standard <br /> Practice for Approval of Reclamation Facilities of <br /> WSDOT Recycled Concrete and Returned Concrete". <br /> The Reclamation Facility's QCP shall be submitted and <br /> approved by the WSDOT State Materials Laboratory. <br /> Once accepted,any changes to the QCP will require a <br /> new QCP to be submitted for acceptance. <br /> Evaluation of aggregate source properties(LA Wear and <br /> Degradation)for the recycled concrete aggregate is not <br /> required. <br /> Acceptance Requirements Certification of toxicity characteristics in accordance with <br /> Section 9-03.21(1), required if requested. <br /> Field acceptance testing in accordance with Section 3-04 <br /> is required. <br /> Provide certification in accordance with WSDOT QC 9 for <br /> every lot. A lot shall be no larger than 10,000 tons. <br /> Approved to provide the following Aggregate Materials: <br /> Tier 1 aggregate materials <br /> 9-03.1 Coarse Aggregate for Commercial Concrete or Concrete class 3000 <br /> 9-03.9(1) Ballast <br /> 9-03.9(2) Permeable Ballast <br /> 9-03.9(3) Crushed Surfacing <br /> 9-03.12(1)A Gravel Backfill for Foundations Class A <br /> 1 <br /> Tier 3 <br /> Approval Requirements The Reclamation Facility shall have a Quality Control <br /> Plan (QCP) in accordance with WSDOT QC 10 <br /> "Standard Practice for Approval of Reclamation Facilities <br /> of Recycled Concrete Aggregates from Stockpiles of <br /> Unknown Sources". The Reclamation Facility's QCP <br /> shall be submitted and approved by the WSDOT State <br /> Materials Laboratory. Once accepted, any changes to <br /> the QCP will require a new QCP to be submitted for I <br /> acceptance. <br /> Evaluation of aggregate source properties (LA Wear and <br /> Degradation)for the recycled concrete aggregate is <br /> required. <br /> Acceptance Requirements Certification of toxicity characteristics in accordance with <br /> Section 9-03.21(1) is required. <br /> Field acceptance testing in accordance with Section 3-04 <br /> is required. <br /> Provide certification in accordance with WSDOT QC 10 <br /> for every lot. A lot shall be no larger than 10,000 tons <br /> Approved to provide the following Aggregate Materials: <br /> Tier 1 aggregate materials <br /> 9-03.1 Coarse Aggregate for Commercial Concrete or Concrete class 3000 <br /> 9-03.9(1) Ballast <br /> 9-03.9(2) Permeable Ballast <br /> City of Everett Page AM-88 Amendments <br /> Everett Downtown Streetscape Improvement March 22, 2019 <br />