Laserfiche WebLink
B(.�/ 306- oO / <br /> Scope of work at 3112 15th St, Everett, WA <br /> ri or <br /> x8 <br /> The entire stairway,landing leading to the second floor and the second-floo deck was replaced end of <br /> September 2010. All work was permitted and inspected. The four supporting beams and two of the <br /> supporting 6"x 6" posts were still good and therefore were reused when the stairs and deck were <br /> replaced in 2010. <br /> These four supporting beams now need to be replaced. The scope of this permit request is to replace <br /> these four beams with the same size and design that was approved eight years ago. I am also asking to <br /> replace the stringers supporting the stairs to the entry of apartment A on the first floor. <br /> I have already replaced three of the four beams, before a stop work order was posted at the property. I <br /> am asking permission to replace the last beam and have the work inspected. ,, <br /> 7- i s-es6X$ Sec <br /> The design and construction of these replacement beams i-- • - - . ' <_ <br /> Three pressuretreated two by six boards screwed together with a half inch spacer between so that it's <br /> thickness will match the 6"x 6" post they are sitting on. The spacer allows a T shaped metal strap to be <br /> nailed on the face and back side,tying the new beam to its supporting post.This half-inch plywood <br /> spacer was mopped on all sides with a wood preservative before the beams were built. The.beams are <br /> already built and three of them are installed so I hope their design will be approved. The beams will be <br /> tied to the joists sitting on top of the beams with the same Simpson H1 straps that were approved with <br /> the last permit. <br /> All the wood used in the construction of the stairs, landing and second story deck is pressure treated <br /> and in good condition. <br /> I have included two drawings that I found that were part of the 2010 permit. It gives you some as-built <br /> dimensions. <br /> The other item to be done is the replacement of the stringers for the three step stairs to the landing of <br /> apartment A on the first floor. Currently there are only two stair stringers,one on each end. I would <br /> like to add a third stringer down the middle. I plan on buying these stringers precut and pressure <br /> treated at Lowes. I will also replace any stair tread boards(three pressure treated 2"x 4")as needed. I <br /> will support the stringers by tying them to the landing with joist hangers. <br />