6107 BERKSHIRE DR T MOBILE ANTENNA 2019-07-12
>
Address Records
>
BERKSHIRE DR
>
6107
>
T MOBILE ANTENNA
>
6107 BERKSHIRE DR T MOBILE ANTENNA 2019-07-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2019 8:55:20 AM
Creation date
7/12/2019 8:54:35 AM
Metadata
Fields
Template:
Address Document
Street Name
BERKSHIRE DR
Street Number
6107
Tenant Name
T MOBILE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
127
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> STRANDED CU WIRE WITH GREEN,600V, <br /> THHN/THWN INSULATION.SIZE AS <br /> SPECIFIED <br /> O_ <br /> COPPER GROUND BAR _ _ _ ,_, 202 <br /> ON WALL,ICE BRIDGE, W <br /> FLOOR OR ON z <br /> NEW COAXIAL GROUND KITS W/LONG ANTENNA TOWERcc <br /> BARREL COMPRESSION DOUBLE �� V� v o <br /> LUGS,ATTACH TO GROUND BAR& / P 6(:) ,) <br /> n�\ n, <br /> INSTALL BY ANTENNA CONTRACTOR O '`)1/4 0 Q OO V O O W z <br /> (CADWELD TYPE-GL) <br /> © •O O OO OO OOO OO O 0 OO OO ri <br /> •/��� o <br /> �J m <br /> PANT SCHEME SPECIFICATIONS: OO O O l O O 0 0 0 DO � l ' I <br /> NEW 4"x20"x1/4 THK COPPER TYPICALLY O <br /> GROUND BAR INSTALLED BY PRODUCER(P) 0 12"TO 24" <br /> - GENERAL CONTRACTOR CONNECTS TO WIRELESS EQUIPMENT TWO HOLE LUG,BOLTED J 120"MAX <br /> v I CABINETS,CABLE ENTRANCE GROUND TO GROUND BAR USING ANTENNA CABLE 2 1/2" <br /> • <br /> BAR(CEGB),MAIN DISTRIBUTION FRAME 3/8"-16x1/4"STAINLESS 0 MAX 1. ra?I'i <br /> 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 GROUND BAR(MDFB),AND STANDBY STEEL HEX HEAD BOLTS F'- Zw <br /> O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 kr ENGINE GENERATOR SET FRAME AND AND HARDWARE <br /> OTHER NOISE PRODUCING EQUIPMENT. ��C 7 J <br /> O U7 <br /> .600 0 0 0 0 0 0 0 0 0 oo <br /> I^I ABSORBER(A) 'TWO HOLE LUG,TO BE USED WITH#2 AWG WEATHERPROOFING KIT CC Q <br /> uJ 101 CONNECTS TO THE EARTH ELECTRODE SOLID TINNED BARE CU WIRE OR STRANDED (SEE NOTE 3) 0 U <br /> I 20"MGB OR 10"ANTENNA AGB SYSTEM INCLUDING CENTRAL OFFICE CU WIRE WITH GREEN,600V,TO ANTENNA CABLE <br /> FIELD VERIFY GROUND GRID,BUILDING STRUCTURAL STRUCTURE,BUILDING RING GROUND OR CABLE GROUND KIT CONNECTOR <br /> GROUND,METALLIC WATER PIPE SYSTEM, MGB <br /> ANTENNA SUPPORTING STRUCTURE #6 AWG STRANDED COPPER <br /> #2 SOLID BARE TINNED GROUND SYSTEM,AND ELECTRICAL GROUND WIRE(GROUNDED <br /> COPPER WIRE CADWELD SERVICE ENTRANCE GROUND. ;OO GDROUND BAR).SEE NOTE <br /> AN2 <br /> (TYPE-GL) NON-ISOLATED(N) <br /> CONNECTS TO EQUIPMENT NOT IN AN <br /> NOTE ISOLATED GROUND ZONE(IGZ)SUCH AS <br /> CBN EQUIPMENT FRAME GROUNDS AND <br /> 1. COAT ALL MECHANICAL CONNECTIONS WITH"NOOX"OR APPROVED EQUAL. NOTES <br /> DC GROUND CONDUCTORS FOR DC 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND Surveying <br /> ngine <br /> 2. ALL EXISTING&NEW TOWER GROUNDING BARS SHALL BE ATTACHED POWER SYSTEMS THAT SERVE CBN OR BOTH CBN AND IBN EQUIPMENT NOTE ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. LDC PPIa"Planning-n. <br /> DIRECTLY TO THE TOWER WITHOUT ISOLATORS. NO WELDING OR 2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE <br /> *GROUND BARS AT BOTTOM OF 20210 142nd Avenue NI Pb 421806.1869 <br /> DRILLING PERMITTED. KIT WITH TWO HOLE LUG. <br /> ISOLATED(I) TOWERS OR MONOPOLES SHALLWoodinville,142d WA ue N h.425882.1893 <br /> CONNECTS TO THE SINGLE POINT 3. COLD WEATHERPROOFINGINKSHALL <br /> SHALL USED.TWO-PART TAPE KIT, <br /> 3. EXISTING HOME RUN GROUND(S)TO BE REMOVED. CONNECTION BAR(SPCB)FOR IBN USE EXOTHERMIC CONNECTION. COLD SHRINK SHALL NOT BE <br /> EQUIPMENT <br /> - <br /> DATE: 4-19-18 <br /> GROUND BAR 6 GROUND BAR CONNNECTION 5 CABLE GROUNDING DETAIL A DRAWN BY: AAL <br /> E I 22"x34"SCALE:3/16"=1'-0" I 11"x17"SCALE:3/32"=1'-0" I 22"x34"SCALE:1"=1,-0" I 11"x17"SCALE:1/2"=1'-0" I 22"x34"SCALE:2"=1'-0" I 11"x17"SCALE:1"=1'-0" �} CHECKED BY: RBH <br /> SUBMITTALS <br /> REV DATE DESCRIPTION I BY <br /> 1 419.10 PRELIMINARY CONSTRUCTION AOL <br /> 2 10-12-18 RPCC.REDLINES SRN <br /> S 10-23.18 FINAL CONSTRUCTION Km <br /> .85 il '��TO ANTENNAS ��� <br /> $ RX2 IIITXt/RX1 TYPE TA TYPE W TYPE GT <br /> w w i 1 , 8828 <br /> REGISTERED <br /> o ARCHITECT <br /> v WEATHERPROOFING ATA •�I' - j�� <br /> o JUMPER REQUIRED ONLY KIT(TYP) ��� 0 �• <br /> '2 FOR 1-5/8"0 COAX OR FOR y y 9e�! � �(�� RICHAR• ALU <br /> V 11 . /' STATE OFWASHINGTOH <br /> EASE OF CONNECTION ' y, <br /> 1 (TYP) IXPIRES:8-20-19 .(�` <br /> II <br /> I I I <br /> STANDARD GROUND Q <br /> KIT(TYP)SEE NOTE. WV TYPE VN TYPE NC TYPE SS <br /> CONNECTOR �! �I APPROVAL STAMP <br /> WEATHERPROOFING Al AR PI <br /> oKIT(TYP)SEE NOTE 2 <t'' v f #6 AWG J <br /> COPPER ANTENNA GROUND <br /> E ANTENNA CABLE TO BAR,ATTACHED DIRECTLY TOtilitv [-- <br /> [:0 <br /> BTS EQUIPMENT(TYP) ' TOWER WITHOUT ISOLATOR. ` ; <br /> NO WELDING OR DRILLING <br /> Ji <br /> PERMITTED. <br /> TYPE VS TYPE VB TYPE PT <br /> S LU <br /> __ TO GROUND -J SITE <br /> _ RING a SE01603A <br /> O <br /> lr. <br /> r�l <br /> I <br /> EVERETT MONOPOLE <br /> NOTES $ \`�;�, F 6107 BERKSHIRE DR <br /> 0 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND tx <br /> �'s' EVERETT,WA 98203 <br /> AND ALWAYS DIRECT GROUND WIRE DOWN TO LU <br /> m ANTENNA GROUND BAR. TYPE GY TYPE GR R TYPE GL LU <br /> SHEET TITLE <br /> R 2. WEATHERPROOFING SHALL BE ANDREWS.(TYPE r CD GROUNDING DETAILS <br /> E AND PART NUMBER AS SUPPLIED OR 1 ! N <br /> RECOMMENDED BY CABLE MANUFACTURER.) co <br /> a LiiSHEET NUMBER <br /> ANTENNA GROUND BAR 3 NOT USED 2 TYPICAL CALDWELD CONNECTIONS I E-2.O <br /> 6 I 22"x34"SCALE:1 1/2"=1'-0" I 11"x17"SCALE:3/4"=1'-0" I 22"x34"SCALE:N.T.S. I 11"x17"SCALE:N.T.S. I 22"x34"SCALE:N.T.S. I 11"x17"SCALE:N.T.S. o <br /> U <br />