4 <br /> Date: August 1,2018 <br /> Lukasz Banach Tower Engineering Professionals <br /> Crown Castle 326 Tryon Road <br /> 2055 S. Stearman Drive Raleigh, NC 27603 <br /> Chandler, AZ 85286 (919) 661-6351 <br /> Subject: Structural Modification Analysis Report <br /> Carrier Designation: T-Mobile Co-Locate <br /> Carrier Site Number: SE01603A <br /> Carrier Site Name: Everett Monopole <br /> Crown Castle Designation: Crown Castle BU Number: 823967 <br /> Crown Castle Site Name: Everett Monopole <br /> Crown Castle JDE Job Number: 486216 <br /> Crown Castle Work Order Number: 1599564 <br /> Crown Castle Order Number: 427333 Rev. 0 <br /> Engineering Firm Designation: TEP Project Number: 46303.166106 <br /> Site Data: 6107 Berkshire Dr., Everett,Snohomish County,WA 98203 <br /> Latitude 47°56'34.49" Longitude-122°12'45.47" <br /> 127 Foot-Monopole Tower <br /> Dear Lukasz Banach, <br /> Tower Engineering Professionals is pleased to submit this "Structural Modification Analysis Report" to <br /> determine the structural integrity of the above mentioned tower. This analysis has been performed in <br /> accordance with the Crown Castle Structural `Statement of Work' and the terms of Crown Castle Purchase <br /> Order Number 1217993, in accordance with order 427333, revision 0. <br /> The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we <br /> have determined the tower stress level for the structure and foundation, under the following load case,to be: <br /> LC4: Modified Structure with Existing/Reserved+ Proposed Equipment Sufficient Capacity <br /> Note:See Table I and Table II for the proposed and existing/reserved loading,respectively. <br /> This analysis has been performed in accordance with the 2015 International Building Code based upon an <br /> ultimate 3-second gust wind speed of 110 mph converted to a nominal 3-second gust wind speed of 85 mph per <br /> Section 1609.3.1 as required for use in the TIA-222-G Standard per Exception#5 of Section 1609.1.1. Exposure <br /> Category C and Risk Category II were used in this analysis. <br /> All modifications and equipment proposed in this report shall be installed in accordance with the appurtenances <br /> listed in Tables 1 and 2 and the attached drawings for the determined available structural capacity to be <br /> effective. <br /> We at Tower Engineering Professionals appreciate the opportunity of providing our continuing professional <br /> services to you and Crown Castle. If you have any questions or need further . istance on this or any other <br /> projects please give us a call. <br /> •SID�� C� <br /> Structural analysis prepared by:Travis L. Infante, E.I./JLW <br /> Respectfully submitted by: ygt7 <br /> O <br /> O. X <br /> Ronald E. Glover, P.E., S.E. 0 %5292EAm, �p�' ' <br /> SS'ONA.. EAG <br /> 08/01/2018 <br />