WAC 296-46B-900: ELECTRICAL PLAN REVIEW <br /> DIRECTIONS:Read the WAC section below to determine if plan review is required or not required.Then select the box next to(a)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900.If plan review is <br /> required,select the box next to(b)and(c)to acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> *If item(a)-(ii, iii,or v)is selected,the work must also comply with section (a)-(vii).See arrow flow chart below. <br /> (3)Electrical plan review. <br /> gl (a) Electrical plan review is not required for: <br /> (i)Low voltage systems; <br /> i—❑ (ii)Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ❑ (iii)Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution system <br /> ❑ does not include: <br /> (A) Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2;or <br /> (C)A required fire pump system. <br /> ❑ (v)Modifications to existing electrical installations where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B)Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (C)Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br /> and <br /> (D)Service or feeder load calculations are increased by 5%or less. <br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell, or wind electric system(s)with a total <br /> o rating of 9600 watts or less. <br /> (vii) For installations in(a)(ii),(iii),and(v)of this subsection to be considered,the following must be available <br /> O to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed;and <br /> (D)Provide information showing that the service and feeder(s)supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical,dental, and chiropractic clinic"of which is a clinic or <br /> ® physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> 1-1 (b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional,or health care <br /> Li occupancies defined in this chapter. <br /> 0 (c) If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Taihfe 9Otw r" Toole SOO-2 <br /> Health or Personal Care Facilities Educational aria Institutional.Facilities,•Paces of Asser"%b y.or Other Fatiiities <br /> M�+EaicN dr <br /> Perste-tat Carie Faciitty Plan Review Educational. !=%sti[ueioe%aV.or Plan R.ev€FM <br /> Typo Requirod <br /> .__ Other Fac,4ty Types Peq. reci <br /> yen ,,p.... Yee' <br /> 1.re ts;1,41-1-tort!" Yes <br /> 4e1;r itr tvdyn Yes <br /> a iat r 'iip"fir:+liw;• Yes <br /> Pt I,+,.[o,10,thtdism!v4pItal Yes Notes to Tables 500.1 arid 900-2 <br /> p tyr.ftiA+:°t,., pitusl Yrs i e®*y a 1 c MCC. sc r .a. r,sp ecti.r s <br /> Yes r a;rec,i.r,ra r <_r e , =or ti tjc_e <br /> ,r1�WrrYO yuWri;.ryasC'Hy Yes rey ewe rr tee o. etr-_et. <br /> ,',+ ,rie ,.4i!ail1. Yes <br /> tiro:sl,ir,+rlt+:+lf"ei='t,esr§T,fdt:lril'y Yes <br /> nl 'C. r+ �Fvlc f Puby Yes <br /> r+as'tr€etioi fr s'rahlllcacioe Yes PERMIT# Page 2-Plan Review <br /> ,�at,3r <br />