Laserfiche WebLink
STRUCTURAL NOTES 4= <br /> (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) <br /> (2)ROWS OF(16)0.148"0 NAILS EA <br /> CODE • <br /> END,(32)TOTAL PER NOTE 3,NP y^`s NOTES: <br /> ALL MATERIALS,WORKMANSHIP,DESIGN,AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS,SPECIFICATIONS,AND THE �.' " 1.PROVIDE 0.148"0 x 3"NAILS,STAGGERED 0 24"OC W/11/2" ENGINEERING <br /> INTERNATIONAL BUILDING CODE(IBC),2015 EDITION.SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS '\ EMBED. <br /> ARE TO BE THE LATEST EDITION. /� `\ SISTER NEW 2x6 DF#1 2.PROVIDE 19/32 PLYWOOD GUSSET(G=0.5 MIN);STAGGER NAILS 250 4TH AVE. S. SUITE 200 <br /> • <br /> TO EXIST TOP CHORD TO MEET SPACING REQUIREMENTS PER NOTE 3. EDMONDS, WASHINGTON 98020 <br /> DESIGN LOADS /./-- � PER NOTE 1 3.PRE-BORE NAIL HOLES AND PROVIDER MINIMUM NAIL SPACING <br /> / / "� � \ -. OF 11/2"WITH 1"EDGE DISTANCE.PROVIDEAMINIMUM NAIL PHONE (425) 778-8500 <br /> DEAD LOADS: / � / ��,��� EMBEDMENT OFI I/2" <br /> ROOF 12 PSF / .` // \\\ 4.DO NOT REMOVE OR NAIL THROUGH EXIST TRUSS PLATES. FAX (425) 778-5536 <br /> I ~ -�\ S.IF WOOD SPLITS,PRE-DRILL HOLES AND USE WOOD SCREWS OF <br /> LIVE LOADS: \ \\ <br /> ROOF(SNOW LOAD) 25 PSF INFILL CUTS W/DF#1 SAME DIAMETER IN LIEU OF NAILS. <br /> / `\� <br /> SHIMS 0 SIM SECTION \ <br /> (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.10). / / . <br /> LUMBER /"` l/" ( `\ \. NAILSEA) S ND,(32)TOTAL jMOT7ryTLr <br /> • / • / \ PER NOTE 3,TYP �.+ "; <br /> ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED.ALL LUMBER SHALL BE IN ACCORDANCE WITH WVVPA GRADING (2)ROWS OF(16)0.148"0 �; ;/ �\� WA I> <br /> RULES,KILN-DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: NAILS EA END,(32)TOTAL \ \. Q y S <br /> PER NOTE 3,TYP / j ( - A •lIA <br /> SIZE CLASSIFICATION SPECIES GRADE - Fb(PSI) Fc(PSI) / - �\�\ • A w e� /, <br /> SLEEPERS DOUG-FIR STUD 700 - ',,i10.-1 <br /> / /� "��. ~ "'/ <br /> « `�' �� -�� " <br /> LIGHT FRAMING(STUDS) HEM-FIR STUD 675 800 -' ' <br /> rn <br /> 2x JOISTS AND PLANKS HEM-FIR #2 850 /-f �..... ---_ __ _...._� _.._,.._ _._.__—_.___ . .__ .,.., .._._.........._ ..,, _� <br /> PLATES AND BLOCKING HEM-FIR #2 850 - • ..i EXIST TRUSS PLATE TO \\ "'' .. . <br /> 6x AND LARGER BEAMS AND DOUG-FIR #2 875 REMAIN,TYP `J �� <br /> •C�i _ 46548 �S <br /> STRINGERS `TUR q <br /> 4x AND SMALLER BEAMS AND HEM-FIR #2 850 - "" " 1Nj SIGNAL #(. <br /> STRINGERS <br /> ALL POSTS AND TIMBERS DOUG-FIR #1 1200 1000 " <br /> REFER TO PLAN NOTES,SCHEDULES,AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. OJ/ISI/�,/I/� <br /> l <br /> UNLESS NOTED OTHERWISE IN THE PLANS,ALL WOOD AND WOOD-BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT TRUSS SECTION DESIGN: CGP <br /> WITH CONCRETE,MASONRY,OR WITHIN 8"OF SOIL SHALL BE PRESERVATIVE-TREATED BY VACUUM-PRESSURE IMPREGNATIONCD <br /> IN ACCORDANCE WITH AWPA STANDARD Ul. SCALE: 1/4"=1'-0" <br /> (12)0.148"0 NAILS,(24) DRAWN: ATD <br /> NAILS,BOLTS,AND METAL CONNECTORS FOR WOOD TOTAL;SEE NOTE 2 <br /> ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS(NDS)FOR WOOD � CHECK: MTM <br /> CONSTRUCTION,LATEST EDITION.NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE.ALL NAILS (4)0.148"0 NAILS, / % �. <br /> CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING SEE NOTED /";/ \ (4)0.148"0 NAILS, JOB N0: "19057.10 <br /> MINIMUM GUIDELINES: ' " \" SEE NOTE 2 <br /> NAIL SHANK 0 MIN LENGTH i ,..-->/- // %\ <br /> �7e / � /i ` DATE: 03/14/19 <br /> 8d COMMON 0.1310 2 1/2"SHANK (4)0.148"0 NAILS, <br /> fX�,�d i,.. (4)0.148"O NAILS, <br /> SEE NOTE 2 �a SEE NOTE 2 Cr)10d COMMON 0:1480 3"SHANK // g,{4 \;1'� V r n <br /> i (2 ( 0 <br /> 10d COMMON 0.1480 31"SHANK <br /> 0/// . �// <br /> 16d COMMON 0.1820 312"SHANK (4)4148"0 NAILS, " J <br /> SEE NOTED \ 000000p..." <br /> f :� \ (4)0.148"O NAILS, Q /'�� <br /> 10d BOX NAILS MAYBE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING,FRAMING MEMBERS MAYBE ` / ! \ SEE NOTE 2 0— W <br /> NAILED WITH 16d SINKERS(0.148"0 x 3 1/4"),BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN �j9 x - NEW SISTERED % <br /> THIS DRAWING SET-ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF /4. 2x6 BEHIND %- L/-�V/ <br /> CONSTRUCTION. / % (4)0.148"0 NAILS, l SE NOTE0 NAILS/ 'Y 1: <br /> 40000/11000" <br /> :� SEE NOTED j O 0 \" SEE NOTE <br /> ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307.PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS (11)0.148"0 �/ 4 0.148" NAILS, Lai <br /> AND LAG SCREWS BEARING ON WOOD.LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS NAILS,SEE ;/ \\ / <br /> PER NDS 11.1.3. NOTE 2 �_ (4)0.148"0 NAILS, SEE NOTE 2 / / <br /> ' SEE NOTE 2 \ \I (11)0.148'0 NAILS, CD a <br /> CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE"STRONG-TIE"BY SIMPSON COMPANY,CATALOG TO BE THE ' #%� �k� '' .P* SEE NOTE 2 <br /> LATEST EDITION,OR ENGINEER APPROVED EQUAL CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE / •• ,—._...._._.........___.__...._.__...._—_ ._ ...—_ 'i' 'i' 3' $...__... L ke.- <br /> Q <br /> MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. �,/ x'' - '"-\�� = 7 <br /> WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS,PLACE ONE-HALF OF THE NAILS,SCREWS,OR BOLTS IN EACH MEMBER. :/ , EXIST TRUSS PLATE TO ( \ L <br /> INSTALL SOLID BLOCKING AT ALL BERING POINTS.ALL SHIMS SHALL BE SEASONED,DRIED,AND THE SAME GRADE(MINIMUM)AS a NG, R <br /> MEMBERS CONNECTED. - NAILING THHROOUGHUGH <br /> � Q <br /> _ EXIST TRUSS PLATE <br /> GALVANIZATION - .,�,"•V LL <br /> W N <br /> UNLESS NOTED OTHERWISE,STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO ♦2 c O <br /> THE FOLLOWING TABLE: LL /�' L <br /> UNTREATED ACQ-C CBA-A OTHER OTHER PT `W '-- <br /> WOOD <br /> GALVANIZATION CCA-C SBX ACQ-D CA-B BORATE ACZA WOOD TRUSS SECTION OPPOSITE SIDE <br /> G90 X X X SCALE: 1/4,.=l'-0" ~/�/ O <br /> — <br /> HDGG185 X X X X X X ) I I I I I ( Z O J <br /> HDG X X X X X X . S L <br /> 57300 X X X X X X X X L.._._.........—.__ _..____....__._ L-I Z <br /> G90=0.90OZ.OF ZINC PER SQUARE FOOT OF AREA J <br /> G185=1.85 OZ.OF ZINC PER SQUARE FOOT OF AREA (3)2x4 HF#2 F- V") <br /> / ) <br /> " <br /> HDG=HOT DIP GALVANIZED J <br /> Q Q <br /> SST300=TYPE 316L STAINLESS STEEL . <br /> EXISTING BUILDING 0.148"0 X 3"NAILS @ 6"OC, - it,A Ch <br /> STAGGERED BOTH SIDES U <br /> CONTRACTOR SHALL VERIFY ALL DIMENSIONS,MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE - Q <br /> DRAWINGS,AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. " F- <br /> o <br /> CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. I <br /> PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. (4)0.148"x3" . V W U <br /> GENERAL NAILS EACH END, /'�/ <br /> BOTH SIDES L f. D <br /> STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL,CIVIL,ELECTRICAL,AND MECHANICAL DRAWINGS <br /> FOR BIDDING AND CONSTRUCTION.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE <br /> PROCEEDING.ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. O W <br /> CONTRACTOR TO SEE ARCHITECTURAL,CIVIL,ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPE,VENT, / . N > I- <br /> DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. /'' --- - --"---"-.._.._ ,.,_.,„,,__.__...___,___�_.,_,___,_J .Q <br /> 1W (/) <br /> CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT __ .� ----`----- -'—' r <br /> SUPPORT AND STIFFENING ARE INSTALLED- /' <br /> CONTRACTOR-INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR - / <br /> / <br /> APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION.CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS ---------.-. <br /> REQUIREMENT. <br /> DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OP CONSTRUCTION.WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED . q` (;,,,,,9 TRUSS 2 REPAIR <br /> BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN,SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED,SUBJECT TO REVIEW <br /> AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. 1 / v SCALE: 1/2”=1'-0" a <br />