My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
510 W CASINO RD ZOEYS FRIED CHICKEN 2019-07-31
>
Address Records
>
W CASINO RD
>
510
>
ZOEYS FRIED CHICKEN
>
510 W CASINO RD ZOEYS FRIED CHICKEN 2019-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2019 9:16:31 AM
Creation date
7/12/2019 10:03:43 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
510
Tenant Name
ZOEYS FRIED CHICKEN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I. Makeup Air(508): �1 <br /> 1. Applicant shall provide makeup air approximately equal to the exhaust. 02, `A3 CFM. <br /> 2. Makeup air system shall be electronically interlocked with the exhaust system, such that the makeup <br /> air system will operate when the exhaust system is in operation. Provide note on plan sheet no. <br /> 3. Makeup air shall be provided by a mechanical or gravity means of sufficient capacity. Windows and <br /> door openings shall not be used for the purpose of providing makeup air. <br /> Fan Motorized Damper <br /> Make and Model: 455c r/t H,P.: V? Recommended air velocity, 500 fpm <br /> Duct Area <br /> Static Pressure: in. at Requirement= /500= <br /> CFM 2if <br /> - _ CFM/500 fpm <br /> CFM ft.2 <br /> f Y <br /> k(4 Y <br /> YJr 6 Duct Dimension <br /> Duct Dimension: /5t./1/f( ft.2 Requirement= <br /> area <br /> Eff. Damper <br /> Air Velocity /0 3G Opening = X = <br /> = CFM/area ( m ft.2 <br /> CFM area <br /> J. Duct Slope and Cleanout Access (506.3.7, 506.3.8, 506.3.9): <br /> 1. Horizontal duct up to 75' long: Minimum Slope 1/4 in./ft. Proposed: - in./ft. <br /> Horizontal duct more than 75' long: Minimum Slope 1 in./ft. Proposed: <br /> 2. Tight-fitting cleanout doors shall be provided Total Number Proposed: a <br /> at every change in ductwork direction. (WAC506.3.9.1) <br /> 3. Refer to State amendments for vertical ducts. (WAC506.3.9.2) <br /> K. Duct Enclosure (506.3.11): <br /> 1. Ducts penetrating a ceiling, wall or floor shall be enclosed in a duct enclosure having fire rating per <br /> IBC 708.4 from the point of penetration to the outside air. A duct may only penetrate exterior <br /> walls at locations where unprotected openings are permitted by Table 705.8 of 2009 International <br /> Building Code. <br /> Type of Construction Min. Fire-Resistive Proposed Proposed Material <br /> Const. of Enclosure &Construction <br /> I F.R., II F.R. 2 hour hr. <br /> II, Ill, IV, V 1 hour hr. <br /> 2. Duct enclosures shall be separated from the duct by at least 6". (506.3.10) Proposed: (✓c1444Q,in. <br /> 3. Duct enclosures shall be sealed around the duct at the point of penetration and vented to the exterior <br /> through a weather-protected opening. <br /> 4. Duct enclosures shall serve only one kitchen exhaust duct. (See multiple hood venting for <br /> exception.) <br /> 5. Tight-fitting hinged access door shall be provided at each cleanout. Access enclosure doors shall <br /> have a fire-resistance rating equal to the enclosure. An approved sign shall be placed on the access <br /> door. "ACCESS PANEL. DO NOT OBSTRUCT.",;i; <br />