Laserfiche WebLink
Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: ACCESS LASER-TENANT IMPROVEMENT Date 10/23/2017 <br /> tdicUldllull O U maaition- u H onion For Building Department Use <br /> Area NOTE 9 stand alone +existing <br /> O Spaces where<50%of O Spaces where z 50%of Q <br /> luminaires are replaced luminaires are replaced <br /> 1.17 h ®Standard Q Aoartional ttnciency lackage option Q <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE 1 <br /> Location(plan#, Height'-'` Gross Interior Allowed Watts Allowed <br /> room#) Space Type 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> 103 Corridor:manufacturing 10' 100 0.330 33 <br /> 104 Office:Enclosed 10' 114 0.890 101 <br /> 105 Office:Enclosed 10' 114 0.890 101 <br /> 107 Computer room 10' 48 1.370 66 <br /> 108 Conference/meeting/multipurpose 10' 404 0.980 • 396 <br /> 109 Office:Open plan 10' 831 0.780 648 <br /> 109A Office:Enclosed 10' 142 0.890 126 <br /> 109B _ Office:Enclosed 10' 138 0.890 123 <br /> _ <br /> 109C Office:Enclosed 10' 138 0.890 123 <br /> 109D Office:Enclosed 10' 138 0.890 123 <br /> 110A Office:Open plan 10' 685 0.780 534 <br /> 1108 Conference/meeting/multipurpose 10' 746 0.980 731 <br /> 110C Laboratory for medical/industrial/research 10' 178 1.450 258 <br /> 123 Warehouse:Medium/bulky palletized items 23' 1912 0.460 880 <br /> 112 Breakroom(see Lounge/breakroom) 10' 634 <br /> 113 Lobby:elevator 10' 45 0.510 23 <br /> 117 Computer room 10' 43 1.370 59 <br /> 121A Corridor:manufacturing 10' 419 0.330 138 <br /> _ _ _ _ _121 Laboratory for medical/industrial/research 23' 1573 1.450 2281 <br /> 124 Laboratory for medical/industrial/research 10' 2007 1.450 2910 <br /> 125 Laboratory for medical/industrial/research 10' 45 1.450 65 <br /> 126 Laboratory for medical/industrial/research 10' 2822 1.450 4092 <br /> 127 Laboratory for medical/industrial/research 10' 256 1.450 371 <br /> 128 Laboratory for medicallndustrial/research 10' 172 1.450 249 <br /> 129 Laboratory for medical/industrial/research 10' 33 1.450 48 <br /> 130 Laboratory for medical/industrial/research 10' 142 1.450 206 <br /> 131 Laboratory for medical/industrial/research 10' 36 1.450 52 <br /> 132 Laboratory for medical/industrial/research 10' 228 1.450 331 <br /> 133 Laboratory for medical/industrial/research 10' 301 1.450 436 <br /> 134 Restroom:all other 10' 4 4 0.780 34 <br /> 135 Restroom:all other 10' 64 0.780 50 <br /> 136 Restroom:all other 10' 64 0.780 50 <br /> 137 Workshop 10' 537 1.270 682 <br /> 138 Laboratory for medical/industrial/research 10' 340 1.450 493 <br /> 139 Laboratory for medical/industrial/research 10' 1335 1.450 1936 <br /> 100 Lobby:all other 23' 479 0.720 345 <br /> 102 Stairwell 23' 138 0.550 76 <br /> 200 Office:Open plan 9' 1209 0.780 943 <br /> 201 Office:Enclosed 9' 116 0.890 103 <br /> 202 Office:Enclosed 9' 116 0.890 103 <br /> 203 Conference/meeting/multipurpose 9' 204 0.980 200 <br /> 204 Office:Enclosed 9' 149 0.890 133 <br /> 205 Office:Enclosed 9' 200 0.890 178 <br /> 208 Office:Open plan 9' 1649 0.780 1286 <br /> 209 Office:Enclosed 9' 113 0.890 101 <br /> 210 Laboratory for medical/industrial/research 9' 858 1.450 1244 <br /> 211 Corridor:manufacturing 9' 5 0.330 31 <br /> `1 a <br />