1-1/2"SOLVENT OUTLINE OF (E)1-1/2"SOLVENT
<br /> 1"PROCEES CW 8"ROOF DRAIN LEGEND
<br /> 4"AIR 1/2"AIR BEYOND (E)1-1/4"FW40_,/,,
<br /> 4"AIR j' s FS# s FIELD SUPPORT LOCATION
<br /> . ... 1111-}1 - .� • HPS TO 45-03
<br /> 00 0 4 / (E)1/2"N2 jj . III // PRv HEADER s 4 PIPE SUPPORT LOCATION
<br /> ° /MECHANICAL 7PS-#
<br /> R I •
<br /> ROOM
<br /> / I •
<br /> •,m l i ,_ '•• . '' s / PIPE GUIDE LOCATION
<br /> s
<br /> s �_ 14"HPS_—____ —� } EXIST 6"LPC .,(--(-4{
<br /> PS-#
<br /> T � ■�� ANCHOR PS-3
<br /> ro�
<br /> n`� ' s X s PIPE ANCHOR LOCATION
<br /> PS-6 TIE-IN TO EXIST 6"CW
<br /> (E) CONDUIT �� - 1-1/2"SOLVENTf 1 PS #
<br /> EXISTING ..e TIE-IN TO (SEE ELEC.) iii EL. 558' 6" la. AI. _ — ,- .,,,,,,,„,,"a„".,,.�,,,,,,,,,„,,,,,e
<br /> EL 55
<br /> CRANE RAIL a o 1-1 2"SOLVENT ° —
<br /> SEE STRUC.
<br /> I (i- • FOR DOOR /It
<br /> 1-(E)1-1/2"SOLVENT Z-11REINFORCING - - - - - H- GENERAL NOTES
<br /> I
<br /> c0 ) a° , • I ° [ EXISTING 12" 1. STEAM PIPE TO SLOPE AT 1" PER 40'-0".
<br /> (E)LADDER UNNERSAL TIE
<br /> _ __ 14"HPS ___— EXPANSION 2. SEE DETAIL SHEET M578-04 FOR TYPICAL
<br /> — JOINT STEAM TRAP PIPING AND COMPONENTS.
<br /> 1 (IIISEE ELECTRICAL)ELECTRICAL C�y� �� 3. CONDENSATE PIPING TO SLOPE AT 2" PER
<br /> MiliiiiiiiiigiiiiIiENIMIn•! EL 545'-6" 1-... EL S45'}6”
<br /> fl't
<br /> _ L 40-0".i/i •/°i /•/ ' G---
<br /> \ \
<br /> OU UNE CONCRETE _ _ �_ EL. 550-0"f
<br /> • /�\//\ \�� WALLS BEYOND Z a a _I�EXISTING 12" DRIP
<br /> /4 I I © "----
<br /> REGI TRAP TO
<br /> \/\� v EL 54E'-o' REMAIN
<br /> EL ,J.,,--.2.."
<br /> . . ' . ' ' ' :v.,v,x..mv4.r.sy,,x/, ,,.,
<br /> /\ \\//. , ,\//j....,
<br /> ,\4„(/ ,/ ,,
<br /> REFERENCE DRAWINGS
<br /> SECTION n SECTION n SECTION rn
<br /> SCALE: 3/8"=1'-0” M450-01
<br /> SCALE: 3/8"=1'-O" M450-01 SCALE: 3/8"=1'-0” M450-01
<br /> �I r)I
<br /> FINISHED LMECFWJICAL ROOM
<br /> to CONSTRUCTION NOTES
<br /> „\<
<br /> %4 - ■■■■ •• . CRETE 1�14x12 ECCENTRIC REDUCER(FIAT ON BOTTOM)
<br /> •`, `� : OND REROUTE 6"CW LINE BELOW EXISTING 141PS.FIELD ROUTE
<br /> (E) 6"CW; - AS REQUIRED.
<br /> --_—_
<br /> g, T .e. �PROVIDE NEW 1-1/2"METAL GRATE FOR EXISTING 3'-0"x
<br /> .
<br /> l--)7
<br /> RERO"SUMP OPENING.
<br /> I
<br /> ®REROUTE EXISTNG STAINLESS STEEL SOLVENT LINES AS
<br /> 1 REQUIRED.
<br /> NOT USED.
<br /> t`E "CW • • *=1 ©CAP EXISTING NITROGEN UNE IN CEILING AND REMOVE PIPING
<br /> '` �r0 NP 20.0 CORE DRILL FOR 14"HPS
<br /> ,1 ®PROVIDE 1-1/2"BALL VALVE LOW POINT DRAIN
<br /> 'NO,
<br /> ROLL 90'12"HPS ELBOW TO MAKE OFFSET CONNECTION.
<br /> © ,-- -COLUMN FIELD VERIFY EXACT OFFSET.
<br /> BEYOND
<br /> ,. ,. \/.//i�/j
<br /> SECTION
<br /> SCALE: 3/8"=1'-0" M450-01
<br /> ISSUED FOR PERMIT ANOFFMAN
<br /> 2L12.
<br /> ERS
<br /> 08 1601 Path Avenue,Sults 900'Seattle,WA 98101
<br /> �}(/ LL eh TA6 t3.1H1T I Ta 1088343TT8
<br /> wlhnmm"
<br /> . - Lamm —leewat w+
<br /> S
<br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
<br /> SYM PENSION BY APPROVED DATE SYM REVISION BY ARROW) DATE EL SO ACCEPTABILITY R.LEHNER 08.22.12 STEAM UPGRADES SECTIONS 11578401 ORIG 08.22.12 8
<br /> URIC SITE-VAULT"F"TO 45-003-STEAM UPGRADES 11578401 CB/MS MS 08.22.12 G4,' 41t l'6' THIS DESIGN AND/OR LHELREU _a
<br /> -•RIO .... SPECIFICATION IS APPROVED a IPSEN 08.22.12 SHEET 1N
<br /> BOE/NG® APPROVED BY DEPT. DATE CEII"EE" 08.22.72 TITLE SITE -VAULT"F"TO 45-003 STEAM UPGRADES M556-O I ft/7----(-- Iu
<br /> g)i.._
<br /> CHECKED
<br /> 4-........--_::, M.SOTURA 08.22.12 -
<br /> t,p .. , i. APPROVED BUILDING 45-003 JOB N0 11578401 °°M�"
<br /> imvAL VS'‘ APPROVED MECHANICAL MASTER EVERETT, WA DWG NO. 45-003-M556-01
<br />
|