Laserfiche WebLink
c. <br /> 4'-0" <br /> 1'-8" LEGEND <br /> STL EMBED M <br /> I S578-01 PS-# PIPE SUPPORT/ANCHOR <br /> SEE(\ <br /> M578-2 <br /> EXIST. 16" FIRE IN SPLIT _ <br /> SLEEVE THRU TUNNEL SEE �1 <br /> CML DRAWING C551-03 FUTURE 16"FW <br /> FOR INSTALLATION DETAILS <br /> ii <br /> _ TIE-IN LOCATION <br /> 1 <br /> —Z M - <br /> 16" HPS W/ II i♦r�V��♦ 1K)-',/,/,/,.1 <br /> 4-1/2° INSUL �-,'`♦! <br /> ®� ;2 'r'�%,%;';',; GENERAL NOTES <br /> o / 4-I • 1. UNLESS OTHERWISE NOTED, 16"HPS SHALL HAVE <br /> i LiTimilinallilli:N:14. <br /> ii ,' ,' * 4-1/2" FIBERGLASS INSULATION IN TUNNEL SECTIONS, <br /> N i,�';';';',i AND 6" FOAMGLASS INSULATION IN VAULTS. <br /> Fv , , , 4 P 'EXHAUST FAN (EF) SCHEDULE I'' ' ' ' ' ' 2. FUTURE LINES (16"WATER ARE DESIGNED BY OTHERS <br /> AND SHOWN FOR COORDINATION ONLY. <br /> EXHAUST FAN SECTION 1 <br /> NUMBER LOCATION EXTERNAL <br /> (ROOM NO.) BASIS OF DESIGN CFM STATIC PRESS. APPROX. DRIVE RK AREA SERVED <br /> BHP MOTOR VFD OPER WT. REMARKS MINIMUM WALKWAY <br /> ( <br /> INCHES WG RPM SIDE HP VOLTS PH HZ LBS) CLEARANCE AT THISLOCATION <br /> EF-1 TRENCH LID TUNNEL GREENHECK CUBE-300HP 6200 1.5 835 BELT 2.78 3 460 3 60 NO 223 1,2 <br /> TUNNEL SECTION n <br /> SCALE: 1/2"=1' M5xxx <br /> 1. EXHAUST FAN SHALL OPERATE CONTINUOUSLY AT LOW SPEED, AND SHALL OPERATE AT HIGH SPEED UPON ACTIVATION OF TUNNEL LIGHTS. <br /> 2. PROVIDE WITH 2-SPEED, 2 WINDING 1725/1140 RPM MOTOR <br /> 4'-0" <br /> 3'-6" <br /> FACTORY WIREDSTL EMBED�=-1 <br /> TO DISCONNECT S578-01 REFERENCE DRAWINGS <br /> Rim:71' <br /> tFi IFM ;_ . <br /> II 111_�' <br /> WIRING BY .-1, 1 q► <br /> ELECTRICAL <br /> Ir <br /> :! .!CONTRACTOR ��. I HSS 4x4x1/4" " 'b PS-2 ♦♦♦ <br /> I_ 'EiliI a TYP ®pm is 11/4 TrP (2) <br /> $ 2 l� 1/4 PLCS '1 SINGLE <br /> CONSTRUCTION NOTES <br /> Oor 1 B-ANEL S <br /> TYP (2) D> MITER STRUCT STL TOP BEAM AT CONC CHAMFER EMBED <br /> w PLCS 1 4F 1 F PLCSB 409 EVERY PLATE,AS REQUIRED FOR PS-2 SUPPORT INSTALLATION, <br /> 0. 8'-O"O.C. TIP ALL PS-2 PIPE SUPPORT LOCATIONS. <br /> TRENCH LID <br /> HSS 4x4x1/4", 38" <br /> ill 4 <br /> LG, TYP (2) PLCS <br /> 2. CONDENSATE PIPING SHALL BE INSTALLED WITH A <br /> " tillii e MINIMUM 1" FIBERGLASS INSULATION FOR <br /> 1/4� PERSONAL PROTECTION UNLESS NOTED OTHERWISE. <br /> 1. DAMPER <br /> 30" 3. DO NOT POCKET FLASH VENT PIPING. <br /> 32.5" I 9x9x3/8" BASE ® FLOOR SLOPES PER CML DRAWINGS, Cxxx-5 <br /> PLATE, SIM <br /> QSECURE WITH 3/16"WELD (EA SIDE OF CHANNEL <br /> M578-05 BRACKET) TO EMBED PLATE, OR WITH MINIMUM (4) <br /> 1/2" STAINLESS STEEL ANCHORS EMBED OF 3-1/2") <br /> AND EPDXY ANCHOR SYSTEM (IF NO EMBED IS <br /> AVAILABLE). <br /> EXHAUST FAN DETAIL ric". TUNNEL GUIDE SUPPORT DETAILSn <br /> SCALE: NTS M578-01 SCALE: 1/2"=1' Mxxx <br /> ISSUED FOR PERMIT �NOFFIVIAN <br /> GINEERS <br /> 08 2L.1. <br /> 1601 FiM Avenue,Suits9001 Seattle,WO.96101 <br /> L2 L 0662107171Na 206.62.3776 <br /> • <br /> SYM PENSION 81, APPROVED DATE SW REVISIDN 8Y APPROVED DATE DRAWN DATE SURTIIu CURRENT REVISION SYMBOL DALE ci <br /> _ gL so ACCEPTABILITY G.ROUTH 08.22.12 SECTIONS AND DETAILS 11578401 ORIG 08.22.12 <br /> ORIG SIZE-VAULT"F"TO 45-003-STEAM UPGRADES 11578401 CEI MS MS 08.22.12 , T(� THIS DESIGN MND/OR S.HELKLO <br /> / SPECIFMATION IS APPROVED M.SOTURA 08.22.12 STEEDS <br /> ® y EN`'INWI TITLE SITE-VAULT"F"TO 45-003 - STEAM UPGRADES <br /> AS FA APPROVED DEPT. DATE GEI 08.22.,2 M578-01 i9-' ,oc! <br /> g. 1....__ <br /> t/� APPROVE <br /> 08.22.12 08.22.12 <br /> tis.. APPROVED SITE 45 YD De No 11578401 id <br /> F <br /> VIINUL 1$`;' APPROVED MECHANICAL MASTER EVERETT, WA DWG NO. 45-YD-M578-01 <br />