My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-08 2019-07-15
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-08
>
3003 W CASINO RD BLDG 45-08 2019-07-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2019 3:35:28 PM
Creation date
7/15/2019 3:35:08 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-08
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
129
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND & SYMBOLS <br /> 1. FOR PAID SYMBOLS&NOTES SEE SHEETS M310&M311. <br /> LEVEL LEVEL <br /> LEVEL <br /> ,, HIGH LEAK OPND CLSD LEVEL HIGH man <br /> CLSD <br /> =m =EN =mg man <br /> LIT-511 ® HV-510 LIT-521 HV-520 <br /> ; CONSTRUCTION NOTES: <br /> — — q _ 6 _ _ _ _ q q q q q <br /> 1— �EXISTING 2,000 GAL DOUBLE-WALLED TANK SHALL BE RE-USED TO <br /> O O O O p STORE SODIUM&SULFITE. REMOVE ALL SULFURIC ACID FROM TANK <br /> AND ASSOCIATED SULFURIC ACID CHEMICAL TUBING.CONTRACTOR <br /> SHALL THOROUGHLY CLEAN TANK PER MANUFACTURER'S <br /> °' A , . n A. RECOMMENDATIONS. TANK SHALL BE DRIED PER MANUFACTURER'S <br /> ---}.- 4 \ RECOMMENDATIONS PRIOR TO CHEMICAL FILL CONTRACTOR SPALL <br /> fir, — <br /> PROTECT TANK DURING DEMO AND CONSTRUCTION TO PREVENT ANY <br /> DAMAGES THAT MAY IMPACT THE INTEGRITY OF THE TANK. <br /> / ' <br /> \\\ i CUT&CAP SULFURIC ACID FILL UNE ON WEST EXTERIOR WALL <br /> j <br /> p CAP CHEMICAL TUBING DOWNSTREAM OF WYE. REMOVE SULFURIC <br /> i ACID TUBING FROM STORAGE TANK EFFLUENT TO THE BUILDING'S <br /> i i � i SOUTHWEST CORNER. <br /> s <br /> % / , / ®REMOVE DESSICANT DRYER ON VENT. <br /> i i i r AS T--552U,REN OVERFILL U 1:>.,REMOVE THE 1,000 GAL SINGLE �TANK CURRENTLY LAMED <br /> 11:::>.CUT de CAP SODIUM BISULF1TE FILL UNE AT INTERIOR <br /> WEST <br /> ,i -- i WALL. SODIUM <br /> CUT&CAP ISULFITE UNE DOWNSTREAM OF <br /> IN-520. CONNECTIONS WILL BE REQUIRED FROM EXISTING SODIUM <br /> BISULF1TE FILL LINE AND SODIUM BISULFITE TANK EFFLUENT TUBING <br /> S i i - TO RE-USED 2,000 GAL DOUBLE-WALL TANK. <br /> THE FOLLOWING INSTRUMENTS WILL BE RE-USED.REMOVE AND <br /> / .i i i O STORE UNTIL RE-INSTAUATION: <br /> LE-521(INSTRUMENT) <br /> ,� / / , UT-521(TRANSMITTER) <br /> ,.. i HV-520 AND ASSOCIATED UNITSWITCHES <br /> i <br /> HV-521 <br /> SEE SPECIFICATION SECTION 40 90 10 APPENDIX B- <br /> i INSTRUMENT LIST FOR RE-USED DEVICE ALLOCATION <br /> / / '� / 8. SEE DEMO ATTACHMENTS.AT A MINIMUM ALL CHEMICAL TANKS, <br /> i i EQUIPMENT,PIPING,TUBING,AND APPURTANCES Stall BE DRAINED <br /> i - i " AND TRIPLE RINSED PRIOR TO REMOVAL OR RE-USE.CONFIRM W/A <br /> j LITMUS PAPER TEST THAT TANKS,PUMPS,PoPiNG,TUBING,EF AL <br /> ARE AT A NEUTRAL pH. <br /> i <br /> i <br /> i i i , i <br /> i <br /> : - , � <br /> r �� risrii� yfr Mr - - „....; , <br /> VENT W/DESSICANT AIR LDRYER(THROUGH ROOF -, i /10,11f <br /> .� 2 0i OVERT OW _ i , ��� <br /> 411 ' e.N II11°t iT_5ipZSO r ' 0 ' <br /> 2000 GAL 510 i � 0� '' i , 0t= HV-510 ' �� <br /> FILL UNE 1]-141— UT LE HV-511 4 HU.LINE 1]- 141- UT LE j HV-521 <br /> HV-S13 Sli 511 _ ,I - FN-523 521 521 <br /> HV-512 \LAN !�// HV-522 �+ •�/I�//,I�//I.�/I,�i% .,I <br /> �' �5� 4 y ��" TRENCH `�' X521\ TRENCHir <br /> I, \ TRENCHDRAIN �,� DRAIN <br /> �� • <br /> TO P-521TRENCH TRENCH B 1--Std-55-52iDNq.No.M324 > <br /> DRAIN wA!'#J <br /> DRAIN <br /> 4#(11ril—. <br /> O T-520 <br /> T-510 <br /> SULFURIC ACID SODIUM METASULFITE STORAGE TANK <br /> STORAGE TANK <br /> 100%DESIGN-ISSUED FOR CONSTRUCTION REMOVAL CCS Stantec <br /> GYM REVISION RI APPROVED RATE GYM MASON APPROVED ERIE DRAWN GATE SUBNRE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY SERGIVENKO 3.20.18 <br /> A IMP-ISSUED FOR CONSTRUCTION-RECORD 10011818 URS TORRE 11.14.12 s 0,1.44.,,I!, NDS DESIGN AND/OR CHECKED P&ID-CHEMICAL SYSTEMS $ <br /> B YAYTP-REMOVAL BEAU WFAxtEY 1205.18 L ® A.. 4: a• SPECIFIC/00N IS APPROVED , 3.20.18 1111E WASTEWATER TREATMENT PLANT SHEETBOE�iYG • r'Y APPROVED NY DEPT. DATE WFAKIEY 3.20.18 M320R Q jJ <br /> ; „` OHLNSON 3.20.18 BUILDING 45-08 008 NO. <br /> oA APPROVED <br /> s O+ WEAKLEY 3.20.18 <br /> °°AONAt HARRIS° 3.20.18 MECHANICAL MASTER EVERETT,WA DWG"o' 45-08-M320R , <br />
The URL can be used to link to this page
Your browser does not support the video tag.