My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-08 2019-07-15
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-08
>
3003 W CASINO RD BLDG 45-08 2019-07-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2019 3:35:28 PM
Creation date
7/15/2019 3:35:08 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-08
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
129
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPLIT DX HEAT PUMP SCHEDULECI <br /> SIZE RA INLET SUPPLY OUTLET FAN AMP O COMPR AMP MOTOR COOLING CAPACITY. HEATING CAPACETY� REFRIGERANT/PIPES BASIS OF DESIGN <br /> MARK BOEING EQUIPMENT NO. LOCATION TYPE (IN K IN X 512E SIZE CAN ESP(IN WG) DRIVE TYPE SEER MCA MOP WEIGHT NOTES GENERAL NOTES <br /> IN) (IN x IN.) (IN x IN.) 230/ 0 230V ,0,T <br /> /PH EAT(DB/WB) TOT BTU/HR EAT(06/008) TOT BTU/HR TYPE U0 SIZE YAP SIZE MANUFACTURER MODEL <br /> HP-IA INDOOR CEILING MOUNT 56X29%10 27 X 9 28 X 9 1100 0.4 DIRECT 13.8 2.8 3.5 208/1 BOE/67F 42000 70E/60F 45000 R-4104 3/8" 5/8" 95 MRSUBISHI PEAR AD A42HA 1) <br /> G <br /> HP-TB OUTSIDE WALL MOUNT 38014038 -- -- 3530 0.1 DIRECT -- 0.75 20 26 40 208/1 95/75 -- 47 -- R-4104 3/8" 5/B" 260 MITSUBISHI PUZ A42 NHA3(-85) 1) 1. SHESHEET M PROCESS EQUIPMENT SCHEDULES ME PROVIDED ON <br /> M340. <br /> i HEATING CAPACITY BASED ON 17F DB 15F W8 <br /> • COOUNG CAPACITY BASED ON 9508/75W9 AMBIENT CONDITONS <br /> 1)RECESSED MOUNT INDOOR UNIT WITH REFRIGERANT AND CONDENSATE PIPING PER MFR,RECOMMENDATION.PROVIDE WITH MFR.24/7 CONTOL/TSTAT,LOW A)ABENT CONTROLS,DEFROST CYCLE,LOW/HIGH HEAD PRESSURE CONTROL,AUX AIR ECONOMIZER TO ENGAGE AS FIRST STAGE OF COOUNG. CONSTRUCTION NOTES: <br /> 2)PROVIDE ALUMINUM BRACKET/SS NUTS&BOLTS MID MOUNT OUTDOOR UNIT AT BET ABOVE GRADE WITH WALL BRACKET TO ALLOW 619 CLEAR AIR FLOW INTAKE CLEARANCE BETWEEN WALL MID UNIT MID MFR.REQUIRED CLEARANCES ON ALL SIDES. FIXED TEXT STILE TO MATCH. <br /> HEAT RECOVERY UNIT SCHEDULE [ - REBALANCE EXISTING HVAC SYSTEM TO ACCOUNT <br /> SUPPLY FAN RETURN EXHAUST FAN GAS FURNACE HEAT EXCHANGER PERFORMANCE(WINTER) SINGLE BASIS OF DESIGN FOR ADDITIONAL EXHAUST FAN ADDED. <br /> POINT WEIGHT <br /> MARK EQUBOEINGIPMENT NO LOCATION TYPEESP(IN DRIVE FAN ESP(IN DRIVE FAN MBH EFF H/ INLET GAS OSA EAT OSA LAT TOT MBH RA EAT RACA MOP NOTES O NEW FUME EXHAUST FAN AND STACK ADDED TO <br /> CFM FAN HP VOLVOLTAGE/ (LB) MANUFACTURER MODEL STSIGI <br /> WG) TYPE RPM CFM FAN HP MATERIAL WG) TYPE RPM INPUT SEER TEMP PRESS (DBAWB) (DB/WB) INPUT • (DB/WB) (DBMlB) PH <br /> HVAC-1 EQ PLTFRM SEMI-CUSTOM 9700 1.5 BELT 10 1824 8750 1 BELT 10 1581 800 80 50 7"WC 17 46.1 800 70 44 304 SS 460/3 33 40 12000 INNOVENT ERU 1.2.3 cm ® CHANGED THE WORD'MEZZANINE"TO <br /> NOTES: 0 <br /> 2 <br /> 0 0 0 ACTIVI YfM PLATFORM'.NO CONSTRUCTION <br /> FIXED SHEET NUMBER.NO CONSTRUCTION <br /> 1)PROVIDE DOUBLE WALL GALVANIZED STEEL CONSTRUCTION,OUTSIDE AIR,EXHAUST AIR SHUTOFF DAMPERS,RECIRC DAMPER,DAMPER ACTUATORS.MERV 8 PREFILTER AND MERV 14 CARBON FILTERS ON EXHAUST,MERV 8 PREFILTERS AND MERV 13 FILTERS ON SUPPLY,6"HIGH STEEL BASE FRAME W/LIFTING EYES. ACTMTY <br /> 2)SS DRIP PAN BELOW HEAT EXCHANGER AND BELOW FURNACE.SS FURNACE HEAT EXCHANGER,FULLY MODULATING FURNACE CONTROLS WITH CONCENTRIC 2-6"OSA INTAKE/6'GAS VENT KITS,UNIT MOUNTED 0ISCONNECT••FOR SF AND EF.INTERNAL FAN SPRING ISOLATION CONNECTION/DISCONNECT.SEPARATE 120 V DISCONNECT,CIRCUIT AND LIGHT <br /> SWITCHES IN FAN COMPARTMENTS.MFR PROVIDED ELECTRONIC DEFROST DAMPERS/CONTROLS. <br /> 3) PROVIDE INTERNAL FAN SPRING ISOLATION,TEFC PREMIUM EFFICIENCY FAN MOTORS,SINGLE POINT 480 V ELECTRICAL CONNECTION/DISCONNECT,SEPARATE 120 V DISCONNECT,CIRCUIT AND LIGHT SWITCHES IN FAN COMPARTMENTS. <br /> IVW.-M/VW .. <br /> 4) REBALANCE SUPPLY AND RETURN FLOW RATES <br /> 2 ■ FANS PLUMBING FIXTURE SCHEDULE <br /> BOEING ■ INLET OVERALL MOTOR MOTOR BASIS OF DESIGN <br /> MARK EQUIPMENT AREA LOCATION PE SIZE SIZE CFM TSP(IN DRIVE TYPE FAN RPM FAN BHP MAX MOTOR HP VOLTAGE/ WEIGHT - NOTES <br /> NO. SERVED . (IN x IN.) (IN x IN.) WG) (WATTS) SONES RPM (WATTS) PH <br /> MANUFACTURER MODEL MARK FIXTURE DESCRIPTION ACCESSORIES DESCRIPTION NOTES <br /> VENT CW HW PW AIR ADA INST <br /> EQUIPMENT 150 O IW CONN <br /> SF-1 MCC PLATFORM CA.INT X1 4. 40 0.•5 xI•.0 1 ILI W. 14.• 5 1 1/: 1211 40 •• N' • 1 <br /> EF-1 S ROOF HIGH PLUME 13'DIA 40x36x127 2000 1.50 DUAL BELT 2461 1.3 - 1725 2 460/3 400 GREENHECK EL ORM 2 3 P-1 SINGLE SINK-SS SELF RIMMING MIXING FAUCET 1-1/2 - 1/2 1/2 YES <br /> - -12-10-II-MV <br /> © P-2 EMERGENCY SHOWER/EYEWASH W/1"X1")(1'THERMO MIXING - - 1 1 YES 1 <br /> • <br /> P-3 SINGLE SS COUNTER/SINK DUAL FAUCETS/VB 1-1/2 - 1/2 1/2 1/2 NO 3 <br /> NOTES: • <br /> P-4 LOW VOLUME DUPLEX AIR OUTLET BOEING STANDARD QUICK CONN 211/21 NO 4 <br /> P:O • M .,F:F••: • . •-.G ••T•N. . • 8 D ' •:• B. •_ x : , • • D O.T••LL • I •L '0 T. -..0 - <br /> An <br /> 2)COMPLET WI H MILL DUTY TEFC NEMA PREMIUM EF ICIENT MOTOR.ENTI-E NI COAT D WIT " ':COA"O•APPROVED EQUAL.316 SS SHAFT.SPRING ISOLATOR,AIRFLOW MONITORING STA ION"SUR-AIRE"OR EQUAL.WIND BAND AND SELF SUPPORTED P.O HIGH VOLUME DUPLEX AIR OUTLET BOEING STANDARD QUICK CONN 2(3/4") NO 2 <br /> STACK TO DISCHARGE A MINIMUM OF 10-0"ABOVE ROOF WITHOUT GUY WIRES,L(1)LIFE OF 80,000 HOURS BEARINGS,WEATHERHOOD FOR MOTOR. p-6 PRESSURE WASHER(RELOCATED) WALL EXTENSION TO WARM SIDE - - . 1 NO <br /> 3)CONTRACTOR/FIELD SUPPLY ROOF EQUIPMENT RAILS.ELECTRICAL DiSCONNECT BY DIV 26. GRILLE SCHEDULE <br /> ■O <br /> HB-1 DOMESTIC WATER HOSE BIBB- FREEZE PROOF EXTENSION - - 3/4" - NO <br /> HB-2 PROCESS WATER HOSE BIBB- FREEZE PROOF EXTENSION - - . 1-1/4" NO <br /> TYPE CAPACITY BASIS OF DESIGN HB-3 PROCESS WATER HOSE BIBB- INDOOR HOSE VALVE - - - 3/4" NO <br /> MARK NOM FACE FINISH/ BORDER NECK SIZE DUCT MAX FLOW MAX SP(IN MAX NECK NOTES <br /> MAX NC[2] MANUFACTURER MODEL 1.ADA COMPLIANT.PROVIDE WITH MFR SELECTED TEMPERING VALVE TO SERVE EYEWASH AND SHOWER. <br /> DESCRIPTION MATERIAL SIZE(IN) COLOR TYPE (IN) CONN(IN) (CFM) WG) VEL(IN) <br /> CD1 CEILING DIFFUSER STEEL 24 X 24 WHITE [1] 10 10 550 0.1 900 29 TITUS MCD 2.PROVIDE DIXON MODEL SCVM-R FLOW SENSOR VALVE AND DYNACON 001355973 HOSE COUPLER ON EACH OUTLET <br /> SR-1 SUPPLY REGISTER ALUM - WHITE FRAME # 0.1 550 30 TITUS 300FL <br /> 3.SINK AND INTEGRAL SS COUNTER WITH SS LEGS AND 12 HIGH BACKSPLASH <br /> RG-1 RETURN GRILLE ALUM WHITE FRAME 1 # • 0.1 500 20 TITUS 50FF 4.PROVIDE DIXON MODEL SCVM-8 FLOW SENSOR VALVE AND DYNACON 001355973 HOSE COUPLER ON EACH OUTLET <br /> RG-2 RETURN GRILLE ALUM WHITE FRAME # • 0.1 500 22 TITUS 350ZFL DAMPER SCHEDULE <br /> EG-1 EXHAUST GRILLE ALUM WHITE FRAME # 0.1 500 22 TITUS 3502FL <br /> NOTES: OVERALL FACE SP BASIS OF DESIGN <br /> DEPTH NUMBER OF MAX DROP DAMPER DAMPER PROVIDE <br /> MARK^ OTY SERVES LOCATED DAMPER BLADES SIZE VEL NOTES <br /> ' AS SHOWN ON DRAWINGS (IN X IN.) (IN) SECTIONS CFM (FPM) (G'1 MATERIAL TYPE FIRESTAT MANUFACTURER MODEL <br /> # SAME SIZE AS GRILLE. D-1 1 HP-1 RELIEF OFFICE/CONTROL RM PARALLEL BLADE 36512 4 1 11W 367 0.1 GALV STEEL SMOKE/FIRE YES 1 <br /> 5-2 1 SF-1 MAKEUP MCC RM PARALLEL BLADE 24x18 4 1 350 117 0.1 GALV STEEL SMOKE/FIRE YES 1 <br /> D-3 1 SF-1 RELEIF MCC RM PARALLEL BLADE 20x16 4 1 350 160 0.1 GALV STEEL SMOKEiFIRE YES I <br /> 1.PROVIDE DIFFUSERS WITH BORDER STYLES THAT ARE COMPATIBLE WITH ADJACENT CEILING SYSTEM.REFER TO ARCHITECTURAL PLANS. ' <br /> HP-1 - <br /> D4 1 ECONOMIZER OFFICE CEILING PARALLEL BLADE 36X10 4 1 1100 367 0.1 GALV STEEL CONTROL NO 1 <br /> 2.NC BASED ON OCTAVE BANDS 2-7 SOUND POWER LEVELS MINUS A ROOM ABSORPTION OF 10 DB,MEASURED PER ASHRAE 70-91. <br /> HP-1 <br /> D5 1 ECONOMIZER OFFICE CEILING PARALLEL BLADE 36X10 4 1 1100 367 0.1 GALV STEEL CONTROL NO 1 <br /> WATER HEATER SCHEDULE <4 <br /> D5 I HP-1 RELIEF lo,. OFFICE CEILING PARALLEL BLADE 38012 4 1 -1100 367 0.1 GALV STEEL BACKDRAFT NO 1 <br /> RECOVERY WIDTH/ <br /> GAS GAS ELECTRICAL BASIS OF DESIGN <br /> MARK BOEING SERVICE TYPE STORAGE CAPACITIES(GPU)AT DIAMETER HEIGHT INPUT OUTPUT WEIGHT NOTES 5-7 1 SF-1 SUPPLY EQUIPMENT PLATFO- PARALLEL BLADE 20X20 4 1 1100 126 0.1 GALV STEEL BACKDRAFT NO • <br /> EQUIPMENT NO. (GAL) 100 DEG°F TEMP (INCH) (INCH) TOTAL AMP V/PH/(60HZ) MFR MODEL <br /> RISE MBH MBH NO. ■ <br /> ■ <br /> WH-1 DOMESTIC HW TANK 50 80 22 71 76 69 3 120/1 A.O.SMITH BTX-80 625 [11 NOTES: •LIST MFR SELECTION IN AS-BUILT DOCUMENTS. _ _ <br /> 1)PROVIDE U.L.LISTED SMOKE/FIRE DAMPER WITH 1200/1 PH ELECTRIC ACTUATOR(OUTSIDE AIR STREAM)FOR EACH DAMPER SECTION FURNISHED BY MFR. <br /> NOTES: /L <br /> 1,PROVIDE MFR RECOMMENDED CONCENTRIC VENT KIT,FLUE DRAIN/TRAP,AMTROL XTROL ST-12 EXPANSION TANK ON CW INLET,S5 DRIP PAN AND SEISMIC STRAP TO WALL. <br /> ELECTRIC�•• LJ EAT E 17 SCHEDULE <br /> PUMP SCHEDULE fN li F1 WIDTH/ R ELECTRICAL BASIS OF DESIGN <br /> MARK BOEING LOCATION TYPE MOUNTING DEPTH HEIGHT NOTES <br /> EQUIPMENT NO. (INCH) (INCH) <br /> TOTAL KW V/PH/(60HZ) MANUFACTURER MODEL NO. <br /> B ELECTRICAL BASIS OF DESIGN <br /> BOEING UH•1 MAIN ENTRY UNIT WALU CLG 14//.5 16 5 460/3 QMARK MUH [1] <br /> MARK EQUIP No Q()CATION TYPE MOUNTING GPM HEAD(FT) TOTAL NOTES <br /> WATTS V/PH/(60HZ) MANUFACTURER MODEL NO. UH-2 FIRE SPRINKLER UNIT WALU CLG 14/7.5 16 5 460/3 OMARK MUH [11 <br /> EOUIPMEN BELL& UH-3 FIRE SPRINKLER UNIT WALL/CLG 14/7.5 16 5 460/3 ()MARK MUH [1] <br /> CP-1 PLATFORM IN LINE HUNG 5 10 120 120/1 GOSSETT NBF 185 111 NOTES: <br /> 1.PROVIDE WITH INTEGRAL THERMOSTAT,WALL BRACKET,OVERLOAD PROTECTION,INTERNAL RELAY&DISCONNECT. <br /> NOTES: <br /> 1.PROVIDE ALL BRONZE CONSTRUCTION FOR DOMESTIC WATER WITH TSTAT,24 HR TIMER,OVERLOAD PROTECTION&RELAY. <br /> 100% DESIGN - ISSUED FOR CONSTRUCTION ® Stantec <br /> SY7.1 REVISION 8Y APPRO/FD PATE SYM ROOM IW APPROVED 617E DRAWN DATE SUBTITLE CURRENT REASON SYYBOL DATE <br /> ��NAl ACCEPTABILITY SERCIYENKO 3.20.18 <br /> ,1 lx*5' TRS DESIGN AND/OR MECHANICAL EQUIPMENT SCHEDULE 3.20.18 <br /> A WWTP-ISSUED FOR CONSTRUCTION-RECORD 10011818 URS HAMILTON 11.14.12 ,v a SPEOFIGTION G APPROVED <br /> WEAKLEY 3.20.18 SHEET <br /> B HElP-MODIFICATIONS MWH REAGAN 12.05.161?:.,.___Arkt7AEZAW e` t APPROVED!D- SEPT. DATE REAGPN 3.20.18 B M2 <br /> ' CHOKED <br /> ® y 11$. o /REHOAN TITLE WASTE WATER TREATMENT PLANT a a <br /> �- JOHNSON 3.20.18 1 <br /> p'0• e4Te458 EAKLEY' 3.20.18 BUILDING 4'-08 NO. 5 COLLIP�. <br /> °97ouw1,s� HARRIS 3.20.18 MECHANICAL MASTER © EVERETT, WA oxo No. 45M2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.