Laserfiche WebLink
CONSTRUCTION NOTES <br /> REMOVE EXISTING P-532 AT PUMP CONNECTION POINTS <br /> is PROTECT EXISTING CHEMICAL SKID TUBING,VALVES, <br /> PRESS PRESS INSTRUMENTS,AND APPURTENANCES DURING DEMO AND <br /> OPND SPEED AUTO START RUN FAULT OPND HIGH OPND SPEED AUTO START RUN FAULT OPND HIGH CONSTRUCTION. THIS PUMP SHALL BE USED FOR SODIUM <br /> Eri \ '� ` BISULFITE.REMOVE EXISTING MOTOR FROM PUMP.MOTOR WILL <br /> �SC\ /V YI�XC�Xi XA ` 322 11-3A1-- EN �SC�YI�XC�XI�XA ` m BE RE-USED FOR NEW CAUSTIC SODA PUMP. <br /> 1 YE' M-531 ME PSH-531 = M-532 IT ZIE <br /> 1-, >,I I I I I I I I I f 1 INSTALL BLIND FIANCE AND GASKET. <br /> I 11 ' ' I 3. SEE DEMO ATTACHMENTS.AT A MINIMUM ALL CHEMICAL TANKS, <br /> 'O O O O O O OO p 9 O 9 9 9 'O p EQUIPMENT,PIPING,TUBING,AND APPURTANCES SHALL BE DRAINED <br /> ' i I AND TRIPLE RINSED PRIOR TO REMOVAL OR RE-USE.CONFIRM W/A <br /> O :171,_6— — — — _ —0 —a- — "Q— II—-a — UTMUS PAPER TEST THAT TANKS,PUMPS,PIPING,TUBING,ET AL <br /> O —'O —0 ARE AT A NEUTRAL pH. <br /> a A O O O O 6 A Q O O O O 6 o p <br /> 1---0-1-0---d---0--11---0-1 o o d to o� <br /> — O— -,— — — ---0 — — — I — <br /> R IO -- \(;1-:''/RO / 'I <br /> I <br /> I / \ 1 'I i / \ I i <br /> YS O I YS O <br /> 531 I HOA I ,. 532 HOA , i <br /> o <br /> HS <br /> 1 , OS 0 - <br /> 531 m 0 <br /> 531 uy, 532 <br /> — FAULT I- FAULT <br /> \ \ - \ \ I <br /> i <br /> c I <br /> I I <br /> i <br /> I - <br /> I I/2'-CAU-SS-533A > Ng.No.M3T3 > <br /> i - I _ <br /> I - I 2 <br /> i I TO <br /> CONCENTRATION TANK <br /> I i i I 1/2'-CAU-SS-534 > Ng.No.M377 > <br /> 1 1 - <br /> i I� I - i <br /> 1_.__ I / _ <br /> i <br /> 1 ' ® ® 1 <br /> i Ilia PI — - 1 <br /> 537 <br /> 43' ZSD - ZSO <br /> ,:11°) <br /> 50 1 <br /> ZSO 3 <br /> 531 531B 328 1 <br /> y 1V ES <br /> 0 V <br /> •I....,� 0 • HV-5328 <br /> '�- MJ-S3TB I `♦ a <br /> I ‘111- <br /> 1 <br /> 1 -. —�� _i� T °I$SII—' <br /> OAIV-532A <br /> FM-531Ay, <br /> IF� P-531 T y — <br /> � <br /> TRENCH r---- <br /> I <br /> FROM 1-530 FROM T-530 1 <br /> > Dxg.No.M321> I II- > on.No.M321>—i I—► TRENCH <br /> _ DRAIN <br /> CAUSTIC SODA SKID(BY SUPPLIER) <br /> P-531 P-532 <br /> CAUSTIC SODA PUMP CAUSTIC SODA PUMP <br /> 100% DESIGN-ISSUED FOR CONSTRUCTION REMOVAL 5 Stantec <br /> SYM REASON BY APPROVED DATE STM WIDOW BY APPROVED DATE ACCEPTABILITY SERGIVENKO 3.20.18 <br /> DRAWN E SUBDUE CURRENT REVISION SYMBOL C DATE <br /> A WATP-ISSUED FOR CONSTRUCTION-RECORD 10011818 ABS TORRE 11.14.12 TT or•4iii- DAS DESIGN AND/OR P&ID-CHEMICAL SYSTEMS 3. 18 <br /> R 4",!;,. SPECIRCATION 0 PPPRUO WEAKIET 3.20.18 SHEET <br /> B ECN94-ISSUED FOR CONSTRUCTION 10011818 URS MOCKOS 03.22.13 . "ED BttE WASTEWATER TREATMENT PLANT <br /> BOE/A/6 _ r� APPROVED BY DEPT. DATE CHECKED 3.20.18 M325R ��o <br /> C WWTP-REMOVALMWH WEAKLEY 12.05.16 ♦ JOHNSONVE3.20.18 J <br /> ,y lam"" 3.20,8 BUILDING 45-08 NO. «PND= <br /> �.AON"T HAARR APPROVED 3.20.18 MECHANICAL MASTER EVERETT,WA DWG AC. 45-08-M325R <br />