My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1200 INDUSTRY ST PROLOGIS 2019-07-24
>
Address Records
>
INDUSTRY ST
>
1200
>
PROLOGIS
>
1200 INDUSTRY ST PROLOGIS 2019-07-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/24/2019 7:52:49 AM
Creation date
7/24/2019 7:52:47 AM
Metadata
Fields
Template:
Address Document
Street Name
INDUSTRY ST
Street Number
1200
Tenant Name
PROLOGIS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C - <br /> PROJHTK 19-0053 0:1P62 PROLOGS General Notes: <br /> January 22 2019 1310 IN7L5TRy STREET-BLD F <br /> DRA:M64GK 81633067 EVERETT.WA 98203 <br /> 1. Design is based on a 110 mph, 3 second gust wind design per <br /> WIND LOAD 16.28 PSF IBC 2015 with State Amendments. Category II, Exposure C. <br /> WE' SPE 110 F.IPH CLE74T: ARCF4IE(,TURAL GRAPHICS,WC Seismic Design Category D. <br /> �t7DLUI.INS 2 0C2015 26551Nf13iNA1)oNALPK:W. 2. Caisson and Vertical Slob foundations ore based on a <br /> DESIGNER SR v�icria BFACHVA presumptivesoil bearing pressure minimum of 100 <br /> __ _ __._ ._ : per - <br /> safe aero <br /> psf foot of depth. Isolated lateral bearing footings subject <br /> to short-term lateral loads and not adverselyaffected bya <br /> SHAPE CENTROID TOTAL BASE ADJUSTED <br /> ff51 t47GHr WIDTH ' FACTOR HEIGHT AREA • FORCE 1:1011541 MOMENT CENTROID MOMENT 1/2" motion at grade are permitted to be designed using twice <br /> - --- ____ _ ____ the tabulated value of the corresponding soil class. <br /> SIGN 2.125 9.000 0.891 1.070 17.040 0.277 0.297 3. A soil report was not provided. Foundation analysis assumes-Soil <br /> SIGN 4.125 9.000 1.000 2.269 37.125 0.882 2812 2.658 3.015 2.934 Classification 5. Allowable bearing pressure should be verified <br /> SUBGRADE 0.500 0.250 0.000 0.882 3374 prior to placement of concrete. In the event that the stated <br /> OAH 6.250 requirements are not met and conditions appear deleterious, <br /> cease and secure excavation and immediately contact <br /> ODLUMINCALCLLATIONS co:::: RFEo=ort�r_TTsq ARCHITECTURAL GRAPHICS, INC. <br /> DESIGN OBLIQUE AVAILABLE COLUMN OBLIQUE 4. Foundation shall not be placed at the top of, or on the side of <br /> COLUMN COLUId4 LU:IN ` Lxz `raoDULus' LOAD FLEXURAL MITER LOAD a slope exceeding 3:1, or adjacent to a fill slope unless <br /> ITEM WIDTH DEPTH WALL COLUMN COLUMN MOM1ENr STRENGTH DISTANCE FACTOR LXJTY re-evaluated by a competent Professional Engineer. Do not <br /> «- » ----- ------ _�___ = _____ ___= place foundation in fill. <br /> P SIGN 1.900 0.135 0.3 0.42 0.297 0.74 7.896 1.456 0.526 5. Concrete shall be mixed to attain a minimum 28 day <br /> 1 T SIGN 3.000 3.000 0 174 2.5 1.97 2.136 4.53 0.472 compressive strength of 3000 psi. <br /> T SUBGRAOE 3.000 1.000 0.174 2s 1.97 2.456 4.53 0.542 6. Steel reinforcing bars shall conform to ASTM, A615, Grade 60 <br /> with deformations in accordance with ASTM A305. Welding of <br /> 0OLTCALCLILATIorS reinforcing bars is prohibited. <br /> ...d.,..«.., DB p1� 7. All voids between column base plate and foundation surface shall <br /> _ _ ..; . _e_. .. _ 1E_,•.._ _ ... be completely filled with high-strength, non-shrink rout. <br /> __ _ BOLT BOLTSr TENSIOW_ BOLT ALLO:N. � ALLO:NA BLE P Y9 <br /> RB:1 MOMENT SPA Ott RATE BOLT DAM. STRESS TENSION 8. Anchor bolts shall meet ASTM F1554 Grade 36. Exposed surfaces <br /> - =_ _ <br /> =___= ' - ._ shall be galvanized or coated to prevent corrosion. <br /> 3.""" support 9. All members shall be free from defects. Steel tube shall <br /> BASER 3.374 6.000 4.000 2456 0.625 19.100 5.860 <br /> meet ASTM A500 Grade B with a minimum yield strength of <br /> PIA TECALa.LATIONS 46000 psi. Steel Pipe up to 24 inch 0.D. shall meet ASTM A53 <br /> .....»«.... . . Grade B with a minimum yield strength of 35000 psi. Steel <br /> angle, channel and plate shall meet ASTM A36. <br /> RBA TENSION/ MOMENT MOMENT PLATE PLATE DATE MINIMUM 10. Steel welds shall be made with E70xx low hydrogen electrodes <br /> , BOLT ARM FLA TE WIDTH DEPTH 1HCK. THac. by persons qualified in accordance with AWS standards within the <br /> IBASEPL 2.456 2250 5.527 5.813 9.500 0.500 0.460 past two years. <br /> 11. All structural bolts shall conform to ASTM A325, and be zinc <br /> ANCHORBOLT FROJEC110N ANCHOR EMBEDMENT ANCHOR E!OLTMIN.IETGTH coated unless noted otherwise. When used with structural bolts, <br /> 3.625 7.819 12.000 heavy hex nuts shall conform to ASTM A563, and washers shall <br /> t conform to ASTM F436. Pretension all high strength bolts using <br /> AVERi1C1LSLA B the Turn-of-Nut method unless noted otherwise. <br /> MOMENT 2.456 FT-111. 12. The scope of this engineer does not include onsite observations. <br /> i .1FORCE 0.642 MP13. LINK Engineering will not be responsible for the safety on this <br /> REFERRENCEIBC1807.3.28.TABLE 1806.2 job site before, during or after installation of this structure. It <br /> ASSUME SQL CLASS#5 a.III it &G1 is the responsibility of the owners, contractors and installers to <br /> _ _FTCF <br /> PSF/FT __ ensure that the installation and erection of this structure is <br /> tATERALBEARWGI'RESSURE•PSF/ CEPTH 2)28.0 performed usingmethods that are in full compliance with OSHA <br /> S1 2555,• rgulations. P <br /> SLAB,DEPTHca) 3933 Pr. <br /> SLABMOTH(b) 4.000 Fr. 14. Any deviation from this design or from any part of this drawing, <br /> SLAB TI-0O(NENS 1.540 <br /> FT. including the General Notes, without prior written consent from <br /> AVERAGEI�GHr(h) 3.827 F1 LINK Engineering voids this drawing in its entirety. <br /> A=2.34'FOf1Lfl(S1.0) 1.752 15. The structure designed on this drawing is intended to be <br /> CALa1LATEDDEPfH 3.718 Fr. installed at the address shown and should not be used at any <br /> MINIMA THCWJESS WITHOUT REBAR 6.645 N <br /> . other location. <br /> SORT(M•12.6.1.7•.75/(.178.12w011-)) <br /> ACTUALTHCIPESS 18.000 N M�1E N cavil•'4 a••r's'b0••thisr.4.01,se• �, „r„of INSTALLATION ADDRESS: - <br /> CONCRETE 0.639 CU.Yo b a.ceom4 � <br /> 4�I :rjr4 i.. °°".,�,rt.lMaM"e.a�IL'I N.-, Yd a PROLOGIS <br /> ay d ad el totalatud~di� �did rat��anent rem 1200 INDUSTRY STREET BLD E <br /> i CAISSON EVERETT, WA 98203 <br /> MOMENT 2.456 Ff-h1P c a <br /> FORCE 0.642 IIP 1' " .1 <br /> REFERENCEBC1807.3.28.TAB_E1806.2 4 \�OQ WAS �� CLIENT. ..4, INTERNATIONAL PARKWAY <br /> ASSUME SOL CLASS K5 O_r:IL,I IH&C14 • '^ <br /> LATERAL PRESSURE-PSF/FT OF DEPTH 100.0 FSF/FT • Co�4 1 NCO �� P.O. BOX 9175 <br /> S1 311.1 *�y~ �+ 24 " AGI VIRGINIA BEACH, VA 23450 <br /> ,� 1/4 o a <br /> DEPTH 4.86? FT. Q <br /> DIA METER 2000 FT. ho f `I ; • • <br /> ( -= 3.827 Fr. _ f�,,:, .41,:.-'. �Vs A , LINK Engineering, L.L.C. <br /> [ CALC&ATED DEPTH' 4.602 Fr. • 11, A ..39681 �� �44: !.?,'lC / 135 South David Lone • Knoxville,Tennessee 37922 <br /> 2.414 FT. <br /> MINMUJ THCKNF-SS WITHOUT REAIFORCEM1Ei41 15.950 N F G\ * 1 Phone: (865) 539-4001•Fo1a (885)539-0851 <br /> SS/DIYAI+G� e q Online: www.linifengr.com <br /> ACTUALIXArtEIER 24.000 0,1 <br /> G ^�� / 3 BY: SR Project Number. <br /> n� 19-0053 <br /> CONCRETE 0.543 CU.YD. \ 1 [EWIRES 02/05/2020 I of3 B <br /> DATE: 01/22/19 DrawingNumber: <br /> B1633067 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.