Laserfiche WebLink
Lighting Summary LGT-SUM <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Info Project Title: Garden Fresh Server Room TI Date 2/14/2018 <br /> Compliance Applicant Information. Provide contact information for individual who can For Building Department Use <br /> forms do not respond to inquiries about compliance form information provided. <br /> require a Company Name: Jackson Main Architecture <br /> password to <br /> use. Company Address: 311 1st Avenue south <br /> Instructional and <br /> calculating cells Applicant Name: Gregg Percich <br /> are wife- <br /> protected. Applicant Phone: 206-324-4800 <br /> Applicant Email: gregg.percich@jacksonmain.com <br /> Project Description <br /> ❑New Building Q Addition FA Alteration CI Plans Included <br /> Include PROJ-SUM form(included in envelope forms workbook) faith lighting complliance forms. <br /> Building Additions Compliance Method 1 Interior lighting Exterior lighting <br /> Lighting systems in addition area comply with all applicable CI ❑ <br /> provisions as a stand alone new construction project <br /> Referto Section C502.2.6 for additional ._.__......__._.._.._._..._......__..................._.__._._..........__..-._.____.__..__...._.._........._..__.__.._._....... <br /> requirements. Lighting systems in addition are combined with existing i ❑ ❑ <br /> building lighting systems to demonstrate compliance <br /> Addition is combined with existing: <br /> For interior lighting projects,include new+existing interior lighting fixture wattage in Proposed <br /> Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. <br /> For exterior lighting projects,include new+existing exterior lighting fixture wattage in Proposed <br /> Tradable and Proposed Non-Tradable Lighting Wattage tables in LTG-EXT form. <br /> Interior and Exterior Lighting Power 1 Interior lighting i Parking garage Exterior lighting <br /> Lighting Alterations 50%or more of existing are replaced <br /> Select all Lighting Power and Lighting <br /> Control elements that apply to the scope Less than 50%of existing are replaced GA 0 0 <br /> ofthe retrofit project.If projectincludesa .....__...-.._._._._._.._.._-_._.__.._______.._._....._.____..-._........_.._....___1......_...._._._.......___.____.__.._...._.j._._.._._.___._.._....-...._...........___.____....._......_...._............._.-.._._._._. <br /> combination of spaces where less than Lamp and/or ballast replacement only <br /> 50%of the existing fixtures are replaced --existing total wattage not increased ❑ ❑ ❑ <br /> in some spaces,and 50%or more of the <br /> fixtures are replaced in others, then 50%or more replaced-Total lighting power of new+existing-to-remain fixtures shall comply with <br /> provide separate lighting power total LPA per Sections C405.4.2 and C405.5.2. Include new+existing-to-remain fixtures in <br /> compliance forms for the two retrofit Proposed Lighting Wattage table in LTG-INT-BLD,LTG-INT-SPACE or LTG-EXT form. <br /> conditions.Spaces undergoing the same Less than 50%replaced-Total lighting power of new+existing-to-remain fixtures shall not exceed <br /> type of retrofit may be combined into one the total lighting power prior to alteration, Include new+existing-to-remain fixtures in the Proposed <br /> lighting power compliance form. Lighting Wattage table in LTG-INT-BLD,LTG-INT-SPACE or LTG-EXT form. <br /> 50%threshold applies to number of luminaires for interior spaces and parking garages,and total <br /> Refer to Section C503.6 for additional installed wattage for exterior luminaires. <br /> requirements. { <br /> Lighting Controls i Interior lighting 1 Parking garage i Exterior lighting <br /> All alteration lighting controls shall be New wiring installed to serve added I <br /> commissioned per C408.3. fixtures and/or fixtures relocated to 1 ❑ ❑ ❑ <br /> new circuit(s) <br /> New or moved lighting panel j 0 0 0 <br /> Interior space is reconfigured - i ,,� <br /> luminaires unchanged or relocated ❑ r > d <br /> , <br /> New wiring or circuit -For interior lighting,provide required manual controls per C405.2.3, <br /> occupancy sensor controls per C405.2.1,daylight responsive controls per C405.2.4 and application <br /> specific lighting controls per C405.2.5.For exterior lighting,provide required controls per C405.2.7. <br /> 0 No changes are being made to <br /> the interior or exterior lighting New or moved panel-Provide all applicable lighting controls as noted for New Wiring and automatic <br /> systems and existing space time switch controls per C405.2.2. <br /> uses and configuration are not Reconfigured interior space-Provide all required lighting controls that apply to a new interior <br /> changed. space.Application specific lighting control provisions per C405.2.5 do not apply to reconfigured <br /> Change of Space Use ❑ Existing interior lighting systems in areas under-going a change in space use are upgraded to <br /> comply with LPAs for the new space types per Tables C405.4.2(1)or C405.4.2(2). <br /> Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage <br /> table in LTG-INT-BLD or LTG-INT-SPACE form. <br /> 0 <br />