My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1505 INDUSTRY ST 2019-07-24
>
Address Records
>
INDUSTRY ST
>
1505
>
1505 INDUSTRY ST 2019-07-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/24/2019 7:56:06 AM
Creation date
7/24/2019 7:56:05 AM
Metadata
Fields
Template:
Address Document
Street Name
INDUSTRY ST
Street Number
1505
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Garden Fresh Server Room TI Date 2/14/2018 <br /> Calculation a a Addition - Addition For Building Department Use <br /> Area"T" stand alone +existing <br /> Spaces where<50%of d Spaces where z 50%of d <br /> luminaires are replaced luminaires are replaced <br /> LPA 0 Standard a Additional Efficiency Package Option 4 <br /> Calculation C406.3 Reduced Interior Lighting <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE' <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type HeightNOTE2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Total Area <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Enter Total Existing Lighting Watts(prior to Alteration) <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY"orE8 Allowed Watts <br /> Proposed Lighting Wattage raTE3 <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE4,5'a Fixtures Fixture"3TE7 Proposed <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts <br /> Interior Lighting Power Allowance <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included). <br /> For <br /> track lighting, list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as <br /> existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage). For low <br /> voltage <br /> lighting, enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or <br /> 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.