6/20/2019 Page 1 <br /> City of Everett <br /> 1:45:21PM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. E1906-083 Site Address 2217 JADE AVE <br /> Applied 6/13/2019 Applicant Lot <br /> Approved 6/13/2019 Owner NOLLSCH DEREK W Block <br /> Issued 6/13/2019 Contractor PREMIER ELECTRICAL SRVCS INC Tract <br /> Parent Permit No. Description REPLACE PANEL <br /> Notes <br /> Scheduled Completed Type Inspector Result Remarks Inspector's Comments <br /> 6/14/2019 6/14/2019 ELEC 08-OTHER SKB NO ACCESS eTRAKiT Inspection 6/13/2019 7:01 PM Darren Maybruck <br /> Request Panel and meter socket upgrade <br /> Contact Name:Darren Maybruck <br /> Site Address:2217 JADE AVE <br /> Phone:3604215230 <br /> e-Mail:darrenm@premierelectricalsvc.com <br /> 6/18/2019 6/18/2019 ELEC 09-FINAL SKB CORRECTION (6/18/2019 2:22 PM SKB) <br /> See notes above. <br /> 6/18/2019 6/18/2019 ELEC 05-SERVICE SKB PARTIAL APPR 425-367-8407 Derek <br /> (6/18/2019 2:22 PM SKB) <br /> Install main bonding jumper The screw is <br /> missing.The water pipe grounding <br /> electrode conductor has to be Number for <br /> copper.Bond the service mast with a <br /> number 4 cu as it is isolated by the PVC. <br /> 6/19/2019 6/19/2019 ELEC 09-FINAL SKB APPROVAL 425-367-8407 Derek <br /> 6/19/2019 6/19/2019 ADMIN USE AKH APPROVAL <br /> ONLY** <br /> INSP12 CI I YSTE,'> <br />