6/17/2019 Page 2 <br /> City of Everett <br /> 10:50:10AM <br /> INSPECTION ACTIVITY REPORT <br /> 5/29/2019 5/30/2019 ELEC 09-FINAL MCB CORRECTION eTRAKiT Inspection 5/28/2019 6:18 PM Joel Cummings <br /> Request Please come in afternoon if possible. <br /> Flexible conduit being attached in morning, <br /> should be done by noon. <br /> Contact Name:Joel Cummings <br /> Site Address: 1518 MADISON ST <br /> Phone:2537206589 <br /> e-Mail:cummings.joel@gmail.com <br /> (5/30/2019 1:13 PM MCB) <br /> Gfci protection in Kitchen,Arc fault <br /> breakers where required.Complete <br /> corrections per inspections. <br /> 6/3/2019 6/3/2019 ELEC 09-FINAL SKB CORRECTION eTRAKiT Inspection 5/31/2019 3:56 PM Joel Cummings <br /> Request Arc faults installed.GFCI in kitchen <br /> functional.Please come early if possible. <br /> Trying to close the sale same day. <br /> Contact Name:Joel Cummings <br /> Site Address: 1518 MADISON ST <br /> Phone:2537206589 <br /> e-Mail:cummings.joel@gmail.com <br /> (6/3/2019 12:53 PM SKB) <br /> All receptacles are to be temporary system <br /> tight.All newly wired receptacles on the <br /> kitchen countertop are to be grounded. <br /> Provide a dedicated circuit for the laundry <br /> or bath circuits as they are not allowed to <br /> share one circuit.The waters heater circuit <br /> has to be#10 all the way to the water <br /> heater.All junction boxes in the attic have <br /> to be above the insulation line.NM cable <br /> cannot be installed inside the conduit <br /> outside feeding the garage.The garage is 14 <br /> gage wire and cannot be on a 20 amp <br /> circuit.You cannot fuse the neutral feeding <br /> the garage.Install the outside light by the <br /> man door so the cable is not expose on his <br /> end.Install box extenders for the boxes are <br /> not flush to the wall or least within 1/4 inch <br /> of being flush.Ground the dishwasher and <br /> verify that it is on a dedicated circuit not on <br /> with the small appliance circuits. <br /> 6/5/2019 6/5/2019 ELEC 09-FINAL SKB NOT READY eTRAKiT Inspection 6/4/2019 4:12 PM Joel Cummings <br /> Request Work should be done around noon.Please <br /> come after 1 pm in case of setbacks.I <br /> would like to meet you at the property if <br /> possible.Thanks. <br /> Contact Name:Joel Cummings <br /> Site Address: 1518 MADISON ST <br /> Phone:2537206589 <br /> e-Mail:cummings.joel@gmail.com <br /> 6/6/2019 6/6/2019 ADMIN USE KLC APPROVAL <br /> ONLY** <br /> 6/6/2019 6/6/2019 ELEC 09-FINAL SKB APPROVAL eTRAKiT Inspection 6/5/2019 1:40 PM Joel Cummings <br /> Request Please come before 10 AM if possible <br /> Contact Name:Joel Cummings <br /> Site Address: 1518 MADISON ST <br /> Phone:2537206589 <br /> e-Mail:cummings.joel@gmail.com <br /> INSP12 C SYSTEMSRW <br />