DESIGN LOADS: GENERAL NOTES: %i <br /> 6 r s <br /> 1. BUILDING CODES 1. IMPORTANT: CONTRACTOR IS TO READ ALL NOTES AND REVIEW ALL ■at. <br /> a� rrir <br /> DETAILS PRIOR TO BEGINNING CONSTRUCTION.CONTRACTOR banteI C.Smith,PE <br /> 1.1 WA:2015 INTERNATIONAL RESIDENTIAL CODE w!WASHINGTON RESPONSIBLE FOR VERIFYING LOCAL FROST DEPTH AND VERIFYING THAT Consulting Engineers <br /> STATE AMENDMENTS. THE FOOTING DEPTH NOTED ON THE DRAWINGS ARE ADEQUATE.IF LOCAL 13237 Melvin Arnold Road <br /> 1.2 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER FROST DEPTH IS MORE SHALLOW THAN WHAT IS SPECIFIED ON THE Raleigh,NC 27613 <br /> STRUCTURES,ASCE 7-05(UNLESS ASCE 7-10 SPECIFIED PER CODE). DRAWINGS,CONTRACTOR TO GO BY DEPTH ON DRAWINGS. P:919.844.6050 ext 1 <br /> F:877.841.6050 <br /> 2. THE DESIGN PROFESSIONAL WHOSE SEAL APPEARS ON THESE DRAWINGS IS E:decks6'dansmithpe.com <br /> 2. DESIGN CRITERIA THE STRUCTURAL ENGINEER OF RECORD("SER")FOR THIS PROJECT, NO RESIDENTIAL <br /> OTHER PARTY MAY REVISE,ALTER,OR DELETE ANY STRUCTURAL ASPECTS <br /> 2.1 UNLESS OTHERWISE NOTED ON SHEET S-2(aka FRAMING PLAN), OF THESE CONSTRUCTION DOCUMENTS WITHOUT WRITTEN PERMISSION OF FREE <br /> NO HOT TUBS,SPAS,SAUNAS,BRICK/MASONRY FIRE PLACES, DANIEL C.SMITH PE CONSULTING ENGINEERS AND THE"SER". <br /> BARBECUE PITS,ETC.,ARE TO BE SUPPORTED ON THE DECK STANDING <br /> STRUCTURE. 3; "SER"IS NOT RESPONSIBLE FOR CONSTRUCTION SEQUENCES,METHODS,OR DECK <br /> TECHNIQUES IN CONNECTION WITH THE CONSTRUCTION OF THIS o T,,,,;R„PI CO,,t,m,;,,,,;",,r, <br /> 2.2 LIVE LOAD: 60 PSF STRUCTURE. "SER"WILL NOT BE HELD RESPONSIBLE FOR THE <br /> 2.3 DEAD LOAD: 10 PSF CONTRACTOR'S FAILURE TO CONFORM TO THE CONTRACT DOCUMENTS, <br /> 2.4 DL+LL: 70 PSF SHOULD ANY NON-CONFORMITIES OCCUR. <br /> 2.5 BASIC WIND SPEED: 110 MPH <br /> 2.6 SNOW LOAD(g): 25 PSF 4. VERIFICATION OF ASSUMED FIELD CONDITIONS IS NOT THE RESPONSIBILITY <br /> 2.7 EXPOSURE C OF"SER". CONTRACTOR SHALL VERIFY THE FIELD CONDITIONS FOR <br /> 2.8 WIND IMP.FACTOR 0.87(ASCE 7-05) ACCURACY BEFORE CONSTRUCTION BEGINS. <br /> RISK CATEGORY I(ASCE 7-10) <br /> 2.7 CHECKED LOAD FOR COMBINATIONS:DL+WL(75%) 5. THIS STRUCTURE AND ALL CONSTRUCTION SHALL CONFORM TO ALL <br /> 2.8 CHECKED LOAD FOR COMBINATIONS:DL-WL(UPLIFT) APPLICABLE SECTIONS OF THE INTERNATIONAL RESIDENTIAL CODE AND <br /> ANY LOCAL LAWS WHERE THE STRUCTURE IS TO BE CONSTRUCTED. <br /> 3. DESIGN NOTES <br /> 6. NO DECK ATTACHMENT ALLOWED TO HOUSE BAND ON SECOND FLOOR,or <br /> 3.1 WHERE THE SNOW LOAD(g),DETERMINED BY LOCAL HIGHER,THAT IS ON A CANTILEVERED OVERHANG. <br /> ENFORCEMENT AGENCY,EXCEEDS 40 PSF,DECK HAS BEEN <br /> DESIGNED TO ACCOUNT FOR INCREASED LOADS. 7. INSTALL EITHER GALVANIZED OR VINYL FLASHING BETWEEN THE DECK 4.0 <br /> SYMBOLS AND HOUSE PER CODE REQUIREMENTS. 'L$ cu <br /> N <br /> TERMINOLOGY 8. STAIRWAYS SHALL HAVE A NEW OR EXISTING LIGHT SOURCE LOCATED IN Ct CO <br /> GIRDER aka BEAM <br /> 0 DIAMETER THE IMMEDIATE VICINITY OF THE TOP OF EXTERIOR STAIRS. LIGHT SHALL GU O1 <br /> bt CI) <br /> BAND BOARD aka RIM JOIST or "#'DETAIL NUMBER OPERATE EITHER WITH CONTINUOUS ILLUMINATION,BY AUTOMATIC <br /> SKIRT BOARD or0 CONTROL(E.G.,MOTION DETECTION),OR WITH A SWITCH INSIDE THE !dt a.)RIM PLATE "s"SHEET NUMBER DWELLING.[2012 IRC R303.7 or EQUIVALENT CODE PER STATE) <br /> RIM JOIST OUTER-MOST JOIST or '�-rte'' CROSS BRACING 9. ALL SECTIONS AND DETAILS ARE TYPICAL AT SIMILAR LOCATIONS AND (U •••JOIST w!RIM TRACK WHERE APPLICABLE. DETAILS APPLY ONLY TO EXACT CONDITIONS <br /> SHOWN. DETAILS ARE NOT TO BE MODIFIED FOR SIMILAR CONDITIONS, Q <br /> ABBREVIATIONS EXCEPT DETAILS MAY BE MIRRORED TO MATCH FIELD CONDMONS. t--I <br /> APPROX. APPROXIMATELY <br /> EQUIV. EQUIVALENT 10. DANIEL C.SMITH PE CONSULTING ENGINEERS AND THE"SER"ASSUME NO � N w <br /> 9 FLOOR JOIST LIABILITY FOR DETAILS ADAPTED TO SIMILAR CONDITIONS. <br /> F <br /> w " ... FTG FOOTING 11. DANIEL C.SMITH PE CONSULTING ENGINEERS AND THE"SER"ASSUME NO <br /> GALV. GALVANIZED DCSPE 4: 18-D-0128a <br /> �4. �': ",° H . HOT DIPPED LIABILITY FOR WATER TIGHT INTEGRITY. CONTRACTOR SHALL PROVIDE <br /> FLASHING TO ADJACENT STRUCTURES PER ACCEPTED PRACTICE AND Drawn By: BML <br /> r® .DHDG HOT DIPPED GALVANIZED METHODS. Revision History: <br /> + OPT. OPTIONAL 01-23-2019 <br /> J PT PRESSURE TREATED <br /> I `Z 12. OWNER/CONTRACTOR TO CONFIRM DECK DESIGN DOES NOT INTERFERE <br /> 'rr R S RING SHANK WITH EGRESS PATHWAYS,ELECTRICAL CLEARANCES,WINDOW GLAZING, X <br /> For Construction <br /> SIM. STvIILAR <br /> S.S. NLE ETC.or SHALL MAKE MODIFICATIONS TO EXISTING STRUCTURES AS <br /> 011.1:4':`'.'AO z A'' TYP TYPICAL APPROPRIATE STEEL APPROPRIATE TO MEET LOCAL CODE. Not for Construction <br /> ° ' r ' UNO UNLESS NOTED OTHERWISE 13. THESE PLANS ARE VALID FOR PERMITTING WITHIN 12 MONTHS OF THE aShe�eTt <br /> V.I.F. VERIFY IN FIELD SEAL DATE. \ 1 V-1 <br /> "�I of 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.