Crazing(7x magnification) -- None None None <br /> Linear Dimensional Change,% D1204 0.5%max. 0.31 0.24 <br /> Weight Change After Immersion in Water,% D570 ±3.0%max. 2.9 2.5 <br /> Static Puncture Resistance,lbf(kg) D5602 33(15) Pass Pass <br /> Dynamic Puncture Resistance,ft-lbf(J) D5635 14.7(20) Pass Pass <br /> Recycled Content -- -- 9%Pre-consumer,1%Post-consumer <br /> *Results may differ based upon statistical variations depending upon mixing methods and equipment,temperature,application <br /> methods,test methods,actual site conditions,and curing conditions. <br /> 1 M.D.=Machine Direction,C.M.D.=Cross Machine Direction <br /> 2 Failure occurs through membrane rupture not seam failure. <br /> INITIAL 3-YEAR INITIAL SOLAR 3-YEAR SOLAR <br /> INITIAL SOLAR 3-YEAR SOLAR <br /> z THERMAL REFLECTANCE REFLECTANCE <br /> REFLECTANCE1 REFLECTANCE', THERMAL <br /> EMITTANCE EMITTANCE2 INDEX INDEX <br /> Sikaplan Fastened <br /> EnergySmart White- 0.83 0.643 0.89 Pending 104 Pending <br /> 45 mil <br /> Sikaplan Fastened <br /> EnergySmart White- 0.85 0.663 0.89 Pending 107 Pending <br /> 60 mil <br /> Sikaplan Adhered <br /> EnergySmart Reflective 0.73 0.654 0.89 0.884 90 784 <br /> Gray-60 mil <br /> Sikaplan Fastened <br /> EnergySmart Tan- 0.72 0.654 0.89 0.884 88 784 <br /> 60 mil <br /> 1Solar Reflectance testing according to ASTM C1549 <br /> 2Thermal Emittance testing according to ASTM C1371,Slide Method <br /> 3 Derived using the California Title 24 calculation method for aged solar reflectance per Section 110.8(1)2.of the 2013 Building Energy <br /> Efficiency Standard,page 102. <br /> 4 CRRC Rapid Ratings:These are interim laboratory-aged values that simulate weathered values.These values will be replaced with the <br /> measured three-year aged values upon completion of the weathering process.SRI values calculated using Rapid Ratings may change <br /> once the aged rating replaces the interim rating. <br /> SYSTEM INFORMATION <br /> APPLICATION Sikaplan Fastened EnergySmart Roof Membrane is installed on acceptable substrates <br /> and fastened to the roof deck using the approved attachment method. The <br /> membrane is heat-welded together by trained mechanics using hot-air welding <br /> equipment. Sikaplan Fastened EnergySmart Roof Membrane can be used for <br /> flashings on Sikaplan Fastened roof projects. <br /> AVAILABILITY From Sika Authorized Applicators when used within Sikaplan roofing systems. <br /> MAINTENANCE Standard maintenance of roofs should include regular inspection of flashings,drains <br /> and termination sealants at least twice a year and after each storm. <br /> WARRANTY Upon successful completion of the installed roof by the Sika Authorized Applicator, <br /> Sika Corporation will provide a warranty to the Building Owner via the Sika <br /> Authorized Applicator. <br /> 017 <br /> oradart Data Sheet North America A <br />