GENERAL POWER AND �ONTROL LIGHTING FIXTURES ENERGY SUB-METERING SYSTEM <br /> 1 � FLAG NOTE, IN CONSTRUCTION NOTE. LIGHTING FIXTURES: UPPER CASE ALPHA-NUMERIC CHARACTER INDICATES FIXTURE TYPE. � SUB-METERING NODE <br /> � LOWER CASE ALPHA-NUMERIC CHARACTER INDICATES CIRCUIT NUMBER AND PHASE FED FROM. XXX XXX SIGNIFIES METERING TYPE: <br /> � BOAT NOTE, IN GENERAL NOTE. UPPER CASE ALPHA-NUMERIC CHARACTER IN PARENTHESIS INDICATES RELAY NUMBER. . <br /> 52 MEDIUM VOLTAGE CIRCUIT BREAKER DRAWOUT TYPE � LOWER CASE LETTER INDICATES SWITCH LEG. VFD DIRECT CONNECTION TO VFD VIA COMMUNICATIONS <br /> "NL" INDICATES NIGHT LIGHT OPERATION CIRCUIT NOT SWITCHED � <br /> DETAIL NUMBER � � )• PROTOCOL <br /> � CT CURRENT TRANSFORMER-BASED STAND ALONE METER <br /> 1E10 E510 �`�- DETAILSHEET r� FUSE � WITH COMMUNICATIONS PROTOCOL. <br /> STRUCTURE MOUNTED LED HIGH BAY FIXTURE. EACH FIXTURE SHALI� INCLUDE MTR FLUID FLOW METER. <br /> CALLOUT SHEET A QUICK DISCONNECT AND IN-LINE FUSE. <br /> �a� DOOR TAG STRUCTURE MOUNTED LED HIGH BAY FIXTURE (EMERGENCY). EACH FIXTURE SM SUB-METERING GATEWAY <br /> / AT LOW VOLTAGE CIRGUIT BREAKER. O SHALL INCLUDE A QUICK DISCONNECT AND IN-LINE FUSE. <br /> AMP FRAME/AMP TRIP. <br /> I—o---i INDUSTRIAL FLUORESCENT/LED LIGHTING FIXTURE. <br /> �-� INDUSTRIAL FLUORESCENT/LED LIGHTING FIXTURE (EMERGENCY) COLO R CO D ES <br /> 25 SYNCHRONISM - RELAY <br /> 0 WALL/RECESSED/SURFACE MOUNTED FLUORESCENT LIGHTING FIXTURE. <br /> D I ST R I B U T I O N SYST E M PHASE 480Y/277 VAC POWER CABLES 208Y/120 VAC POW ER CABLES <br /> 27 UNDER VOLTAGE RELAY �E� WALL/RECESSED/SURFACE MOUNTED FLUORESCENT LIGHTING FIXTURE (EMERGENCY) A-PHASE (LEFT BUS IN PNL) BROWN BLACK <br /> i DISTRIBUTION PANELBOARD 480Y/277V B-PHASE (CENTER BUS IN PNL) ORANGE RED <br /> RECESSED MOUNTED LED LIGHTING FIXTURE GPHASE (RIGHT BUS IN PNL) YELLOW BLUE <br /> � POWER PANEL, 208Y/120V 5� INSTANTANEOUS/TIME OVERCURRENT � NEUTRAL GRAY WHITE <br /> RELAY EQUIPMENT GROUND GREEN GREEN <br /> � SPECIAL PANEL AS NOTED Q RECESSED MOUNTED LED LIGHTING FIXTURE (EMERGENCY) ISOLATED GROUND GRN/YEL* GRN/YEL* <br /> 50N "` GREEN WITH YELLOW **TI BUILDOUT ONLY- PROVIDE <br /> � GROUND ROD, "TW" INDICATES TEST WELL 51N INSTANTANEOUS/TIME NEUTRAL 0 EXTERIOR WALL PACK(EMERGENCY} 5 <br /> TRACER NUETRAL WITH COLOR TRACER TO IFC TI <br /> TW OVERCURRENT RELAY MATCH PHASE <br /> POWER FACTOR CORRECTION CAPACITORS ��, WALL OR CEILING EXIT SIGN. FIXTURE SHALL BE WIRED AHEAD OF LOCAL SWITCHES.ARROW <br /> (4)#1,#6G,1-1/2"C �_ AS SHOWN DENOTES DIRECTION OF EGRESS, SOLID QUADRANT INDICATES FACE. <br /> ���_� HOME RUN-PANEL-CIRCUIT(EXAMPLE 2V57 ) CROSS MARKS �, (FUSED) <br /> 2V57-4BMA10/2,4,6 PNL-CKT �� CONTROL POWER TRANSFORMER L I G HT I N G CO N T RO LS PAN E L N O M E N C LATU R E <br /> INDICATE QUANTITY OF CONDUCTORS (SIZE NOTED) LONGER SLASH rY� <br /> INDICATES NEUTRAL WIRE(IF REQUIRED). IF UNMARKED INSTAL,L 3#12 AWG LIGHTING CONTROL SWITCHES AND OCCUPANCY SENSORS:ADDITIONAL LOWER CASE XE 4 V58-3A M A2-1-D <br /> IN 3/4" CONDUIT. REVERSED SLASH INDICATES GROUND WIRE. � POTENTIAL TRANSFORMER LETTER INDICATES SWITCH LEG. - <br /> CONDUIT EXPOSED (RIGID METAL) � SINGLE POLE TOGGLE WALL SWITCH — SUFFIX"D" INDICATES DISTRIBUTION PANEL <br /> CURRENT TRANSFORMER. MR INDICATES <br /> - - � �- - - - -- -� -- CONDUIT EMBEDDED IN CONCRETE OR BELOW GRADE � MR MULTI-RATIO �3 THREE-WAY TOGGLE WALL SWITCH SUFFIX"-1, -2, ETC." USED TO INDICATE MULTIPLE PANELS AT SAME LOCATION WITH SAME VOLTAGE AND FED FROM SAME VAULT <br /> FLEXIBLE METAL OR LIQUIDTIGHT FLEX METAL CONDUIT AS NOTED PM ALLEN-BRADLEY POWER MONITOR 5p00 SOS LINE-VOLTAGE OCCUPANCY SENSOR WALL SWITCH NEAREST COLUMN INTERSECTION , <br /> ^ CONDUIT TURNING UP q ANALOG AMMETER �'WP SINGLE POLE TOGGLE WALL SWITCH, WEATHERPROOF LOCATION OF PANEL WHEN NOT ON FIRST FLOOR: <br /> � � � <br /> XX�LV LOW-VOLTAGE, 2-BUTTON ON/OFF WALL SWITCH. SWITCH TO TIE TN1 =TUNNEL LEVEL 1 <br /> � CONDUIT TURNING DOWN AS AMMETER SWITCH INTO GE LIGHTSWEEP LIGHTING CONTROL PANEL(S)SERVING TN2 =TUNNEL LEVEL 2 <br /> RESPECTIVE AREA. REFER TO GE UGHTING LIGHTSW EEP CONTROL P=AUTOCLAVE PIT <br /> G GROUND WIRE (SIZE AS NOTED) DRAWINGS FOR MORE INFORMATION M = MEZZANINE <br /> VS VOLTMETER SWITCH U = LEVEL 2 <br /> G GROUND WIRE WITH EXOTHERMIC WELD CONNECTION WHERE SHOWN)FIRST DIGIT REPRESENTS FLOOR(U-2ND FLOOR, V- 3RD FLOOR) � V= LEVEL 3 <br /> � SECOND DIGIT SPECIFIES LIGHTWG CONTROL ZONE. SEE CONTROL.ZONE PLANS 2E8 C= CATWALK <br /> E EMERGENCY CIRCUIT AND 3E8 FOR ADDITIONAL INFORMATION. IFC TI RF = ROOF � <br /> � ANALOG VOLTMETER OC CEILING MOUNTED, LOW-VOLTAGE, _ <br /> DUAL TECHNOLOGY OCCUPANCY SENSOR WITH POWER PACK I VAULT <br /> L EXPOSED LIGHTNWG PROTECTION CONDUCTOR LCP POWER PACK: HUBBELL#UVPP OR APPROVED EQUAL (FOR EACH OCCUPANCY SENSOR) <br /> ROOMS: HUBBELL#OMNI-DT-500/100 OR APPROVED EQUAL(500/1000 SQ. FEET) <br /> J� JUNCTION BOX, SPECIAL (SIZE NOTED, "WP"-WEATHERPROOF) � SYSTEM GROUND CORRIDORS/TUNNELS: HUBBELL#OMNI-DT-200d OR APPROVED EQUAL (2,000 SQ. FEET) � VOLTAGE: ' <br /> 4 =480V, 3PH, 3W <br /> ��I PULL BOX(SIZE NOTED, "WP"-WEATHERPROOF) SUBSCRIPT INDICATES LOW VOLTAGE OCCUPANCY SENSOR WIRED BACK TO GE LIGHTING CONTROL PANEL 3 =480Y/277V, 3PH,4W <br /> ��' MOTOR STARTER(COMBINATION) INDICATED. 2 =208Y1120V, 3PH,4W OR 120i240V, 1 PH, 3W <br /> FT� FIELD TERMINAL BOX <br /> I/0 REMOTE I/O RACK L� MOTOR STARTER (MANUAL) � BUILDWG MOUNTED PHOTOCELL. PREFIX: <br /> ;V SOLENOID VALVE ZONE X `_�HB LOW-VOLTAGE, 2-BUTTON HIGH BAY LIGHTING WALL SWITCH WITH (BLANK) = NORMAL POWER PANEL <br /> PM POWER MONITOR DEVICE � pESIGNATED ZONE. SWITCH TO TIE INTO GE LIGHTSWEEP LIGHTWG � "I" = ISOLATED GND PANEL <br /> CONTROL PANEL(S)SERVING RESPECTIVE ZONES. BUTTONS SHALL "Z" =400 HZ PANEL <br /> 0 REMOTE CONTROL STATION (TYPE AS NOTED) 9 INCLUDE: 'OVERRIDE'AND 'UNASSIGNED'. REFER TO GE LIGHTING "XE"= EMERGENCY PANEL <br /> LIGHTSWEEP CONTROL DRAWWGS FOR MORE INFORMATION. "XL"= LEGALLY REQUIRED STANDBY PANEL <br /> °XS"= OPTIONAL STANDBY PANEL <br /> E Q U I P M E N T/D EV I C ES o EMERGENCY POWER SHUTDOWN AUTOCLAVE IFC � "XU" = UPS SYSTEM , <br /> ;'T 120 MINUTE TIMER WALL SWITCH <br /> �TF 3-COMPARTMENT POWER POLE WIRE MOLD 30TP-4 � 3 ��D SINGLE-POLE DIMMER WALL SWITCH Q <br /> � TRANSFORMER(CAPACITY, PHASE&VOLTAGE AS NOTED) `C� v <br /> NON-FUSED DISCONNECT SWITCH (ENCLOSED BREAKER OR MOLDED 1 2 (��,, 2-COMPARTMENT POWER POLE WIRE MOLD 30TP-3 <br /> XX/Y �� CASE SWITCH WHERE FAULT CURRENT EXCEEDS 10KA) � SYSTE M S <br /> FF NN EXP XX-SWITCH RATING ,gg SWITCH BYPASS DEVICE <br /> Y- NUMBER OF POLES � 4 � 0 ALUMINUM LADDER TYPE CABLE TRAY. SIZE& HEIGHT AS NOTED ON DRAWINGS. <br /> FF -FUSE RATING <br /> NN - ENCLOSURE TYPE � MANUAL CONTROLLER � 12"CABLE RUNWAY. <br /> EXP - EXPLOSION PROOF(CLASS I/DIV I UNLESS NOTED OTHERWISE) PANEL PAINT IFC <br /> CE COMMUNICATIONS ENCLOSURE. <br /> �� ENCLOSED CIRCUIT BREAKER �B TEST BLOCK <br /> 11 ' 2-Pt)RT MODULAR STAINLESS STEEL FRCEPLATE WITH (1)CAT 5e CABLE FROM "CE" OR"CR" INDICATED AND <br /> j � # (1)RJ-45 CONNECTOR FOR DATA OUTLET. PROVIDE BLANK COVER FOR UNUSED PORT. SUBSCRIPT INDICATES <br /> �� STARTER o� LOW VOLTAGE CIRCUIT BREAKER. NUMBER OF ACTIVE JACKS IF GREATER THAN 9. � � <br /> DRAWOUT TYPE , <br /> � MOTOR(SIZE AS NOTED) PANEL PAINT IFC � � � ,•/E STAINLESS STEEL FACEPLATE WITH MOUNTING STUD SCREWS, (1)CAT 5e UTP CABLE FROM 110 PUNCH- . <br /> 1 � DOWN BLOCKS INDICATED AND (1) RJ-45 CONNECTOR FOR ANALOG EMERGENCY PHONE OUTLET. MOUNT <br /> OUTLET AT 48"AFF, UON. COORDINATE EXACT LOCATION WITH OWNERS FIRE SAFETY REPRESENTATIVE <br /> �� GENERATOR,ALTERNATING CURRENT(VOLTAGE, KVA, � ELECTRICALLY OPERATED PRIOR TO ROUGH-IN. <br /> PHASES, FREQUENCY AS NOTED) _ <br /> � �✓� UNIT SUBSTATION TRANSFORMER �� CCTV OUTLET FOR INTERIOR CAMERA: SURFACE MOUNTED BOX INSTALLED ABOVE CEILING ON TILE BRIDGE <br /> � RECEPTACLE 20 AMP DUPLEX 2 POLE, 3 WIRE �/ ��r"�v� WITH 1-PORT MODULAR FACEP�ATE WITH (1)CAT 5e UTP CABLE AND (1) RJ-45 CONNECTOR. ROUT CATSe <br /> "'r CLASS I, DIVISION I EXPLOSIC?N PROOF GFCI 125V, 20A, 2P, 3W �� <br /> r� CABLE BACK TO "CE" OR"CR" INDICATED. CAMERA PROVIDED BY OTHERS. <br /> �EXP INTERLOCKING RECEPTACLE. CROUSE HINDS CPS152 (RECEPTACLE) 4y J � OVERLOAD RELAY 2-PORT MODULAR STAfNLESS STEEL FACEPLATE WITH (1)CAT 5e UTP CABLE FROM °CE" OR"CR" INDICATED <br /> AND GFS-1 (GFI MODULE) OR APPROVED ALTERNATE. 1 L� � � AND (1} CAT 5e CABLE FROM 110 PUNCHDOWN BLOCKS INDICATED AND (2) RJ-45 CONNECTORS. <br /> � A B O V E C O U N T E R R E C E P T A C L E 2 0 A M P D U P L E X, 2 P O L E, 3 W I R E $� LOCKOUT RELAY <br /> PB PULLBOX. SIZE AND TYPE AS NOTED ON DRAWWGS. <br /> IG 1 O G1 G2 KIRK KEY INTERLOCKS. SEE BOEING 0 <br /> !� ISOLATED GROUND RECEPTACLE,20AMP, DUPLEX, 2 POLE, 3 WIRE � STANDARDS NON- PAINTED FIRE RETARDANT PLYWOOD BACKBOARD. , <br /> �27 ) UNDERVOLTAGE RELAY 110 110 STYLE PUNCHDOWN BLOCKS. <br /> �`/ <br /> �GFI GROUND FAULT INTERRUPT RECEPTACLE, 20AMP, DUPLEX, 2 POLE, 3WIRE <br /> WP WP INDICATES WEATHER PROOF 46 REVERSE PHASE CURRENT RELAY CCVT CCTV ENCLOSURE FOR EXTERIOR CAMERA. <br /> ;� RECEPTACLE 20AMP 4-PLEX, 2 POLE, 3 WIRE 47 PHASE SEQUENCE VOLTAGE RELAY AMS <br /> AMS PANEL. <br /> ''�� RECEPTACLE, NEMA CONFIGURATION AS INDICATED . BR BADGE READER. � <br /> L6-20R C25 SYNCHRONIZING DEVICE <br /> JO JUNCTION BOX, FIELD SIZED PER NEC. BR PREPPED DOOR AND BADGE READER <br /> P <br /> _LA I I I LIGHTNING ARRESTER �s SUBSTATION POWER MONITOR NETWORK POINT OF CONNECTION. COORDINATE WITH OWNER FOR EXACT <br /> �FSD JUNCTION BOX, 120V CONNECTION FOR FIRE-SMOKE DAMPER � � LOCATION WITHIN SUBSTATION. <br /> �` PRIMARY MEDIUM VOLTAGE FUSED CEILING MOUNTED VOICE/DATA OUTLET WITH (1) CAT 5e CABLE AND (1) RJ-45 CONNECTOR TO"CE" OR"CR" ' <br /> �MOD JUNCTION BOX, 120V CONNECTION FOR MOTOR-OPERATED DAMPER R SWITCH � O INDICATED. LOCATE ADJACENT TO PROJECTOR POWER RECEPTACLE. <br /> J <br /> � CONNECTION TO EQUIPMENTAS INDICATED. � MEDIUM VOLTAGE CABLE TERMINATION a 2-PORT MODULAR OUTLET WITH (1)CAT 5e CABLE FROM "CE" OR"CR" INDICATED AND (1) RJ-45 CONNECTOR <br /> FOR DATA OUTLET. OUTLET IS MOUNTED WITHIN MULTI-PURPOSE POKE-THRU/FLOORBOX. REFER TO 208/120V REV 33 CHANGES ONLY �� <br /> IFC SPAR LAM (CELLS 4, 5 &6) POWER DRAWINGS FOR POKE THRU/FLOORBOX LOCATIONS. PROVIDE BLANK COVER FOR UNUSED PORT. <br /> MECHANICAL EQUIPMENT TAG. GF GROUND FAULT MONITOR SUBSCRIPT INDICATES NUMBER OF ACTIVE JACKS IF GREATER THAN 1. ��, CA�jA� <br /> � � 10 � �v�oF �As�,��� G <br /> �M MOTOR RATED SWITCH L.� � DMS DOOR MONITORING SYSTEM. <br /> SPD SURGE PROTECTIVE DEVICE �ie c pp�z �� ��'j � r <br /> � 7:57 Pi`�A 22`�1` 'GP�iTj <br /> � <br /> • � POKE THRU DEVICE-REFER TO DETAIL 3 ON SHEET E508-02-46 C� ' <br /> PT-X PT-1 -6" POWERIDATA/AV POKE THRU DEVICE V IFC TI <br /> PT-2 -8" POWER/DATA/AV POKE THRU DEVICE SG� STATIC GROUND RECEPTACLE SKIN LAM IFC �OO SW ��tI1 Stl"E'Et SU1�e' �O7 ���'���'c�STE�F� ���� <br /> �J � R@C1t011 WdSh� t0 `�`s'IONaL �� ' <br /> , trrg n 98057 ,� � <br /> � <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROUED DATE op WASy ACCEPTABILITY �gW 12i22/15 M <br /> �� '"�r THISDESIGNAND/OR �HE�KEo ELECTRICAL LEGEND w254s3�7 � 5 12i22/15 � <br /> 9 REVISION-REI.EASE 23(AUTOCLAVE IFCISKIN LAM IFCISPAR LAM 90P) JLM DFC 07128115 14 REVISION-RELEASE 33(PANEL PAINT IFC) JTD DFC 12/01/15 P JLM 12122115 SHEET u� <br /> — 5 � SPECIFICATION IS APPROVED .- <br /> BRPH ARCHITECTS ENGINEER TITLE O <br /> 10 REVISION-RELEASE 24(SPAR LAM IFG!PANEL PAINT 30P) JTD DFC 08111/15 15 REVISION-RELEASE 33(PANEL PAINT IFC} JTD DFC 12122115 � ENciNEERsiNC. APPROVEO BY DEPT. DATE DFC 12/22115 BOEING 777X CWC BUILDING <br /> �o��� � <br /> 11 REVISION-RELEASE 27(PANEL PAINT 60P) JTD DFC 09/22/15 6 REVISION-RELEASE 19 MXS DFC 06I02115 No.3�s� cHEctce� E O N <br /> � AF/DS �2�0���5 BUILDING 40'�V � <br /> 12 REVISION-RELEASE 29 JTD DFC 10120/15 7 REVISION-RELEASE 20 MXS DFC 06116/15 mP,� , ��� APPROVED �OB No. COMP NO. � <br /> cqTF OF AU'(N��\�P APPROVED 12101l15 ow�No. 40-58-EO m . <br /> 13 REVISION-RELEASE 30 JLM DFC 11/03/15 8 REVISION-RELEASE 21 (AUTOCLAVE 100P) RER DFC 06130/15 �� �ELECTRICAL MASTER EVERETT, WA 40-58-EO <br />